Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
JACC Cardiovasc Interv ; 14(5): 531-538, 2021 03 08.
Artículo en Inglés | MEDLINE | ID: mdl-33582086

RESUMEN

OBJECTIVES: The aim of this study was to investigate the online assessment feasibility of aortography using videodensitometry in the catheterization laboratory during transcatheter aortic valve replacement (TAVR). BACKGROUND: Quantitative assessment of regurgitation after TAVR through aortography using videodensitometry is simple, reproducible, and validated in vitro, in vivo, in clinical trials, and in "real-world" patients. However, thus far the assessment has been done offline. METHODS: This was a single center, prospective, proof-of-principle, feasibility study. One hundred consecutive patients with aortic stenosis and indications to undergo TAVR were enrolled. All final aortograms were analyzed immediately after acquisition in the catheterization laboratory and were also sent to an independent core laboratory for blinded offline assessment. The primary endpoint of the study was the feasibility of the online assessment of regurgitation (percentage of analyzable cases). The secondary endpoint was the reproducibility of results between the online assessment and the offline analysis by the core laboratory. RESULTS: Patients' mean age was 81 ± 7 years, and 56% were men. The implanted valves were either SAPIEN 3 (97%) or SAPIEN 3 Ultra (3%). The primary endpoint of online feasibility of analysis was 92% (95% confidence interval [CI]: 86% to 97%) which was the same feasibility encountered by the core laboratory (92%; 95% CI: 86% to 97%). Reproducibility assessment showed a high correlation between online and core laboratory evaluations (R2 = 0.87, p < 0.001), with an intraclass correlation coefficient of 0.962 (95% CI: 0.942 to 0.975; p < 0.001). CONCLUSIONS: This study showed high feasibility of online quantitative assessment of regurgitation and high agreement between the online examiner and core laboratory. These results may pave the way for the application of videodensitometry in the catheterization laboratory after TAVR. (Online Videodensitometric Assessment of Aortic Regurgitation in the Cath-Lab [OVAL]; NCT04047082).


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Aortografía , Estudios de Factibilidad , Humanos , Masculino , Estudios Prospectivos , Diseño de Prótesis , Reproducibilidad de los Resultados , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA