Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
BMC Oral Health ; 23(1): 367, 2023 06 07.
Artículo en Inglés | MEDLINE | ID: mdl-37287027

RESUMEN

BACKGROUND: Resin composite restorations are highly esthetic restorations, which should have and maintain high surface polish. However, esthetic restorations are subjected to different beverages at variable temperatures, which may affect their surface roughness. This study aimed to evaluate the surface roughness of single-shade (Omnichroma) and multi-shade (Filtek Z350XT) composite materials, following aging by immersion and thermocycling in different beverages, simulating one year of clinical service. METHODS: Thirty specimens of each material were prepared and divided into 6 subgroups (n = 5). In each material, the grouping of the specimens was as follows: the first subgroup was the as-prepared specimens stored dry without immersion or thermocycling. The second, third, and fourth subgroups were immersed in saliva, tea, and red wine, respectively, for 12 days at 37 °C. The fifth and sixth subgroups were thermocycled for 10,000 cycles, in tea (the fifth between 37 and 57 °C) and in red wine (the sixth between 37 °C and12°C). The resultant surface roughness was measured by two different methods, stylus profilometer and atomic force microscopy (AFM). Intergroup comparison was performed using independent t test, while intragroup comparison was performed using one-way analysis of variance (ANOVA) followed by Tukey's post-hoc test. RESULTS: Intergroup comparison between both composites showed no statistically significant differences in all groups using the stylus profilometer roughness measurements (P>0.05), while the AFM measurements showed significant difference (P ≤ 0.05) within all storage media except the as-prepared control (P = 0.0645), where nanofilled Filtek Z350 XT showed lower nano-roughness. Intragroup comparison data were variable, depending on the material, aging conditions, and roughness assessment tool. However, the resultant average surface roughness (Ra) values in all groups did not exceed the threshold value of Ra 0.2 µm. CONCLUSIONS: Both resin composites attained and retained a clinically acceptable surface finish after immersion and thermocycling in different beverages.


Asunto(s)
Resinas Compuestas , Inmersión , Humanos , Bebidas , , Propiedades de Superficie , Ensayo de Materiales , Color
2.
J Funct Biomater ; 15(1)2023 Dec 28.
Artículo en Inglés | MEDLINE | ID: mdl-38248679

RESUMEN

Ceramic thickness and technicians' manipulative variables are critical factors affecting the resultant shade of dental ceramo-metallic restorations. This study investigated the effect of the following variables on shade duplication of ceramo-metallic specimens: (a) ceramic thickness; (b) differences between several technicians (inter-technician variability); and (c) the ability of each technician to repeat the resultant shade (intra-technician variability). Ninety ceramo-metallic specimens were prepared and divided into three main groups (n = 30/gp) according to the different technicians who built up the veneering ceramic of the specimens. Each group was further subdivided into three subgroups (n = 10/subgroup) according to the thickness of the ceramic (1, 1.5, and 2 mm built over a 0.5 mm-thick metal substructure). Three different technicians were asked to follow the same protocol as regards the same ceramic batch (Shade 3M2, Vita VM13, Zahnfabrik, Germany), firing temperature, and number of firing cycles. Meanwhile, each technician followed his own protocol with regard to other ceramic manipulative variables. The duplicated shades of the specimens were investigated using the Vita Easyshade spectrophotometer by using the verify shade mode. Color difference (∆E) values were calculated between the target shade (3M2) and the duplicated shades of the specimens automatically by the Vita Easyshade spectrophotometer (Vita, Zahnfabrik, Germany). The effect of ceramic thickness and inter- and intra-technician variability on the duplication of the target shade was investigated. The results showed that the effect of ceramic thickness on the duplicated shades depended on inter-technician variability. High inter-technician variability (∆E = 2-6.4) was noticed in contrast to low intra-technician variability (∆E = 0.2-1.5). It could be concluded that proper shade-duplication of ceramo-metallic restoration was a cumulative technique intimately related to manipulative variables and ceramic thickness.

3.
BMC Oral Health ; 22(1): 321, 2022 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-35915423

RESUMEN

The long-term color stability and gloss retention of resin composites are among the crucial factors that affect the clinical longevity of esthetic restorations, especially in anterior teeth. This study evaluated the effect of artificial aging by immersion in different storage media and thermocycling on color and gloss of dental single-shade resin composite (Omnichroma) versus multi-shade one (Filtek Z350XT). One hundred resin-composite disc-shaped specimens were used, 50 from each group, Omnichroma and Filtek Z350XT. Ten specimens from each material acted as control group (incubated in saliva). For each material, 40 specimens were divided according to the artificial-aging protocol (immersion at 37 °C for 12 days or thermocycling for 10,000 cycles) and storage media (tea, red wine). Color and gloss were measured before and after artificial aging. Color difference (∆E00) was compared with perceptibility threshold and acceptability threshold. Data were statistically analyzed; independent t test was used to compare results between two tested materials, while two-way ANOVA was used to compare results among the different immersion media within the same material. Artificial aging (immersion or thermocycling) in tea and red wine led to significant color changes and gloss reduction in both materials (P < 0.05), in contrast to control group. Red wine produced highest color differences. Both dental resin-composites; the single-shade (Omnichroma) and multi-shade (Filtek Z350XT) displayed unacceptable discoloration and gloss reduction after artificial-aging in tea and red-wine by immersion or thermocycling simulating one-year clinical-service.


Asunto(s)
Resinas Compuestas , , Color , Humanos , Ensayo de Materiales , Propiedades de Superficie
4.
J Esthet Restor Dent ; 33(4): 636-647, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33665948

RESUMEN

OBJECTIVES: To study the effect of artificial aging on color stability, translucency, and surface roughness of stained all-ceramic restorations. MATERIALS AND METHODS: Disc-shaped specimens were fabricated from six different all-ceramic materials: two glass ceramics (Vita Mark II and Empress CAD), two lithium disilicate based ceramics (e.max and Suprinity), and two zirconia-based materials (ZirCAD LT and ZirCAD MT Multi). The discs were stained using two universal stains; IPS Ivocolor stain or Vita Akzent stain. Color change (ΔE) and the translucency parameter (TP) were measured before and after artificial aging. The surface roughness (Ra) was evaluated using atomic force microscopy, while the surface microstructure was evaluated using scanning electron microscopy (SEM). Quantitative elemental analysis was performed using the energy dispersive X-ray (EDX). Leached ions were analyzed by inductively coupled plasma (ICP) (n = 12, α = 0.05). RESULTS: Artificial aging had significantly changed the color (ΔE) and decreased the translucency (TP) of all stained ceramics. The mean surface roughness (Ra) was significantly increased in all specimens, which was also confirmed in the SEM scans. EDX analysis revealed a decrease in the elemental composition of the stained surface as a result of ceramic degradation, except for Ca and Zn in IPS Ivocolor stain. Furthermore, the ICP analysis revealed that most compositional elements of stain and glaze were detected in the aging solution. CONCLUSIONS: Chemical aging had significantly affected the optical parameters and surface texture of stained monolithic ceramics. CLINICAL SIGNIFICANCE: Stained ceramics are liable to color degradation. Each type of stain should be used with its corresponding type of ceramic. Stained all-ceramic restorations are liable to color change and surface degradation during function.


Asunto(s)
Cerámica , Porcelana Dental , Color , Diseño Asistido por Computadora , Ensayo de Materiales , Propiedades de Superficie
5.
Biomed Res Int ; 2016: 4183432, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27843942

RESUMEN

Objectives. To assess visually color-matching and blending-effect (BE) of a universal shade bulk-fill-resin-composite placed in resin-composite-models with different shades and cavity sizes and in natural teeth (extracted and patients' teeth). Materials and Methods. Resin-composite-discs (10 mm × 1 mm) were prepared of universal shade composite and resin-composite of shades: A1, A2, A3, A3.5, and A4. Spectrophotometric-color-measurement was performed to calculate color-difference (ΔE) between the universal shade and shaded-resin-composites discs and determine their translucency-parameter (TP). Visual assessment was performed by seven normal-color-vision-observers to determine the color-matching between the universal shade and each shade, under Illuminant D65. Color-matching visual scoring (VS) values were expressed numerically (1-5): 1: mismatch/totally unacceptable, 2: Poor-Match/hardly acceptable, 3: Good-Match/acceptable, 4: Close-Match/small-difference, and 5: Exact-Match/no-color-difference. Occlusal cavities of different sizes were prepared in teeth-like resin-composite-models with shades A1, A2, A3, A3.5, and A4. The cavities were filled by the universal shade composite. The same scale was used to score color-matching between the fillings and composite-models. BE was calculated as difference in mean-visual-scores in models and that of discs. Extracted teeth with two different class I-cavity sizes as well as ten patients' lower posterior molars with occlusal caries were prepared, filled by universal shade composite, and assessed similarly. Results. In models, the universal shade composite showed close matching in the different cavity sizes and surrounding shades (4 ≤ VS < 5) (BE = 0.6-2.9 in small cavities and 0.5-2.8 in large cavities). In extracted teeth, there was good-to-close color-matching (VS = 3.7-4.4 in small cavities, BE = 2.5-3.2) (VS = 3-3.5, BE = 1.8-2.3 in large cavities). In patients' molars, the universal shade composite showed good-matching (VS = 3-3.3, BE = -0.9-2.1). Conclusions. Color-matching of universal shade resin-composite was satisfactory rather than perfect in patients' teeth.


Asunto(s)
Caries Dental/cirugía , Diente Molar , Resinas Sintéticas/uso terapéutico , Extracción Dental , Color , Caries Dental/patología , Restauración Dental Permanente , Humanos , Diente Molar/patología , Diente Molar/cirugía , Resinas Sintéticas/química
6.
Oper Dent ; 32(3): 298-305, 2007.
Artículo en Inglés | MEDLINE | ID: mdl-17555183

RESUMEN

PURPOSE: This investigation evaluated the effect of glass and polyethylene fiber inserts on the microleakage of Class II composite restorations with gingival margins on root surfaces. METHODS: Fifty-four intact molars were sterilized with Gamma irradiation and mounted in acrylic bases. Class II slot cavities were made on both proximal sides of each tooth (3 mm wide, 1.5 mm deep) with the gingival margin on the root surface. The teeth were divided into nine groups, according to the technique of restoration and type of bonding agent. Filtek P-60 (3M/ESPE) was used to restore all cavities. Two types of fiber inserts were used: glass fiber (Ever Stick, StickTech) and polyethylene (Ribbond-THM), with three bonding agents being employed: Scotch Bond Multipurpose (3M/ESPE), Clearfil SE Bond (Kuraray) and Xeno IV (Dentsply). In the experimental groups, 3 mm long fiber inserts were inserted into restorations at the gingival seat. The control groups had no fiber inserts. The restorations were made incrementally and cured with LED light (UltraLume5, Ultradent). The restored teeth were stored in water for two weeks, then thermocycled for 3000 cycles (5 degrees C and 55 degrees C). The tooth surfaces were sealed with nail polish, except at the restoration margins. The teeth were immersed in 2% procion red dye solution, sectioned and dye penetration was assessed to determine the extent of microleakage according to a six-point scale. RESULTS: The fiber groups generally showed reduced microleakage scores compared to the control groups. The Clearfil SE Bond (Kuraray)/Filtek P-60 (3M/ESPE) combination produced the lowest degree of microleakage, irrespective of fiber type. However, the glass fiber groups were more consistent in reducing microleakage than the polyethylene groups. CONCLUSIONS: The use of fiber inserts significantly reduced gingival microleakage in Class II composite restorations with gingival margins in dentin, irrespective of the adhesive used. Clearfil SE Bond (Kuraray)/Filtek P60 (3M/ESPE) produced the lowest microleakage scores.


Asunto(s)
Resinas Compuestas , Recubrimiento de la Cavidad Dental/métodos , Filtración Dental/prevención & control , Restauración Dental Permanente/métodos , Adaptación Marginal Dental , Análisis del Estrés Dental , Recubrimientos Dentinarios , Vidrio , Humanos , Diente Molar , Transición de Fase , Polietilenos , Cementos de Resina
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA