1.
Radiat Prot Dosimetry ; 121(4): 382-90, 2006.
Artículo en Inglés | MEDLINE | ID: mdl-16785243

RESUMEN

In this research, total effective dose equivalent (TEDE) and collective dose (CD) are calculated for the most adverse potential accident in Bushehr Nuclear Power Plant from the viewpoint of radionuclides release to the environment. Calculations are performed using a Gaussian diffusion model and a slightly modified version of AIREM computer code to adopt for conditions in Bushehr. The results are comparable with the final safety analysis report which used DOZAM code. Results of our calculations show no excessive dose in populated regions. Maximum TEDE is determined to be in the WSW direction. CD in the area around the nuclear power plant by a distance of 30 km (138 man Sv) is far below the accepted limits. Thyroid equivalent dose is also calculated for the WSW direction (maximum 25.6 mSv) and is below the limits at various distances from the reactor stack.


Asunto(s)
Contaminantes Radiactivos del Aire/análisis , Exposición a Riesgos Ambientales/análisis , Modelos Biológicos , Monitoreo de Radiación/métodos , Protección Radiológica/métodos , Liberación de Radiactividad Peligrosa , Medición de Riesgo/métodos , Carga Corporal (Radioterapia) , Simulación por Computador , Humanos , Irán , Dosis de Radiación , Efectividad Biológica Relativa , Factores de Riesgo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA