Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Magn Reson Med ; 73(4): 1623-31, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-24844947

RESUMEN

PURPOSE: High-resolution myocardial perfusion analysis allows for preserving spatial information with excellent sensitivity for subendocardial ischemia detection. However, it suffers from low signal-to-noise ratio. Commonly, spatial averaging is used to increase signal-to-noise ratio. This bears the risk of losing information about the extent, localization and transmurality of ischemia. This study investigates spatial-averaging effects on perfusion-estimates accuracy. METHODS: Perfusion data were obtained from patients and healthy volunteers. Spatial averaging was performed on voxel-based data in transmural and angular direction to reduce resolution to 50, 20, and 10% of its original value. Fit quality assessment method is used to measure the fraction of modeled information and remaining unmodeled information in the residuals. RESULTS: Fraction of modeled information decreased in patients as resolution reduced. This decrease was more evident for Fermi and exponential in transmural direction. Fermi and exponential showed significant difference at 50% resolution (Fermi P < 0.001, exponential P =0.0014). No significant differences were observed for autoregressive-moving-average model (P = 0.081). At full resolution, autoregressive-moving-average model has the lowest fraction of residual information (0.3). Differences were observed comparing ischemic regions perfusion-estimates coefficient of variation at transmural and angular direction. CONCLUSION: Angular averaging preserves more information compared to transmural averaging. Reducing resolution level below 50% at transmural and 20% at angular direction results in losing information about transmural perfusion differences. Maximum voxel size of 2 × 2 mm(2) is necessary to avoid loss of physiological information due to spatial averaging.


Asunto(s)
Interpretación de Imagen Asistida por Computador/métodos , Angiografía por Resonancia Magnética/métodos , Imagen por Resonancia Cinemagnética/métodos , Isquemia Miocárdica/diagnóstico , Isquemia Miocárdica/fisiopatología , Imagen de Perfusión Miocárdica/métodos , Algoritmos , Humanos , Aumento de la Imagen/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Análisis Espacio-Temporal
2.
IEEE Trans Biomed Eng ; 61(9): 2499-2506, 2014 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-24833413

RESUMEN

First-pass perfusion cardiac magnetic resonance(CMR) allows the quantitative assessment of myocardial blood flow(MBF). However, flow estimates are sensitive to the delay between the arterial and myocardial tissue tracer arrival time (tOnset) and the accurate estimation of MBF relies on the precise identification of tOnset . The aim of this study is to assess the sensitivity of the quantification process to tOnset at voxel level. Perfusion data were obtained from series of simulated data, a hardware perfusion phantom, and patients. Fermi deconvolution has been used for analysis. A novel algorithm, based on sequential deconvolution,which minimizes the error between myocardial curves and fitted curves obtained after deconvolution, has been used to identify the optimal tOnset for each region. Voxel-wise analysis showed to be more sensitive to tOnset compared to segmental analysis. The automated detection of the tOnset allowed a net improvement of the accuracy of MBF quantification and in patients the identification of perfusion abnormalities in territories that were missed when a constant user-selected tOnset was used. Our results indicate that high-resolution MBF quantification should be performed with optimized tOnset values at voxel level.


Asunto(s)
Técnicas de Imagen Cardíaca/métodos , Medios de Contraste/farmacocinética , Circulación Coronaria/fisiología , Angiografía por Resonancia Magnética/métodos , Imagen de Perfusión/métodos , Estudios de Casos y Controles , Simulación por Computador , Enfermedad de la Arteria Coronaria/fisiopatología , Humanos , Fantasmas de Imagen
3.
J Magn Reson Imaging ; 39(4): 895-900, 2014 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-24123369

RESUMEN

PURPOSE: To determine sex-specific reference values for left ventricular (LV) volumes, mass, and ejection fraction (EF) in healthy adults using computer-aided analysis and to examine the effect of age on LV parameters. MATERIALS AND METHODS: We examined data from 1494 members of the Framingham Heart Study Offspring cohort, obtained using short-axis stack cine SSFP CMR, identified a healthy reference group (without cardiovascular disease, hypertension, or LV wall motion abnormality) and determined sex-specific upper 95th percentile thresholds for LV volumes and mass, and lower 5th percentile thresholds for EF using computer-assisted border detection. In secondary analyses, we stratified participants by age-decade and tested for linear trend across age groups. RESULTS: The reference group comprised 685 adults (423F; 61 ± 9 years). Men had greater LV volumes and mass, before and after indexation to common measures of body size (all P = 0.001). Women had greater EF (73 ± 6 versus 71 ± 6%; P = 0.0002). LV volumes decreased with greater age in both sexes, even after indexation. Indexed LV mass did not vary with age. LV EF and concentricity increased with greater age in both sexes. CONCLUSION: We present CMR-derived LV reference values. There are significant age and sex differences in LV volumes, EF, and geometry, whereas mass differs between sexes but not age groups.


Asunto(s)
Envejecimiento/fisiología , Ventrículos Cardíacos/anatomía & histología , Interpretación de Imagen Asistida por Computador/métodos , Imagenología Tridimensional/métodos , Imagen por Resonancia Cinemagnética/métodos , Volumen Sistólico/fisiología , Función Ventricular Izquierda/fisiología , Adulto , Anciano , Anciano de 80 o más Años , Algoritmos , Femenino , Humanos , Aumento de la Imagen/métodos , Masculino , Persona de Mediana Edad , Tamaño de los Órganos/fisiología , Reconocimiento de Normas Patrones Automatizadas/métodos , Valores de Referencia , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
4.
Med Biol Eng Comput ; 51(11): 1271-86, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-23892889

RESUMEN

Coronary artery disease, CAD, is associated with both narrowing of the epicardial coronary arteries and microvascular disease, thereby limiting coronary flow and myocardial perfusion. CAD accounts for almost 2 million deaths within the European Union on an annual basis. In this paper, we review the physiological and pathophysiological processes underlying clinical decision making in coronary disease as well as the models for interpretation of the underlying physiological mechanisms. Presently, clinical decision making is based on non-invasive magnetic resonance imaging, MRI, of myocardial perfusion and invasive coronary hemodynamic measurements of coronary pressure and Doppler flow velocity signals obtained during catheterization. Within the euHeart project, several innovations have been developed and applied to improve diagnosis-based understanding of the underlying biophysical processes. Specifically, MRI perfusion data interpretation has been advanced by the gradientogram, a novel graphical representation of the spatiotemporal myocardial perfusion gradient. For hemodynamic data, functional indices of coronary stenosis severity that do not depend on maximal vasodilation are proposed and the Valsalva maneuver for indicating the extravascular resistance component of the coronary circulation has been introduced. Complementary to these advances, model innovation has been directed to the porous elastic model coupled to a one-dimensional model of the epicardial arteries. The importance of model development is related to the integration of information from different modalities, which in isolation often result in conflicting treatment recommendations.


Asunto(s)
Enfermedad de la Arteria Coronaria/diagnóstico , Técnicas de Diagnóstico Cardiovascular , Modelos Cardiovasculares , Presión Arterial , Enfermedad de la Arteria Coronaria/fisiopatología , Enfermedad de la Arteria Coronaria/terapia , Bases de Datos Factuales , Ecocardiografía Doppler , Humanos , Imagen por Resonancia Magnética , Imagen de Perfusión Miocárdica , Intervención Coronaria Percutánea
5.
JACC Cardiovasc Imaging ; 6(5): 600-9, 2013 May.
Artículo en Inglés | MEDLINE | ID: mdl-23582358

RESUMEN

OBJECTIVES: This study sought to test the hypothesis that transmural perfusion gradients (TPG) on adenosine stress myocardial perfusion cardiac magnetic resonance (CMR) predict hemodynamically significant coronary artery disease (CAD) as defined by fractional flow reserve (FFR). BACKGROUND: Myocardial ischemia affects the subendocardial layers of the left ventricular myocardium earlier and more severely than the outer layers, and the identification of TPG should be sensitive and specific for the diagnosis of CAD. Previous studies have shown that high spatial resolution myocardial perfusion CMR allows quantitation of TPG between the subendocardium and the subepicardium. METHODS: Sixty-seven patients (53 men, age 61 ± 9 years) underwent coronary angiography and high-resolution (1.2 × 1.2-mm in-plane) adenosine stress perfusion CMR at 3.0-T. TPG was calculated for 3 coronary territories. Visual analysis was performed to identify myocardial ischemia. FFR was measured in all vessels with ≥50% severity stenosis. FFR <0.8 was considered hemodynamically significant. In a training group of 30 patients, the optimal threshold of TPG to detect significant CAD was determined (Group 1). This threshold was then tested prospectively in the remaining 37 patients (Group 2). RESULTS: In Group 1, a 20% TPG provided the best diagnostic threshold on both per-segment and per-patient analysis. Applied to Group 2, this threshold yielded a sensitivity of 0.78, specificity of 0.94, and area under the curve of 0.86 for the detection of CAD in a per-segment analysis and of 0.89, 0.83, and 0.86 in a per-patient analysis, respectively. TPG had a similar diagnostic accuracy to visual assessment. Linear regression analysis showed a relationship between TPG and FFR values, with r = 0.63 (p < 0.001). CONCLUSIONS: The quantitative analysis of transmural perfusion gradients on high-resolution myocardial perfusion CMR accurately predicts hemodynamically significant CAD as defined by FFR. A TPG diagnostic threshold of 20% is as accurate as visual assessment.


Asunto(s)
Estenosis Coronaria/diagnóstico , Vasos Coronarios/fisiopatología , Reserva del Flujo Fraccional Miocárdico , Imagen por Resonancia Magnética , Imagen de Perfusión Miocárdica/métodos , Adenosina , Anciano , Distribución de Chi-Cuadrado , Angiografía Coronaria , Estenosis Coronaria/diagnóstico por imagen , Estenosis Coronaria/fisiopatología , Vasos Coronarios/diagnóstico por imagen , Femenino , Hemodinámica , Humanos , Modelos Lineales , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Curva ROC , Estudios Retrospectivos , Índice de Severidad de la Enfermedad , Vasodilatadores
6.
JACC Cardiovasc Imaging ; 5(11): 1115-23, 2012 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-23153911

RESUMEN

OBJECTIVES: The goal of this study was to assess the relationship of left ventricular (LV) trabeculae and papillary muscles (TPM) with clinical characteristics in a community-based, free-living adult cohort and to determine the effect of TPM on quantitative measures of LV volume, mass, and ejection fraction (EF). BACKGROUND: Hypertrabeculation has been associated with adverse cardiovascular events, but the distribution and clinical correlates of the volume and mass of the TPM in a normal left ventricle have not been well characterized. METHODS: Short-axis cine cardiac magnetic resonance images, obtained using a steady-state free precession sequence from 1,494 members of the Framingham Heart Study Offspring cohort, were analyzed with software that automatically segments TPM. Absolute TPM volume, TPM as a fraction of end-diastolic volume (EDV) (TPM/EDV), and TPM mass as a fraction of LV mass were determined in all offspring and in a referent group of offspring free of clinical cardiovascular disease and hypertension. RESULTS: In the referent group (mean age 61 ± 9 years; 262 men and 423 women), mean TPM was 23 ± 3% of LV EDV in both sexes (p = 0.9). TPM/EDV decreased with age (p < 0.02) but was not associated with body mass index. TPM mass as a fraction of LV mass was inversely correlated with age (p < 0.0001), body mass index (p < 0.018), and systolic blood pressure (p < 0.0001). Among all 1,494 participants (699 men), LV volumes decreased 23%, LV mass increased 28%, and EF increased by 7.5 EF units (p < 0.0001) when TPM were considered myocardial mass rather than part of the LV blood pool. CONCLUSIONS: Global cardiac magnetic resonance LV parameters were significantly affected by whether TPM was considered as part of the LV blood pool or as part of LV mass. Our cross-sectional data from a healthy referent group of adults free of clinical cardiovascular disease demonstrated that TPM/EDV decreases with increasing age in both sexes but is not related to hypertension or obesity.


Asunto(s)
Ventrículos Cardíacos/anatomía & histología , Imagen por Resonancia Cinemagnética , Músculos Papilares/anatomía & histología , Músculos Papilares/fisiología , Función Ventricular Izquierda , Factores de Edad , Anciano , Presión Sanguínea , Índice de Masa Corporal , Estudios Transversales , Femenino , Humanos , Hipertensión/patología , Hipertensión/fisiopatología , Interpretación de Imagen Asistida por Computador , Modelos Lineales , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Valores de Referencia , Reproducibilidad de los Resultados , Factores Sexuales , Volumen Sistólico , Disfunción Ventricular Izquierda/patología , Disfunción Ventricular Izquierda/fisiopatología
7.
Magn Reson Med ; 68(6): 1994-2004, 2012 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-22354744

RESUMEN

The purpose of this study is to enable high spatial resolution voxel-wise quantitative analysis of myocardial perfusion in dynamic contrast-enhanced cardiovascular MR, in particular by finding the most favorable quantification algorithm in this context. Four deconvolution algorithms--Fermi function modeling, deconvolution using B-spline basis, deconvolution using exponential basis, and autoregressive moving average modeling--were tested to calculate voxel-wise perfusion estimates. The algorithms were developed on synthetic data and validated against a true gold-standard using a hardware perfusion phantom. The accuracy of each method was assessed for different levels of spatial averaging and perfusion rate. Finally, voxel-wise analysis was used to generate high resolution perfusion maps on real data acquired from five patients with suspected coronary artery disease and two healthy volunteers. On both synthetic and perfusion phantom data, the B-spline method had the highest error in estimation of myocardial blood flow. The autoregressive moving average modeling and exponential methods gave accurate estimates of myocardial blood flow. The Fermi model was the most robust method to noise. Both simulations and maps in the patients and hardware phantom showed that voxel-wise quantification of myocardium perfusion is feasible and can be used to detect abnormal regions.


Asunto(s)
Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/fisiopatología , Circulación Coronaria , Interpretación de Imagen Asistida por Computador/métodos , Angiografía por Resonancia Magnética/métodos , Imagen por Resonancia Cinemagnética/métodos , Imagen de Perfusión Miocárdica/métodos , Velocidad del Flujo Sanguíneo , Estudios de Factibilidad , Humanos , Aumento de la Imagen/métodos , Imagenología Tridimensional/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
8.
Magn Reson Med ; 67(5): 1478-86, 2012 May.
Artículo en Inglés | MEDLINE | ID: mdl-22021128

RESUMEN

Quantitative analysis of short-axis functional cardiac magnetic resonance images can be performed using automatic contour detection methods. The resulting myocardial contours must be reviewed and possibly corrected, which can be time-consuming, particularly when performed across all cardiac phases. We quantified the impact of manual contour corrections on both analysis time and quantitative measurements obtained from left ventricular short-axis cine images acquired from 1555 participants of the Framingham Heart Study Offspring cohort using computer-aided contour detection methods. The total analysis time for a single case was 7.6 ± 1.7 min for an average of 221 ± 36 myocardial contours per participant. This included 4.8 ± 1.6 min for manual contour correction of 2% of all automatically detected endocardial contours and 8% of all automatically detected epicardial contours. However, the impact of these corrections on global left ventricular parameters was limited, introducing differences of 0.4 ± 4.1 mL for end-diastolic volume, -0.3 ± 2.9 mL for end-systolic volume, 0.7 ± 3.1 mL for stroke volume, and 0.3 ± 1.8% for ejection fraction. We conclude that left ventricular functional parameters can be obtained under 5 min from short-axis functional cardiac magnetic resonance images using automatic contour detection methods. Manual correction more than doubles analysis time, with minimal impact on left ventricular volumes and ejection fraction.


Asunto(s)
Algoritmos , Interpretación de Imagen Asistida por Computador/métodos , Imagenología Tridimensional/métodos , Imagen por Resonancia Cinemagnética/métodos , Reconocimiento de Normas Patrones Automatizadas/métodos , Disfunción Ventricular Izquierda/diagnóstico , Humanos , Aumento de la Imagen/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Volumen Sistólico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA