Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Eur J Ophthalmol ; 29(1): 57-60, 2019 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-29587491

RESUMEN

PURPOSE:: To introduce a new technique of short tunnel small flap graft-free glaucoma drainage device implantation and report our early experience. METHODS:: In a retrospective study, patients with uncontrolled primary open-angle glaucoma underwent short tunnel small flap graft-free Ahmed glaucoma valve implantation. In this technique, plate is sutured 8-10 mm posterior to the limbus and a partial thickness flap is made at 1 or 11 o'clock position, 1 mm posterior the limbus. Tube was passed through a tunnel immediately anterior to the plate into the proximal edge of the flap and then inserted into the anterior chamber via a route underneath the flap. Flap then covered the distal end of the tube and conjunctiva was sutured. Patients were followed for a minimum of 12 months for any sign of tube exposure and rise of intraocular pressure. RESULTS:: A total of 16 consecutive patients with refractory primary open-angle glaucoma and uncontrolled intraocular pressure were included in this study. Mean age of participants was 59 ± 8.3 years and nine (56%) were male. Mean intraocular pressure at the time of presentation was 26 ± 6.2 mm Hg, which dropped to 16 ± 4.5 at 12 months postoperative follow-up. The number of medications at baseline was 3 ± 1 eye drops, which was decreased to 1 ± 1.2 at 12 months. There were no conjunctival and flap-related complications or any sign of tube exposure during 1-year postoperative period. CONCLUSION:: Short tunnel small flap graft-free glaucoma drainage device implantation technique combines advantages of both tunneling and flap techniques. Also, it may result in better tube positioning and more favorable cosmetic outcomes.


Asunto(s)
Implantes de Drenaje de Glaucoma , Glaucoma de Ángulo Abierto/cirugía , Implantación de Prótesis/métodos , Esclerótica/cirugía , Colgajos Quirúrgicos , Cámara Anterior/cirugía , Conjuntiva/cirugía , Drenaje , Femenino , Glaucoma de Ángulo Abierto/fisiopatología , Humanos , Presión Intraocular/fisiología , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/prevención & control , Periodo Posoperatorio , Estudios Retrospectivos , Tonometría Ocular
2.
Int Ophthalmol ; 38(1): 145-150, 2018 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-28054211

RESUMEN

PURPOSE: To describe our experience with exchanging sulcus-fixated single-piece intraocular lens (IOL) with 3-piece IOLs for management of pigmentary glaucoma. METHOD: In this retrospective study, records of patients who underwent sulcus-fixated single-piece IOL exchanged with 3-piece IOLs were retrieved, and demographic and baseline data of patients, type of IOL, pre- and post-IOL exchange BCVA, IOP, number of anti-glaucoma medications, and optic nerve head examination were documented. Baseline and final examinations were analyzed and compared. RESULTS: Mean age of the patients was 59 ± 10 years, and 5 (41.6%) were female. Mean interval between primary cataract extraction operation and IOL exchange was 17 ± 5 months. Nine patients received in sulcus implantation of Alcon SA60AT, and three patients had SN60WF model at the end of primary surgery. BCVA changed insignificantly from 0.06 ± 0.06 logMAR to 0.06 ± 0.06 after IOL exchange. (P = 0.22) IOP was controlled in 8 cases (66.6%), but four cases (33.3%) needed glaucoma surgery to further control glaucoma condition. IOP decreased significantly from preoperative 17 ± 3 to 14 ± 1 mmHg postoperatively. Patients with advanced age and higher baseline IOP were more likely to undergo glaucoma surgery after IOL exchange. (P = 0.07 and 0.00, respectively). CONCLUSION: single-piece IOL exchange with 3-piece IOL dramatically decreases pigment release and reduces IOP. Those with advanced age and higher IOP are less likely to respond to IOL exchange and may need glaucoma surgery to control high intraocular pressure.


Asunto(s)
Cuerpo Ciliar/cirugía , Glaucoma de Ángulo Abierto/cirugía , Implantación de Lentes Intraoculares/métodos , Lentes Intraoculares , Adulto , Anciano , Femenino , Humanos , Presión Intraocular/fisiología , Masculino , Persona de Mediana Edad , Facoemulsificación , Estudios Retrospectivos , Agudeza Visual
3.
J Pediatr Hematol Oncol ; 31(2): 97-100, 2009 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-19194191

RESUMEN

OBJECTIVES: Pulmonary hypertension (PHT) is a life-threatening complication of sickle cell disease that occurs in 20% to 40% of adults. Measurement of maximal tricuspid regurgitant jet velocity (TRV) by echocardiography provides a noninvasive screening tool; TRV values > or =2.5 m/s are correlated with PHT and increased mortality. Our objective was to estimate the prevalence of PHT in our pediatric sickle cell population and its possible association with various clinical and laboratory findings, including obstructive sleep apnea and/or pulmonary dysfunction. STUDY DESIGN: Eligible children had measurement of the TRV. Clinical data were collected, including detailed history with a standardized sleep apnea questionnaire; those with suggestive histories had polysomonography. Pulmonary function was assessed using whole body plethysmography. RESULTS: Of 48 subjects (79% homozygous sickle cell anemia; median age 12 y; 11 receiving chronic transfusion) enrolled in the study, 4 (8.3%) had TRV >2.5 m/s; all had homozygous sickle cell anemia and 1 was receiving hydroxyurea after 3 years of transfusion for secondary stroke prevention. Subjects with elevated TRV had higher indirect bilirubin levels; we found no association between elevated TRV and obstructive apnea or pulmonary function abnormalities. CONCLUSIONS: Elevation of TRV was relatively uncommon in our pediatric patients as compared with prevalence reported in adults and may be associated with increased hemolysis. There was no association with obstructive sleep apnea or abnormal pulmonary function.


Asunto(s)
Anemia de Células Falciformes/complicaciones , Hipertensión Pulmonar/etiología , Bilirrubina/sangre , Niño , Recolección de Datos , Humanos , Prevalencia , Pruebas de Función Respiratoria , Apnea Obstructiva del Sueño , Insuficiencia de la Válvula Tricúspide
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA