Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
1.
Eur Radiol ; 2023 Nov 24.
Artículo en Inglés | MEDLINE | ID: mdl-37999727

RESUMEN

OBJECTIVES: To investigate the influence of preoperative breast MRI on mastectomy and reoperation rates in patients with pure ductal carcinoma in situ (DCIS). METHODS: The MIPA observational study database (7245 patients) was searched for patients aged 18-80 years with pure unilateral DCIS diagnosed at core needle or vacuum-assisted biopsy (CNB/VAB) and planned for primary surgery. Patients who underwent preoperative MRI (MRI group) were matched (1:1) to those who did not receive MRI (noMRI group) according to 8 confounding covariates that drive referral to MRI (age; hormonal status; familial risk; posterior-to-nipple diameter; BI-RADS category; lesion diameter; lesion presentation; surgical planning at conventional imaging). Surgical outcomes were compared between the matched groups with nonparametric statistics after calculating odds ratios (ORs). RESULTS: Of 1005 women with pure unilateral DCIS at CNB/VAB (507 MRI group, 498 noMRI group), 309 remained in each group after matching. First-line mastectomy rate in the MRI group was 20.1% (62/309 patients, OR 2.03) compared to 11.0% in the noMRI group (34/309 patients, p = 0.003). The reoperation rate was 10.0% in the MRI group (31/309, OR for reoperation 0.40) and 22.0% in the noMRI group (68/309, p < 0.001), with a 2.53 OR of avoiding reoperation in the MRI group. The overall mastectomy rate was 23.3% in the MRI group (72/309, OR 1.40) and 17.8% in the noMRI group (55/309, p = 0.111). CONCLUSIONS: Compared to those going directly to surgery, patients with pure DCIS at CNB/VAB who underwent preoperative MRI had a higher OR for first-line mastectomy but a substantially lower OR for reoperation. CLINICAL RELEVANCE STATEMENT: When confounding factors behind MRI referral are accounted for in the comparison of patients with CNB/VAB-diagnosed pure unilateral DCIS, preoperative MRI yields a reduction of reoperations that is more than twice as high as the increase in overall mastectomies. KEY POINTS: • Confounding factors cause imbalance when investigating the influence of preoperative MRI on surgical outcomes of pure DCIS. • When patient matching is applied to women with pure unilateral DCIS, reoperation rates are significantly reduced in women who underwent preoperative MRI. • The reduction of reoperations brought about by preoperative MRI is more than double the increase in overall mastectomies.

2.
Eur Radiol ; 33(9): 6213-6225, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37138190

RESUMEN

OBJECTIVES: To report mastectomy and reoperation rates in women who had breast MRI for screening (S-MRI subgroup) or diagnostic (D-MRI subgroup) purposes, using multivariable analysis for investigating the role of MRI referral/nonreferral and other covariates in driving surgical outcomes. METHODS: The MIPA observational study enrolled women aged 18-80 years with newly diagnosed breast cancer destined to have surgery as the primary treatment, in 27 centres worldwide. Mastectomy and reoperation rates were compared using non-parametric tests and multivariable analysis. RESULTS: A total of 5828 patients entered analysis, 2763 (47.4%) did not undergo MRI (noMRI subgroup) and 3065 underwent MRI (52.6%); of the latter, 2441/3065 (79.7%) underwent MRI with preoperative intent (P-MRI subgroup), 510/3065 (16.6%) D-MRI, and 114/3065 S-MRI (3.7%). The reoperation rate was 10.5% for S-MRI, 8.2% for D-MRI, and 8.5% for P-MRI, while it was 11.7% for noMRI (p ≤ 0.023 for comparisons with D-MRI and P-MRI). The overall mastectomy rate (first-line mastectomy plus conversions from conserving surgery to mastectomy) was 39.5% for S-MRI, 36.2% for P-MRI, 24.1% for D-MRI, and 18.0% for noMRI. At multivariable analysis, using noMRI as reference, the odds ratios for overall mastectomy were 2.4 (p < 0.001) for S-MRI, 1.0 (p = 0.957) for D-MRI, and 1.9 (p < 0.001) for P-MRI. CONCLUSIONS: Patients from the D-MRI subgroup had the lowest overall mastectomy rate (24.1%) among MRI subgroups and the lowest reoperation rate (8.2%) together with P-MRI (8.5%). This analysis offers an insight into how the initial indication for MRI affects the subsequent surgical treatment of breast cancer. KEY POINTS: • Of 3065 breast MRI examinations, 79.7% were performed with preoperative intent (P-MRI), 16.6% were diagnostic (D-MRI), and 3.7% were screening (S-MRI) examinations. • The D-MRI subgroup had the lowest mastectomy rate (24.1%) among MRI subgroups and the lowest reoperation rate (8.2%) together with P-MRI (8.5%). • The S-MRI subgroup had the highest mastectomy rate (39.5%) which aligns with higher-than-average risk in this subgroup, with a reoperation rate (10.5%) not significantly different to that of all other subgroups.


Asunto(s)
Neoplasias de la Mama , Femenino , Humanos , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/cirugía , Mastectomía , Mastectomía Segmentaria , Mama , Imagen por Resonancia Magnética , Cuidados Preoperatorios
3.
Eur Radiol ; 32(3): 1611-1623, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34643778

RESUMEN

OBJECTIVES: Preoperative breast magnetic resonance imaging (MRI) can inform surgical planning but might cause overtreatment by increasing the mastectomy rate. The Multicenter International Prospective Analysis (MIPA) study investigated this controversial issue. METHODS: This observational study enrolled women aged 18-80 years with biopsy-proven breast cancer, who underwent MRI in addition to conventional imaging (mammography and/or breast ultrasonography) or conventional imaging alone before surgery as routine practice at 27 centers. Exclusion criteria included planned neoadjuvant therapy, pregnancy, personal history of any cancer, and distant metastases. RESULTS: Of 5896 analyzed patients, 2763 (46.9%) had conventional imaging only (noMRI group), and 3133 (53.1%) underwent MRI that was performed for diagnosis, screening, or unknown purposes in 692/3133 women (22.1%), with preoperative intent in 2441/3133 women (77.9%, MRI group). Patients in the MRI group were younger, had denser breasts, more cancers ≥ 20 mm, and a higher rate of invasive lobular histology than patients who underwent conventional imaging alone (p < 0.001 for all comparisons). Mastectomy was planned based on conventional imaging in 22.4% (MRI group) versus 14.4% (noMRI group) (p < 0.001). The additional planned mastectomy rate in the MRI group was 11.3%. The overall performed first- plus second-line mastectomy rate was 36.3% (MRI group) versus 18.0% (noMRI group) (p < 0.001). In women receiving conserving surgery, MRI group had a significantly lower reoperation rate (8.5% versus 11.7%, p < 0.001). CONCLUSIONS: Clinicians requested breast MRI for women with a higher a priori probability of receiving mastectomy. MRI was associated with 11.3% more mastectomies, and with 3.2% fewer reoperations in the breast conservation subgroup. KEY POINTS: • In 19% of patients of the MIPA study, breast MRI was performed for screening or diagnostic purposes. • The current patient selection to preoperative breast MRI implies an 11% increase in mastectomies, counterbalanced by a 3% reduction of the reoperation rate. • Data from the MIPA study can support discussion in tumor boards when preoperative MRI is under consideration and should be shared with patients to achieve informed decision-making.


Asunto(s)
Neoplasias de la Mama , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Mama , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/cirugía , Femenino , Humanos , Imagen por Resonancia Magnética , Mastectomía , Mastectomía Segmentaria , Persona de Mediana Edad , Cuidados Preoperatorios , Adulto Joven
4.
Eur Radiol ; 30(10): 5427-5436, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-32377813

RESUMEN

Despite its high diagnostic performance, the use of breast MRI in the preoperative setting is controversial. It has the potential for personalized surgical management in breast cancer patients, but two of three randomized controlled trials did not show results in favor of its introduction for assessing the disease extent before surgery. Meta-analyses showed a higher mastectomy rate in women undergoing preoperative MRI compared to those who do not. Nevertheless, preoperative breast MRI is increasingly used and a survey from the American Society of Breast Surgeons showed that 41% of respondents ask for it in daily practice. In this context, a large-scale observational multicenter international prospective analysis (MIPA study) was proposed under the guidance of the European Network for the Assessment of Imaging in Medicine (EuroAIM). The aims were (1) to prospectively and systematically collect data on consecutive women with a newly diagnosed breast cancer, not candidates for neoadjuvant therapy, who are offered or not offered breast MRI before surgery according to local practice; (2) to compare these two groups in terms of surgical and clinical endpoints, adjusting for covariates. The underlying hypotheses are that MRI does not cause additional mastectomies compared to conventional imaging, while reducing the reoperation rate in all or in subgroups of patients. Ninety-six centers applied to a web-based call; 36 were initially selected based on volume and quality standards; 27 were active for enrollment. On November 2018, the target of 7000 enrolled patients was reached. The MIPA study is presently at the analytic phase. Key Points • Breast MRI has a high diagnostic performance but its utility in the preoperative setting is controversial. • A large-scale observational multicenter prospective study was launched to compare women receiving with those not receiving preoperative MRI. • Twenty-seven centers enrolled more than 7000 patients. The study is presently at the analytic phase.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Protocolos de Ensayos Clínicos como Asunto , Imagen por Resonancia Magnética , Cuidados Preoperatorios , Anciano , Mama/diagnóstico por imagen , Neoplasias de la Mama/cirugía , Femenino , Humanos , Mastectomía , Persona de Mediana Edad , Estudios Prospectivos , Reoperación
5.
World J Surg ; 41(2): 464-471, 2017 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-27709273

RESUMEN

BACKGROUND: Techniques for accurately delineating the tumor bed after breast-conserving surgery (BCS) can be challenging. As a result, the accuracy, and efficiency of radiation treatment (RT) planning can be negatively impacted. Surgically placed clips or the post-surgical seroma are commonly used to determine target volume; however, these methods can lead to a high degree of uncertainty and variability. A novel 3-dimensional bioabsorbable marker was used during BCS and assessed for its impact on RT planning. METHODS: One hundred and ten implants were sutured to the margins of the tumor bed excision site in 108 patients undergoing BCS. Routine CT imaging of the breast tissue was performed for RT planning, and the marker was assessed for visibility and utility in target delineation. RT regimens, target volumes and associated treatment costs were analyzed. RESULTS: In all patients, the marker was easily visible and in 95.7 % of cases, it proved useful for RT planning. 36.8 % of patients received conventional whole breast irradiation plus boost, 56.6 % received hypo-fractionation plus boost, and 6.6 % received accelerated partial breast irradiation. A shift toward increased use of hypo-fractionated regimens was noted over the three year period of this study. There were no device-related complications or cancer recurrences in this group of patients. CONCLUSIONS: This study demonstrated the use of a novel 3-dimensional marker as a safe and effective method for delineating the tumor bed with a significant utility for RT planning. With routine use of the device, an increased use of hypofractionation with a resultant 25 % cost savings was noted.


Asunto(s)
Implantes Absorbibles , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/radioterapia , Marcadores Fiduciales , Planificación de la Radioterapia Asistida por Computador , Anciano , Anciano de 80 o más Años , Neoplasias de la Mama/cirugía , Fraccionamiento de la Dosis de Radiación , Femenino , Humanos , Mastectomía Segmentaria , Persona de Mediana Edad , Radioterapia Adyuvante , Tomografía Computarizada por Rayos X
7.
Radiology ; 265(1): 51-8, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-22923716

RESUMEN

PURPOSE: To assess diagnostic performance of dedicated breast magnetic resonance (MR) imaging at breast imaging centers by using a dedicated 1.5-T breast MR system that used high-spatial-resolution, high-contrast-resolution spiral trajectory acquisitions. MATERIALS AND METHODS: The study was institutional review board approved and HIPAA compliant, with waiver of informed consent. Diagnostic performance was retrospectively assessed for 934 consecutive screening (n=347) and diagnostic (n=587) examinations performed from April 2006 to December 2007 in women aged 25-89 years old from four sites for which dedicated breast MR imaging reports and ground truth (biopsy for cancer cases, 1-year follow-up with negative results for cases with negative findings) were available. The sensitivity, specificity, and receiver operating characteristic (ROC) for breast MR imaging were determined. RESULTS: The sensitivity and specificity for the dedicated breast MR imaging system were 92% (92 of 100) and 88.8% (741 of 834). For all cases, the negative predictive value (NPV) was 98.9% (741 of 749). The NPV for screening cases was 100% (326 of 326). The area under the ROC curve was 0.942. Of the 93 cases with false-positive findings seen at dedicated breast MR imaging, 25 (27%) were high-risk histologic findings for which excision is often recommended. The false-positive rate was 93 of 834 (11.2%) for all cases, but only 16 of 326 (4.9%) for the screening cohort. CONCLUSION: High accuracy was achieved by using dedicated breast MR imaging.


Asunto(s)
Neoplasias de la Mama/diagnóstico , Imagen por Resonancia Magnética/instrumentación , Adulto , Anciano , Anciano de 80 o más Años , Biopsia , Neoplasias de la Mama/patología , Medios de Contraste , Diagnóstico Diferencial , Femenino , Humanos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Curva ROC , Estudios Retrospectivos , Sensibilidad y Especificidad
8.
Eur J Radiol ; 81(4): e618-24, 2012 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-22266417

RESUMEN

PURPOSE: Breast density has been found to be a potential indicator for breast cancer risk. The estimation of breast density can be seen as a segmentation problem on fibroglandular tissues from a breast magnetic resonance image. The classic moment preserving is a thresholding method, which can be applied to determine an appropriate threshold value for fibroglandular tissue segmentation. METHODS: This study proposed an adaptive moment preserving method, which combines the classic moment preserving and a thresholding adjustment method. The breast MR images are firstly performed to extract the fibroglandular tissue from the breast tissue. The next step is to obtain the areas of the fibroglandular tissue and the whole breast tissue. Finally, breast density can be estimated for the given breast. RESULTS: The Friedman test shows that the qualities of segmentation are insignificant with p<0.000 and Friedman chi-squared=1116.12. The Friedman test shows that there would be significant differences in the sum of the ranks of at least one segmentation method. Average ranks indicate that the performance of the four methods is ranked as adaptive moment preserving, fuzzy c-means, moment preserving, and Kapur's method in order. Among the four methods, adaptive moment preserving also achieves the minimum values of MAE and RMSE with 9.2 and 12. CONCLUSION: This study has verified that the proposed adaptive moment preserving can identify and segment the fibroglandular tissues from the 2D breast MR images and estimate the degrees of breast density.


Asunto(s)
Mama/patología , Mama/fisiopatología , Densitometría/métodos , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos , Reconocimiento de Normas Patrones Automatizadas/métodos , Técnica de Sustracción , Adulto , Algoritmos , Femenino , Humanos , Aumento de la Imagen/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
9.
J Am Coll Surg ; 209(4): 504-20, 2009 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-19801324
10.
Am Surg ; 74(8): 739-42, 2008 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-18705577

RESUMEN

Pathologic nipple discharge often presents a diagnostic and therapeutic dilemma for clinicians. We present two patients with pathologic nipple discharge in whom breast MR facilitated preoperative identification of and management of otherwise occult index lesions. Breast MR should be considered in the toolbox for evaluation of occult nipple discharge when other available strategies have failed to demonstrate an underlying etiology for the pathologic discharge. The use of breast MR in this setting may permit directed evaluation and management of potentially malignant lesions.


Asunto(s)
Neoplasias de la Mama/diagnóstico , Carcinoma in Situ/diagnóstico , Carcinoma Ductal/diagnóstico , Imagen por Resonancia Magnética/métodos , Pezones/metabolismo , Anciano , Diagnóstico Diferencial , Exudados y Transudados , Femenino , Humanos , Persona de Mediana Edad
11.
CA Cancer J Clin ; 57(2): 75-89, 2007.
Artículo en Inglés | MEDLINE | ID: mdl-17392385

RESUMEN

New evidence on breast Magnetic Resonance Imaging (MRI) screening has become available since the American Cancer Society (ACS) last issued guidelines for the early detection of breast cancer in 2003. A guideline panel has reviewed this evidence and developed new recommendations for women at different defined levels of risk. Screening MRI is recommended for women with an approximately 20-25% or greater lifetime risk of breast cancer, including women with a strong family history of breast or ovarian cancer and women who were treated for Hodgkin disease. There are several risk subgroups for which the available data are insufficient to recommend for or against screening, including women with a personal history of breast cancer, carcinoma in situ, atypical hyperplasia, and extremely dense breasts on mammography. Diagnostic uses of MRI were not considered to be within the scope of this review.


Asunto(s)
Neoplasias de la Mama/diagnóstico , Imagen por Resonancia Magnética , Mamografía , Neoplasias de la Mama/genética , Femenino , Predisposición Genética a la Enfermedad , Pruebas Genéticas , Humanos , Imagen por Resonancia Magnética/efectos adversos , Factores de Riesgo , Sensibilidad y Especificidad
12.
Radiology ; 238(1): 42-53, 2006 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-16373758

RESUMEN

PURPOSE: To prospectively determine the prevalence and predictive value of three-dimensional (3D) and dynamic breast magnetic resonance (MR) imaging and contrast material kinetic features alone and as part of predictive diagnostic models. MATERIALS AND METHODS: The study protocol was approved by the institutional review board or ethics committees of all participating institutions, and informed consent was obtained from all participants. Although study data collection was performed before HIPAA went into effect, standards that would be compliant with HIPAA were adhered to. Data from the International Breast MR Consortium trial 6883 were used in the analysis. Women underwent 3D (minimum spatial resolution, 0.7 x 1.4 x 3 mm; minimal temporal resolution, 4 minutes) and dynamic two-dimensional (temporal resolution, 15 seconds) MR imaging examinations. Readers rated enhancement shape, enhancement distribution, border architecture, enhancement intensity, presence of rim enhancement or internal septations, and the shape of the contrast material kinetic curve. Regression was performed for each feature individually and after adjustment for associated mammographic findings. Multivariate models were also constructed from multiple architectural and dynamic features. Areas under the receiver operating characteristic curve (Az values) were estimated for all models. RESULTS: There were 995 lesions in 854 women (mean age, 53 years +/- 12 [standard deviation]; range, 18-80 years) for whom pathology data were available. The absence of enhancement was associated with an 88% negative predictive value for cancer. Qualitative characterization of the dynamic enhancement pattern was associated with an Az value of 0.66 across all lesion architectures. Focal mass margins (Az = 0.76) and signal intensity (Az = 0.70) were highly predictive imaging features. Multivariate models were constructed with an Az value of 0.880. CONCLUSION: Architectural and dynamic features are important in breast MR imaging interpretation. Multivariate models involving feature assessment have a diagnostic accuracy superior to that of qualitative characterization of the dynamic enhancement pattern.


Asunto(s)
Neoplasias de la Mama/diagnóstico , Imagen por Resonancia Magnética/métodos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Algoritmos , Teorema de Bayes , Neoplasias de la Mama/patología , Medios de Contraste/farmacocinética , Diagnóstico Diferencial , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Imagenología Tridimensional , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Curva ROC , Análisis de Regresión , Sensibilidad y Especificidad
14.
Am J Surg ; 190(4): 623-7, 2005 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-16164936

RESUMEN

BACKGROUND: Determining the extent of infiltrating lobular carcinoma (ILCA) in the breast is difficult. This study was designed to determine if the size of ILCA on magnetic resonance imaging (MRI) correlated with final pathology. METHODS: Retrospective study of patients between 1998 and 2004, who were evaluated for extent of ILCA prior to definitive treatment, was conducted. Demographic data and radiology and pathology results were obtained. Spearman correlation coefficient was used. RESULTS: Twenty-nine patients (median age 62 years) had MRI of breast. Fourteen patients (48%) had contralateral MRIs; 13 (45%) normal; 1 (8%) prompted core biopsy; 6 of 13 patients underwent contralateral mastectomies, which were benign. The distribution of tumor size was: T1 = 15 (52%); T2 = 7 (24%); T3 = 5 (17%); T4 = 2 (7%). Spearman correlation coefficient between tumor size on ultrasound and MRI with pathology was .19 (P = .5) and .88 (P < .001), respectively. CONCLUSION: MRI provided superior correlation between tumor size and pathology.


Asunto(s)
Neoplasias de la Mama/diagnóstico , Carcinoma Lobular/diagnóstico , Imagen por Resonancia Magnética/métodos , Anciano , Pesos y Medidas Corporales , Neoplasias de la Mama/patología , Carcinoma Lobular/patología , Medios de Contraste , Femenino , Gadolinio , Humanos , Imagenología Tridimensional , Persona de Mediana Edad , Estudios Retrospectivos
16.
J Surg Oncol ; 92(1): 32-8, 2005 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-16180227

RESUMEN

BACKGROUND: Prior single institution studies suggest MRI may improve the assessment of the extent of cancer within the breast, and thus reduce the risk of leaving macroscopic disease in the breast following breast conservation therapy. We report on the rate of MRI and mammography detection of foci of distinct incidental cancer in a prospective, multi center trial involving 426 women with confirmed breast cancer at 15 institutions in the US, Canada, and Germany. METHODS: Women underwent mammography and MRI prior to biopsy of the suspicious index lesion. Additional incidental lesions (IL) greater than 2 cm from the index lesion that were detected by mammography and MRI were noted and characterized. Biopsy recommendations were associated with ILs given an assessment of suspicious or highly suspicous (BiRads 4 and 5). These assessments were considered a positive test. RESULTS: MRI had a significantly higher yield of confirmed cancer ILs than mammography (0.18 (95%CI: 0.142-0.214) for MRI versus 0.072 (95%CI: 0.050-0.100) for mammography). The cancer ILs detected by MRI alone appeared to be similar to those detected by mammography with respect to size and histology. The percentage of biopsies of ILs that resulted in a cancer diagnosis was similar between the modalities (MRI 0.72(95%CI: 0.6-0.81); Mammography 0.85 (95%CI: 0.62-0.96)). CONCLUSIONS: These results suggest that consideration needs to be given regarding the integration of breast MRI into the pretreatment evaluation of women seeking breast conservation therapy.


Asunto(s)
Neoplasias de la Mama/diagnóstico , Imagen por Resonancia Magnética , Mamografía , Biopsia , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/patología , Estudios de Cohortes , Femenino , Humanos , Persona de Mediana Edad , Sensibilidad y Especificidad
17.
Cancer ; 103(9): 1898-905, 2005 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-15800894

RESUMEN

BACKGROUND: The authors compared the performance of screening mammography versus magnetic resonance imaging (MRI) in women at genetically high risk for breast cancer. METHODS: The authors conducted an international prospective study of screening mammography and MRI in asymptomatic, genetically high-risk women age >/= 25 years. Women with a history of breast cancer were eligible for a contralateral screening if they had been diagnosed within 5 years or a bilateral screening if they had been diagnosed > 5 years previously. All examinations (MRI, mammography, and clinical breast examination [CBE]) were performed within 90 days of each other. RESULTS: In total, 390 eligible women were enrolled by 13 sites, and 367 women completed all study examinations. Imaging evaluations recommended 38 biopsies, and 27 biopsies were performed, resulting in 4 cancers diagnosed for an overall 1.1% cancer yield (95% confidence interval [95%CI], 0.3-2.8%). MRI detected all four cancers, whereas mammography detected one cancer. The diagnostic yield of mammography was 0.3% (95%CI, 0.01-1.5%). The yield of cancer by MRI alone was 0.8% (95%CI, - 0.3-2.0%). The biopsy recommendation rates for MRI and mammography were 8.5% (95%CI, 5.8-11.8%) and 2.2% (95%CI, 0.1-4.3%). CONCLUSIONS: Screening MRI in high-risk women was capable of detecting mammographically and clinically occult breast cancer. Screening MRI resulted in 22 of 367 of women (6%) who had negative mammogram and negative CBE examinations undergoing biopsy, resulting in 3 additional cancers detected. MRI also resulted in 19 (5%) false-positive outcomes, which resulted in benign biopsies.


Asunto(s)
Neoplasias de la Mama/diagnóstico , Imagen por Resonancia Magnética , Mamografía , Adulto , Anciano , Biopsia , Carcinoma in Situ/diagnóstico , Carcinoma Ductal de Mama/diagnóstico , Carcinoma Lobular/diagnóstico , Femenino , Humanos , Hiperplasia/diagnóstico , Tamizaje Masivo , Persona de Mediana Edad , Factores de Riesgo , Sensibilidad y Especificidad
18.
JAMA ; 292(22): 2735-42, 2004 Dec 08.
Artículo en Inglés | MEDLINE | ID: mdl-15585733

RESUMEN

CONTEXT: Breast magnetic resonance imaging (MRI) has been shown to have high sensitivity for cancer detection and is increasingly used following mammography to evaluate suspicious breast lesions. OBJECTIVE: To determine the accuracy of breast MRI in conjunction with mammography for the detection of breast cancer in patients with suspicious mammographic or clinical findings. DESIGN, SETTING, AND PATIENTS: Prospective multicenter investigation of the International Breast MR Consortium conducted at 14 university hospitals in North America and Europe from June 2, 1998, through October 31, 2001, of 821 patients referred for breast biopsy for American College of Radiology category 4 or 5 mammographic assessment or suspicious clinical or ultrasound finding. INTERVENTIONS: MRI examinations performed prior to breast biopsy; MRI results were interpreted at each site, which were blinded to pathological results. MAIN OUTCOME MEASURES: Area under the receiver operating characteristic curve (AUC), sensitivity, and specificity of breast MRI. RESULTS: Among the 821 patients, there were 404 malignant index lesions, of which 63 were ductal carcinoma in situ (DCIS) and 341 were invasive carcinoma. Of the 417 nonmalignant index lesions, 366 were benign, 47 showed atypical histology, and 4 were lobular carcinoma in situ. The AUC pooled over all institutions was 0.88 (95% confidence interval [CI], 0.86-0.91). MRI correctly detected cancer in 356 of 404 cancer cases (DCIS or invasive cancer), resulting in a sensitivity of 88.1% (95% CI, 84.6%-91.1%), and correctly identified as negative for cancer 281 of 417 cases without cancer, resulting in a specificity of 67.7% (95% CI, 62.7%-71.9%). MRI performance was not significantly affected by mammographic breast density, tumor histology, or menopausal status. The positive predictive values for 356 of 492 patients was 72.4% (95% CI, 68.2%-76.3%) and of mammography for 367 of 695 patients was 52.8% (95% CI, 49.0%-56.6%) (P<.005). Dynamic MRI did not improve the AUC compared with 3-dimensional MRI alone, but the specificity of a washout pattern for 123 of 136 patients without cancer was 90.4% (95% CI, 84%-95%). CONCLUSIONS: Breast MRI has high sensitivity but only moderate specificity independent of breast density, tumor type, and menopausal status. Although the positive predictive value of MRI is greater than mammography, MRI does not obviate the need for subsequent tissue sampling in this setting.


Asunto(s)
Neoplasias de la Mama/diagnóstico , Imagen por Resonancia Magnética , Adulto , Biopsia , Femenino , Humanos , Mamografía , Persona de Mediana Edad , Estudios Prospectivos , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA