Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Más filtros











Intervalo de año de publicación
1.
Acta Ortop Mex ; 37(3): 152-158, 2023.
Artículo en Español | MEDLINE | ID: mdl-38052436

RESUMEN

INTRODUCTION: all-in meniscal suture devices have evolved and simplified meniscal repair. In this study we will formulate the following research questions: what is the rate of survival and failure? What are the risk factors associated with failure? And what are the functional results after meniscal repair surgery? MATERIAL AND METHODS: ambispective study from 2001 to 2021 of patients with repairable meniscal injury with all-in meniscal suture devices. The survival and failure ratio were obtained with the Kaplan-Meier test, the risk factors associated with meniscal suture failure were assessed with the logistic regression test, and the pre- and post-surgical functional results were estimated with the test. t-Student. RESULTS: in 20 years of follow-up of 316 menisci repaired with all-in meniscal sutures, a survival rate of 95.9% was obtained. The absence of injury to the anterior horn of the meniscus was shown to be a protective factor [OR = 0.12], together with not practicing impact sports [OR = 0.2]. Post-surgery IKDC and Tegner-Lysholm results were shown to be very good to excellent (p < 0.0001). CONCLUSION: all-in meniscal suture devices are and will continue to be front-line weapons in the repair of meniscal tears. In 20 years of follow-up, a lower failure rate was evidenced, associated with excellent functional results.


INTRODUCCIÓN: los dispositivos de suturas meniscal todo adentro han evolucionado y simplificado la reparación meniscal. En este estudio formulamos las siguientes preguntas de investigación: ¿cuál es la tasa de supervivencia y falla?, ¿cuáles son los factores de riesgo asociado a falla? y ¿cuáles son los resultados funcionales posterior a la cirugía de reparación meniscal? MATERIAL Y MÉTODOS: estudio ambispectivo desde el 2001 al 2021 de pacientes con lesión meniscal reparable con dispositivos meniscales de sutura todo adentro. La razón de supervivencia y falla se obtuvo con el test de Kaplan-Meier, los factores de riesgo asociado con falla de la sutura meniscal se valoraron con el test de regresión logística y los resultados funcionales pre y postquirúrgicos fueron estimados con la prueba t-Student. RESULTADOS: en 20 años de seguimiento de 316 menisco reparados con suturas meniscal todo adentro se obtuvo que la razón de supervivencia de 95.9%. La ausencia de lesión del cuerno anterior del menisco se mostró como un factor protector [OR = 0.12], junto a la no práctica de deportes de impacto [OR = 0.2]. Se mostraron resultados del IKDC y Tegner-Lysholm posterior a la cirugía de muy buenos a excelentes (p < 0.0001). CONCLUSIÓN: los dispositivos de sutura de meniscal todo adentro son y seguirán siendo armas de primera línea en la reparación de las roturas meniscales. En 20 años de seguimiento se evidenció una menor tasa de falla, asociados con excelentes resultados funcionales.


Asunto(s)
Meniscos Tibiales , Lesiones de Menisco Tibial , Humanos , Artroscopía , Meniscos Tibiales/cirugía , Estudios Retrospectivos , Técnicas de Sutura , Suturas , Lesiones de Menisco Tibial/cirugía
2.
Acta ortop. mex ; 37(3): 152-158, may.-jun. 2023. tab, graf
Artículo en Español | LILACS-Express | LILACS | ID: biblio-1556750

RESUMEN

Resumen: Introducción: los dispositivos de suturas meniscal todo adentro han evolucionado y simplificado la reparación meniscal. En este estudio formulamos las siguientes preguntas de investigación: ¿cuál es la tasa de supervivencia y falla?, ¿cuáles son los factores de riesgo asociado a falla? y ¿cuáles son los resultados funcionales posterior a la cirugía de reparación meniscal? Material y métodos: estudio ambispectivo desde el 2001 al 2021 de pacientes con lesión meniscal reparable con dispositivos meniscales de sutura todo adentro. La razón de supervivencia y falla se obtuvo con el test de Kaplan-Meier, los factores de riesgo asociado con falla de la sutura meniscal se valoraron con el test de regresión logística y los resultados funcionales pre y postquirúrgicos fueron estimados con la prueba t-Student. Resultados: en 20 años de seguimiento de 316 menisco reparados con suturas meniscal todo adentro se obtuvo que la razón de supervivencia de 95.9%. La ausencia de lesión del cuerno anterior del menisco se mostró como un factor protector [OR = 0.12], junto a la no práctica de deportes de impacto [OR = 0.2]. Se mostraron resultados del IKDC y Tegner-Lysholm posterior a la cirugía de muy buenos a excelentes (p < 0.0001). Conclusión: los dispositivos de sutura de meniscal todo adentro son y seguirán siendo armas de primera línea en la reparación de las roturas meniscales. En 20 años de seguimiento se evidenció una menor tasa de falla, asociados con excelentes resultados funcionales.


Abstract: Introduction: all-in meniscal suture devices have evolved and simplified meniscal repair. In this study we will formulate the following research questions: what is the rate of survival and failure? What are the risk factors associated with failure? And what are the functional results after meniscal repair surgery? Material and methods: ambispective study from 2001 to 2021 of patients with repairable meniscal injury with all-in meniscal suture devices. The survival and failure ratio were obtained with the Kaplan-Meier test, the risk factors associated with meniscal suture failure were assessed with the logistic regression test, and the pre- and post-surgical functional results were estimated with the test. t-Student. Results: in 20 years of follow-up of 316 menisci repaired with all-in meniscal sutures, a survival rate of 95.9% was obtained. The absence of injury to the anterior horn of the meniscus was shown to be a protective factor [OR = 0.12], together with not practicing impact sports [OR = 0.2]. Post-surgery IKDC and Tegner-Lysholm results were shown to be very good to excellent (p < 0.0001). Conclusion: all-in meniscal suture devices are and will continue to be front-line weapons in the repair of meniscal tears. In 20 years of follow-up, a lower failure rate was evidenced, associated with excellent functional results.

3.
Acta Ortop Mex ; 36(2): 92-96, 2022.
Artículo en Español | MEDLINE | ID: mdl-36481549

RESUMEN

INTRODUCTION: the tibial slope has been identified as one of the factors associated with graft failure after anterior cruciate ligament (ACL) reconstruction; however, its relationship with functional results has been little studied. The main purpose of this study is to determine the effect of the tibial slope on functional recovery in patients undergoing reconstruction of the anterior cruciate ligament. MATERIAL AND METHODS: we included patients with a diagnosis of anterior cruciate ligament injury undergoing primary reconstruction, from May 2018 to May 2019, who had a complete radiographic and clinical record; also, the scores from questionnaires of the International Knee Documentation Committee (IKDC) and Lysholm scores were collected pre surgical procedures and throughout the one-year follow-up. The measurement of the tibial slope was performed in lateral knee X-rays from the electronic clinical record. A descriptive analysis of first intention was done, and to achieve the objectives, we compared 25 patients who had normal tibial slope that were selected randomly with 25 patients who had increased tibial slope. RESULTS: a total of 98 patients were included, 73 had a normal tibial slope (equal to or less than 12 degrees) and 25 with an increased tibial slope (greater than 12 degrees), the average age in both groups was 28.43 years for the group with normal tibial slope and 28.26 for patients with increased tibial slope. Regarding the functional assessment, the IKDC and Lysholm scores at the end of the follow-up were better for patients with normal tibial slope. Graft failure was only identified in the group with increased tibial slope. On the other hand, the comparative analysis with the control group randomly selected who had normal tibial slope, showed a better functional result assessed by IKDC score at the end of the follow-up for the group with normal tibial slope. CONCLUSION: patients undergoing ACL reconstruction and increased Tibial Slope have an inferior functional result at one year of follow-up assessed by IKDC, when compared with patients with normal tibial slope.


INTRODUCCIÓN: el slope tibial (inclinación) se ha identificado como uno de los factores asociados a la falla del injerto tras una reconstrucción de ligamento cruzado anterior (LCA); sin embargo, su relación con los resultados funcionales ha sido poco estudiada. El objetivo de este estudio es determinar el efecto del slope tibial en la recuperación funcional, en pacientes sometidos a reconstrucción de LCA. MATERIAL Y MÉTODOS: se incluyeron los pacientes con lesión de LCA sometidos a reconstrucción primaria, de Mayo de 2018 a Mayo de 2019, midiendo el slope tibial y recabando los puntajes de IKDC y Lysholm. Se elaboró un análisis descriptivo de primera intención y para alcanzar los objetivos se realizó una comparativa de 25 pacientes con slope tibial normal seleccionados aleatoriamente contra 25 pacientes con slope tibial aumentado. RESULTADOS: se incluyeron 98 pacientes, 73 contaban con un slope tibial normal y 25 con un slope tibial aumentado. Los puntajes de IKDC y Lysholm al final del seguimiento fueron mejores en los pacientes con slope tibial normal. La falla del injerto sólo se identificó en el grupo con slope tibial aumentado. Por otro lado, al análisis comparativo con el grupo control demostró un mejor resultado funcional al final del seguimiento valorado por IKDC en el grupo con slope tibial normal. CONCLUSIÓN: los pacientes sometidos a reconstrucción de LCA y slope tibial aumentado tienen un resultado funcional inferior al año de seguimiento evaluado por IKDC en comparación con pacientes con slope tibial dentro de parámetros normales.


Asunto(s)
Reconstrucción del Ligamento Cruzado Anterior , Adulto , Humanos
4.
Acta ortop. mex ; 36(2): 92-96, mar.-abr. 2022. tab, graf
Artículo en Español | LILACS-Express | LILACS | ID: biblio-1505516

RESUMEN

Resumen: Introducción: El slope tibial (inclinación) se ha identificado como uno de los factores asociados a la falla del injerto tras una reconstrucción de ligamento cruzado anterior (LCA); sin embargo, su relación con los resultados funcionales ha sido poco estudiada. El objetivo de este estudio es determinar el efecto del slope tibial en la recuperación funcional, en pacientes sometidos a reconstrucción de LCA. Material y métodos: Se incluyeron los pacientes con lesión de LCA sometidos a reconstrucción primaria, de Mayo de 2018 a Mayo de 2019, midiendo el slope tibial y recabando los puntajes de IKDC y Lysholm. Se elaboró un análisis descriptivo de primera intención y para alcanzar los objetivos se realizó una comparativa de 25 pacientes con slope tibial normal seleccionados aleatoriamente contra 25 pacientes con slope tibial aumentado. Resultados: Se incluyeron 98 pacientes, 73 contaban con un slope tibial normal y 25 con un slope tibial aumentado. Los puntajes de IKDC y Lysholm al final del seguimiento fueron mejores en los pacientes con slope tibial normal. La falla del injerto sólo se identificó en el grupo con slope tibial aumentado. Por otro lado, al análisis comparativo con el grupo control demostró un mejor resultado funcional al final del seguimiento valorado por IKDC en el grupo con slope tibial normal. Conclusión: Los pacientes sometidos a reconstrucción de LCA y slope tibial aumentado tienen un resultado funcional inferior al año de seguimiento evaluado por IKDC en comparación con pacientes con slope tibial dentro de parámetros normales.


Abstract: Introduction: The tibial slope has been identified as one of the factors associated with graft failure after anterior cruciate ligament (ACL) reconstruction; however, its relationship with functional results has been little studied. The main purpose of this study is to determine the effect of the tibial slope on functional recovery in patients undergoing reconstruction of the anterior cruciate ligament. Material and methods: We included patients with a diagnosis of anterior cruciate ligament injury undergoing primary reconstruction, from May 2018 to May 2019, who had a complete radiographic and clinical record; also, the scores from questionnaires of the International Knee Documentation Committee (IKDC) and Lysholm scores were collected pre surgical procedures and throughout the one-year follow-up. The measurement of the tibial slope was performed in lateral knee X-rays from the electronic clinical record. A descriptive analysis of first intention was done, and to achieve the objectives, we compared 25 patients who had normal tibial slope that were selected randomly with 25 patients who had increased tibial slope. Results: A total of 98 patients were included, 73 had a normal tibial slope (equal to or less than 12 degrees) and 25 with an increased tibial slope (greater than 12 degrees), the average age in both groups was 28.43 years for the group with normal tibial slope and 28.26 for patients with increased tibial slope. Regarding the functional assessment, the IKDC and Lysholm scores at the end of the follow-up were better for patients with normal tibial slope. Graft failure was only identified in the group with increased tibial slope. On the other hand, the comparative analysis with the control group randomly selected who had normal tibial slope, showed a better functional result assessed by IKDC score at the end of the follow-up for the group with normal tibial slope. Conclusion: Patients undergoing ACL reconstruction and increased Tibial Slope have an inferior functional result at one year of follow-up assessed by IKDC, when compared with patients with normal tibial slope.

5.
Acta ortop. mex ; 35(4): 327-330, jul.-ago. 2021. graf
Artículo en Español | LILACS-Express | LILACS | ID: biblio-1374195

RESUMEN

Resumen: Introducción: En la reconstrucción de ligamento cruzado anterior se intenta reproducir ligamento nativo, realizar túneles independientes, optimizar los puntos de entrada y la efectividad de la anatomía; hacer mediciones radiográficas de rodilla, identificar la posición del túnel femoral y tibial en pacientes operados de reconstrucción de ligamento cruzado anterior con técnica anatómica. Material y métodos: Se identificaron pacientes en el período de Enero de 2018 a Diciembre de 2019. Se evaluaron de manera retrospectiva 98 pacientes. Mediciones radiográficas en fémur: se determinó el ángulo de inclinación del túnel, el sitio de inserción con respecto a la línea de Blumensaat y la distancia transósea. En tibia: la ubicación en porcentaje de la localización de platillo tibial en proyección anteroposterior y lateral, ángulo de túnel tibial. Resultados: Los pacientes postoperados fueron 98, masculinos (75.5%) y femeninos (24.5%). Postoperados en el año 2018 (57.15%) y en 2019 (42.85%). Rango de edad: el grupo afectado fue de 21-25 años, lado afectado: derecho en 57.15%. Mediciones radiográficas en fémur: el ángulo de inclinación del túnel fue de 45o, el porcentaje en la línea de Blumensaat fue de 20% y la distancia transósea fue 3.43 cm. En tibia la distancia porcentual en proyección anteroposterior fue de 44% y lateral de 28%. El ángulo en túnel tibial en proyección anteroposterior fue de 73º y lateral de 114º. Conclusión: La técnica anatómica es una buena opción para efectuar túneles con posición anatómica óptima. Realizar túneles independientes permite mejorar la cobertura de la huella anatómica normal, aumenta los grados y la inclinación de túneles y provoca lesiones agregadas.


Abstract: Introduction: Reconstruction of the anterior cruciate ligament attempts to reproduce the native ligament; make independent tunnels optimize the entry points and effectiveness the anatomy. Perform radiographic measurements of the knee, identify position of femoral and tibial tunnels in patients operated for reconstruction of anterior cruciate ligament with anatomical technique. Material and methods: Patients were identified in the period January 2018 to December 2019. 98 patients were retrospectively evaluated. Radiographic measurements in the femur, the inclination angle of the tunnel, the insertion site with respect to the Blumensaat line and the transosseous distance were determined. In tibia, the location in percentage of the tibial plateau location in anteroposterior and lateral view, tibial tunnel angle. Results: Postoperative patients were 98. (75.5%) male, female (24.5%). Postoperative in 2018 (57.15%) and 2019 (42.85%) Age range: affected group was 21-25 years, right side affected in 57.15%; Radiographic measurements in femur, the angle of inclination of the tunnel was 45o, percentage in the Blumensaat line was 20%, and the transosseous distance was 3.43 cm. In tibia the percentage distance in anteroposterior projection was 44%, and lateral 28%, The angle in tibial tunnel anteroposterior projection of 73 degrees, and lateral 114. Conclusion: The anatomical technique is a good option to perform tunnels with an optimal anatomical position. By making independent tunnels it allows to improve coverage of normal antomic footprint. Increases degrees and inclination of tunnels, causes added injuries.

6.
Acta Ortop Mex ; 35(4): 327-330, 2021.
Artículo en Español | MEDLINE | ID: mdl-35139591

RESUMEN

INTRODUCTION: Reconstruction of the anterior cruciate ligament attempts to reproduce the native ligament; make independent tunnels optimize the entry points and effectiveness the anatomy. Perform radiographic measurements of the knee, identify position of femoral and tibial tunnels in patients operated for reconstruction of anterior cruciate ligament with anatomical technique. MATERIAL AND METHODS: Patients were identified in the period January 2018 to December 2019. 98 patients were retrospectively evaluated. Radiographic measurements in the femur, the inclination angle of the tunnel, the insertion site with respect to the Blumensaat line and the transosseous distance were determined. In tibia, the location in percentage of the tibial plateau location in anteroposterior and lateral view, tibial tunnel angle. RESULTS: Postoperative patients were 98. (75.5%) male, female (24.5%). Postoperative in 2018 (57.15%) and 2019 (42.85%) Age range: affected group was 21-25 years, right side affected in 57.15%; Radiographic measurements in femur, the angle of inclination of the tunnel was 45o, percentage in the Blumensaat line was 20%, and the transosseous distance was 3.43 cm. In tibia the percentage distance in anteroposterior projection was 44%, and lateral 28%, The angle in tibial tunnel anteroposterior projection of 73 degrees, and lateral 114. CONCLUSION: The anatomical technique is a good option to perform tunnels with an optimal anatomical position. By making independent tunnels it allows to improve coverage of normal antomic footprint. Increases degrees and inclination of tunnels, causes added injuries.


INTRODUCCIÓN: En la reconstrucción de ligamento cruzado anterior se intenta reproducir ligamento nativo, realizar túneles independientes, optimizar los puntos de entrada y la efectividad de la anatomía; hacer mediciones radiográficas de rodilla, identificar la posición del túnel femoral y tibial en pacientes operados de reconstrucción de ligamento cruzado anterior con técnica anatómica. MATERIAL Y MÉTODOS: Se identificaron pacientes en el período de Enero de 2018 a Diciembre de 2019. Se evaluaron de manera retrospectiva 98 pacientes. Mediciones radiográficas en fémur: se determinó el ángulo de inclinación del túnel, el sitio de inserción con respecto a la línea de Blumensaat y la distancia transósea. En tibia: la ubicación en porcentaje de la localización de platillo tibial en proyección anteroposterior y lateral, ángulo de túnel tibial. RESULTADOS: Los pacientes postoperados fueron 98, masculinos (75.5%) y femeninos (24.5%). Postoperados en el año 2018 (57.15%) y en 2019 (42.85%). Rango de edad: el grupo afectado fue de 21-25 años, lado afectado: derecho en 57.15%. Mediciones radiográficas en fémur: el ángulo de inclinación del túnel fue de 45o, el porcentaje en la línea de Blumensaat fue de 20% y la distancia transósea fue 3.43 cm. En tibia la distancia porcentual en proyección anteroposterior fue de 44% y lateral de 28%. El ángulo en túnel tibial en proyección anteroposterior fue de 73º y lateral de 114º. CONCLUSIÓN: La técnica anatómica es una buena opción para efectuar túneles con posición anatómica óptima. Realizar túneles independientes permite mejorar la cobertura de la huella anatómica normal, aumenta los grados y la inclinación de túneles y provoca lesiones agregadas.


Asunto(s)
Lesiones del Ligamento Cruzado Anterior , Reconstrucción del Ligamento Cruzado Anterior , Adulto , Ligamento Cruzado Anterior/diagnóstico por imagen , Ligamento Cruzado Anterior/cirugía , Femenino , Fémur/diagnóstico por imagen , Fémur/cirugía , Humanos , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/cirugía , Masculino , Estudios Retrospectivos , Tibia/diagnóstico por imagen , Tibia/cirugía , Adulto Joven
7.
Acta Ortop Mex ; 34(1): 6-9, 2020.
Artículo en Español | MEDLINE | ID: mdl-33230992

RESUMEN

INTRODUCTION: ATC can cause considerable blood loss. To reduce the need for blood transfusion, various preoperative techniques such as administration of tranexamic acid (ATX) are used. OBJECTIVE: to demonstrate that the use of ATX decreases the need for allogeneic blood transfusion in patients operated on ATC. MATERIAL AND METHODS: Prospective, observational, descriptive study, used to observe the allogeneic blood transfusion rate in patients who underwent unilateral primary ATC from May 2016 to December 2017. ATX was applied preoperatively and after 24 hours a blood count was taken and the need for blood transfusion was assessed. RESULTS: A total of 70 patients were included in the study. The average postoperative Hb 11.7 mg/dl with a range of 9.2 to 14.9 mg/dl and an average Ht of 37.1% with a range of 30.2 to 44.2%. None of the patients required allogeneic blood transfusión. CONCLUSIONS: This study demonstrates how ATX is a transoperative strategy to reduce the need for allogeneic blood transfusion in patients undergoing primary ATC.


INTRODUCCIÓN: La artroplastía total de cadera (ATC) puede causar una pérdida considerable de sangre. Para reducir la necesidad de transfusión de sangre se utilizan diversas técnicas preoperatorias como la administración de ácido tranexámico (ATX). OBJETIVO: Demostrar que el uso de ATX disminuye la necesidad de transfusión de sangre alogénica en pacientes operados de ATC. MATERIAL Y MÉTODOS: estudio prospectivo, observacional, descriptivo, utilizado para observar la tasa de transfusión de sangre alogénica en pacientes a quienes se les practicó ATC primaria unilateral de Mayo de 2016 a Diciembre de 2017. A los pacientes incluidos en el estudio se les aplicó ATX preoperatoriamente, a las 24 horas se tomó una biometría hemática y se valoró la necesidad de transfusión sanguínea. RESULTADOS: Se incluyó un total de 70 pacientes en el estudio. La Hb promedio postquirúrgica 11.7 mg/dl con un rango de 9.2 a 14.9 mg/dl y un Hto promedio de 37.1% con un rango de 30.2 a 44.2%. Ninguno de los pacientes requirió de transfusión de sangre alogénica. CONCLUSIONES: En este estudio se demuestra cómo el ATX es una estrategia transoperatoria para reducir la necesidad de transfusión de sangre alogénica en pacientes a quienes se realiza una ATC primaria.


Asunto(s)
Antifibrinolíticos , Artroplastia de Reemplazo de Cadera , Ácido Tranexámico , Antifibrinolíticos/uso terapéutico , Pérdida de Sangre Quirúrgica/prevención & control , Transfusión Sanguínea , Humanos , Estudios Prospectivos , Ácido Tranexámico/uso terapéutico
8.
Acta ortop. mex ; 34(1): 6-9, ene.-feb. 2020.
Artículo en Español | LILACS | ID: biblio-1345077

RESUMEN

Resumen: Introducción: La artroplastía total de cadera (ATC) puede causar una pérdida considerable de sangre. Para reducir la necesidad de transfusión de sangre se utilizan diversas técnicas preoperatorias como la administración de ácido tranexámico (ATX). Objetivo: Demostrar que el uso de ATX disminuye la necesidad de transfusión de sangre alogénica en pacientes operados de ATC. Material y métodos: estudio prospectivo, observacional, descriptivo, utilizado para observar la tasa de transfusión de sangre alogénica en pacientes a quienes se les practicó ATC primaria unilateral de Mayo de 2016 a Diciembre de 2017. A los pacientes incluidos en el estudio se les aplicó ATX preoperatoriamente, a las 24 horas se tomó una biometría hemática y se valoró la necesidad de transfusión sanguínea. Resultados: Se incluyó un total de 70 pacientes en el estudio. La Hb promedio postquirúrgica 11.7 mg/dl con un rango de 9.2 a 14.9 mg/dl y un Hto promedio de 37.1% con un rango de 30.2 a 44.2%. Ninguno de los pacientes requirió de transfusión de sangre alogénica. Conclusiones: En este estudio se demuestra cómo el ATX es una estrategia transoperatoria para reducir la necesidad de transfusión de sangre alogénica en pacientes a quienes se realiza una ATC primaria.


Abstract: Introduction: ATC can cause considerable blood loss. To reduce the need for blood transfusion, various preoperative techniques such as administration of tranexamic acid (ATX) are used. Objective: to demonstrate that the use of ATX decreases the need for allogeneic blood transfusion in patients operated on ATC. Material and methods: Prospective, observational, descriptive study, used to observe the allogeneic blood transfusion rate in patients who underwent unilateral primary ATC from May 2016 to December 2017. ATX was applied preoperatively and after 24 hours a blood count was taken and the need for blood transfusion was assessed. Results: A total of 70 patients were included in the study. The average postoperative Hb 11.7 mg/dl with a range of 9.2 to 14.9 mg/dl and an average Ht of 37.1% with a range of 30.2 to 44.2%. None of the patients required allogeneic blood transfusión. Conclusions: This study demonstrates how ATX is a transoperative strategy to reduce the need for allogeneic blood transfusion in patients undergoing primary ATC.


Asunto(s)
Humanos , Ácido Tranexámico/uso terapéutico , Artroplastia de Reemplazo de Cadera , Antifibrinolíticos/uso terapéutico , Transfusión Sanguínea , Estudios Prospectivos , Pérdida de Sangre Quirúrgica/prevención & control
9.
Acta ortop. mex ; 33(6): 352-356, nov.-dic. 2019. tab
Artículo en Español | LILACS | ID: biblio-1345059

RESUMEN

Resumen: Introducción: La reducción de la pérdida sanguínea y de las transfusiones en pacientes operados de artroplastía total de rodilla (ATR) primaria se asocia a un mejor resultado clínico y funcional. El uso de ácido tranexámico (ATX) es uno de los métodos utilizados para disminuir ese sangrado. Material y métodos: Se compararon los resultados en hemoglobina (Hb), hematocrito (Hto), tasa de sangrado y de transfusión, tiempo quirúrgico y dolor entre los grupos A (con ATX) y grupo B (sin ATX) posterior a la ATR. Resultados: Se encontraron diferencias estadísticamente significativas en la disminución del sangrado transquirúrgico y periquirúrgico global, en la disminución de la Hb a las 24 horas, en la tasa de transfusión, en el tiempo quirúrgico y en el dolor a la deambulación a favor del grupo A. Discusión: En México no hay literatura publicada sobre el uso de ATX en pacientes operados de ATR. A pesar del uso cada vez más común del ATX, la mejor dosis y vía de administración sigue siendo un tema controversial. Conclusión: El uso de ATX en el esquema propuesto es un método seguro y eficaz para disminuir la tasa de sangrado y de transfusiones en los pacientes operados de ATR.


Abstract: Background: Reducing blood loss and transfusions in patients operated on primary TKR is associated with a better clinical and functional outcome. The use of Tranexamic Acid (ATX) is one of the methods used to decrease that bleeding. Material and methods: Results in Hb, Hto, rate of bleeding and transfusion, surgical time and pain between groups A (with ATX) and group B (without tranexamic acid) after TKR are compared. Results: Statistically significant differences were found during surgery and perisurgical bleeding, in the decrease of Hb at 24 hours, transfusion rate, surgical time and pain to wandering in favor of group A. Discussion: There are no published studies in Mexico on the use of ATX in patients operated on TKR. We consider its use to be increasingly common, the optimal dose and route of administration remains a controversial topic. Conclusion: The use of ATX in the proposed scheme is safe and effective in reducing the rate of bleeding and transfusions in patients operated on ATR.


Asunto(s)
Humanos , Artroplastia de Reemplazo de Rodilla , Antifibrinolíticos , Ácido Tranexámico , Pérdida de Sangre Quirúrgica , Hemorragia Posoperatoria , México
10.
Acta Ortop Mex ; 33(6): 352-356, 2019.
Artículo en Español | MEDLINE | ID: mdl-32767875

RESUMEN

BACKGROUND: Reducing blood loss and transfusions in patients operated on primary TKR is associated with a better clinical and functional outcome. The use of Tranexamic Acid (ATX) is one of the methods used to decrease that bleeding. MATERIAL AND METHODS: Results in Hb, Hto, rate of bleeding and transfusion, surgical time and pain between groups A (with ATX) and group B (without tranexamic acid) after TKR are compared. Results: Statistically significant differences were found during surgery and perisurgical bleeding, in the decrease of Hb at 24 hours, transfusion rate, surgical time and pain to wandering in favor of group A. DISCUSSION: There are no published studies in Mexico on the use of ATX in patients operated on TKR. We consider its use to be increasingly common, the optimal dose and route of administration remains a controversial topic. CONCLUSION: The use of ATX in the proposed scheme is safe and effective in reducing the rate of bleeding and transfusions in patients operated on ATR.


INTRODUCCIÓN: La reducción de la pérdida sanguínea y de las transfusiones en pacientes operados de artroplastía total de rodilla (ATR) primaria se asocia a un mejor resultado clínico y funcional. El uso de ácido tranexámico (ATX) es uno de los métodos utilizados para disminuir ese sangrado. MATERIAL Y MÉTODOS: Se compararon los resultados en hemoglobina (Hb), hematocrito (Hto), tasa de sangrado y de transfusión, tiempo quirúrgico y dolor entre los grupos A (con ATX) y grupo B (sin ATX) posterior a la ATR. RESULTADOS: Se encontraron diferencias estadísticamente significativas en la disminución del sangrado transquirúrgico y periquirúrgico global, en la disminución de la Hb a las 24 horas, en la tasa de transfusión, en el tiempo quirúrgico y en el dolor a la deambulación a favor del grupo A. DISCUSIÓN: En México no hay literatura publicada sobre el uso de ATX en pacientes operados de ATR. A pesar del uso cada vez más común del ATX, la mejor dosis y vía de administración sigue siendo un tema controversial. CONCLUSIÓN: El uso de ATX en el esquema propuesto es un método seguro y eficaz para disminuir la tasa de sangrado y de transfusiones en los pacientes operados de ATR.


Asunto(s)
Antifibrinolíticos , Artroplastia de Reemplazo de Rodilla , Pérdida de Sangre Quirúrgica , Humanos , México , Hemorragia Posoperatoria , Ácido Tranexámico
11.
Acta Ortop Mex ; 26(6): 347-53, 2012.
Artículo en Español | MEDLINE | ID: mdl-24712200

RESUMEN

INTRODUCTION: Ligamentoplasty is a posterior dynamic stabilization method. The purpose of this study is to compare the incidence of adjacent segment disease in patients undergoing decompression and ligamentoplasty versus patients with standard 360 degrees arthrodesis. MATERIAL AND METHODS: Two groups were studied, each with 15 patients. The first group underwent recalibration with fixation (Group A) and the second group recalibration with ligamentoplasty (Group L). The occurrence of adjacent segment degeneration was assessed, together with the presence of adjacent segment disease in both groups. The statistical analysis was performed with the SPSS 17.0 software. RESULTS: Both techniques showed a statistically significant clinical improvement at the six-month postoperative follow-up (p = 0.001). Radiographic findings showed a higher translational instability index at the one-year follow-up in the arthrodesis group. No statistical difference was found in the clinical course or in the rest of the radiographic variables at the 3-year comparison between both groups. The rate of adjacent segment degeneration in Group A was 33.3%, compared with 20% in Group L at the one-year follow-up. Until now, there have been two cases of radiculopathy, one in Group L and one in Group A, both with adjacent segment disease. CONCLUSION: At the 3-year follow-up it is not possible to say that ligamentoplasty, unlike 360 degrees arthrodesis, decreases the rate of adjacent segment disease. However, this technique has promising results.


Asunto(s)
Vértebras Lumbares , Fusión Vertebral/métodos , Estenosis Espinal/cirugía , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Procedimientos Ortopédicos/métodos , Estudios Prospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA