Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Más filtros











Intervalo de año de publicación
1.
J Clin Med ; 12(16)2023 Aug 20.
Artículo en Inglés | MEDLINE | ID: mdl-37629450

RESUMEN

LEVEL OF EVIDENCE: Level 2. PURPOSE: To compare the safety and efficacy of vascular plug (VP) and vascular plug and polidocanol foam (VPPF) treatments for embolization in pelvic congestion syndrome (PCS). MATERIALS AND METHODS: A comparative, prospective, two-center study enrolled 50 women with PCS from January 2019 to January 2020. The patients were divided into two groups, and embolization was performed with VP (n = 25) and VPPF (n = 25) treatments. The mean age of the patients was 45.6 years ± 6.9. Three clinical parameters were assessed: abdominal pain, dyspareunia, and lower limb pain. The primary outcome (clinical success at 1 yr using a VAS), number of devices, procedure and fluoroscopy times, radiation doses, costs, and complications were compared. The participants were followed-up at 1, 3, 6, and 12 months. RESULTS: At the 1-year follow-up, clinical success did not significantly differ between the two groups (VP vs. VPPF) regarding the improvement of the symptoms analyzed (pelvic pain, dyspareunia, lower extremity pain, and other symptoms (p < 0.05)). The mean number of devices per case was 4 ± 1.1 for the VP group and 2 ± 0.31 for the VPPF group (p < 0.001). No major complications were recorded in either group. The VPPF group had a significantly longer fluoroscopy time (42.8 min ± 14.2 vs. 25.4 min ± 7) and longer radiation dose (VPPF air kerma 839.4 ± 513 vs. VP air kerma 658.4 mGy ± 355 (all p < 0.001)). CONCLUSIONS: Embolization for PCS resulted in pain relief in 90% of patients; the use of polidocanol did not demonstrate changes in the clinical outcome. The use of a VP alone was associated with decreased fluoroscopy time and radiation dose.

2.
J Clin Med ; 11(22)2022 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-36431234

RESUMEN

BACKGROUND: Congenital tracheomalacia is a pathology with no consensus of medical or surgical approach. The permanent nature and the major complications associated with metallic stents have limited their use over the years. The purpose of this study was to evaluate the feasibility of a helical stent design removal. METHODS: Ten dogs diagnosed with tracheal collapse and treated with the helical stent were involved in the study. Animals were classified into three groups depending on stent indwelling time. Prior to the removal, endoscopic evaluation was performed to assess endothelization grade, mucous accumulation, and the presence of stenosis. During the removal, bleeding, fracture, or impossibility of removal were noted. After the removal, all macroscopic mucosal changes were recorded. RESULTS: Technical success was 100%, without any complications. Complete epithelization of the stent was visualized in 7/10 animals. The removal procedure duration ranged from 2-12 min. At post-removal endoscopy, bleeding or epithelial damage, was visualized in any case. Stent fracture during removal occurred in one animal. CONCLUSIONS: The removal of a metallic stent with spiral geometry is feasible, simple, and without complications, regardless of the degree of neo-epithelialization.

3.
J Clin Med ; 11(11)2022 May 28.
Artículo en Inglés | MEDLINE | ID: mdl-35683436

RESUMEN

PURPOSE: The purpose of this study was to prospectively evaluate the efficacy and safety of a new, bare platinum, detachable microcoil as a metallic embolization agent in the treatment of hemorrhoidal disease. MATERIAL AND METHODS: This prospective single-center study evaluated a new, bare platinum, electrical, detachable microcoil (Prestige plus coil (Balt Montmorency France)) for use in vascular embolization in patients with hemorrhoidal disease. Between January 2020 and January 2021, 24 embolization procedures were performed in 21 patients (12 males, 9 females; mean age 44.3 ± 7.3). The inclusion criteria were: (a) participants with grade I, II and III hemorrhoidal disease on the Goligher classification; (b) patients older than 18 years of age with a score of greater than 4 on the French bleeding score (FBS) scale; (c) patients with scores greater than 2 on the scale of discomfort proposed by Tradi and Farfallah. (d) patients who underwent treatment that included the use of the new novel coil (Prestige plus coil (Balt)) as an embolic material. The exclusion criteria were participants who failed to provide informed consent and participants diagnosed with rectal bleeding due to other causes (cancer, fissures or others). Participants with severe renal insufficiency, non-correctable coagulation abnormalities and adverse reactions to the contrast medium not correctable with medication were also excluded. The symptoms, technical aspects, the transarterial approach, clinical and technical success complications and short-term outcomes were assessed. RESULTS: Technical success was obtained in 100% of the cases. Seventeen (80.9%) patients experienced improvements in their hemorrhoidal disease. The VAS and QL scores improved by 4 and 1.5 points (81.2% and 87.5%), respectively, after embolization (pV: 0001). Three (14.2%) patients underwent a second embolization due to rebleeding. One patient (4.7%) underwent surgery. No major complications were observed. Three patients had minor complications. The assessment of subjective post-treatment symptoms and QL surveys showed significant differences from the baseline survey. Likewise, the measurement of the degree of satisfaction using a telephone survey at 12 months revealed a high degree of patient satisfaction over 10 points (mean 8.3 ± 1.1). CONCLUSIONS: The present study demonstrates that the use of the new, platinum, detachable, electrical microcoil is safe and well-tolerated in the treatment of hemorrhoidal disease. KEY POINTS: Catheter-directed hemorrhoidal dearterialization (CDHD) is the procedure of embolization with embolic agents for the treatment of internal hemorrhoids. CDHD is a simple and safe procedure that is accepted by patients and preserves the anal sphincter; it presents few complications when metal devices or microspheres are used as embolic agents. As the recommended embolization agent in treatments, the Prestige electrical, detachable coil is a safe, easy-to-use and effective arterial embolic device.

8.
Rev Esp Enferm Dig ; 107(12): 766-7, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26671592

RESUMEN

Abernethy malformation is a rare abnormal embryological development of splanchnic venous system characterised by the presence of a congenital extrahepatic portosystemic shunt. We present a rare case of an adult male patient that was admitted with severe lower gastrointestinal bleeding, requiring multiple blood transfusions. The patient's medical history and the laboratory tests performed led to the misdiagnosis of a congenital Abernethy malformation. We present a rare case, discussing the reasons for the misdiagnosis and we conclude that management of clinical data and imaging are highly important to discard these types of congenital malformations that can mimic a portal hypertension condition.


Asunto(s)
Errores Diagnósticos , Hemorragia Gastrointestinal/etiología , Hipertensión Portal/diagnóstico , Cirrosis Hepática/diagnóstico , Vena Porta/anomalías , Derivación Portosistémica Intrahepática Transyugular , Malformaciones Vasculares/diagnóstico , Adulto , Hemorragia Gastrointestinal/cirugía , Humanos , Masculino , Vena Porta/cirugía , Recto , Malformaciones Vasculares/complicaciones , Malformaciones Vasculares/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA