Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
4.
Vestn Khir Im I I Grek ; 128(6): 7-11, 1982 Jun.
Artículo en Ruso | MEDLINE | ID: mdl-7123773

RESUMEN

Experiments in dogs have shown that ablation of one lung is followed by increased coagulative activity and decreased fibrinolytic activity of tissues of the thoracic cavity, devoid of pleura which is responsible for better formation of coagulated hemo-and fibrinothorax. The balloon pleural obturator is shown to change coagulative properties of the tissues thus preventing blood coagulation and fibrin formation. Bringing of fibrin to the bronchus stump contributes to hermetization of the bronchus stump.


Asunto(s)
Coagulación Sanguínea , Bronquios/fisiopatología , Neumonectomía , Tórax/fisiopatología , Animales , Coagulación Sanguínea/efectos de los fármacos , Perros , Fibrinógeno/administración & dosificación , Fibrinólisis/efectos de los fármacos , Humanos , Pleura/fisiopatología , Pleura/cirugía , Periodo Posoperatorio
5.
Ophthalmic Surg ; 11(12): 850-5, 1980 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-7207957

RESUMEN

A new endoillumination infusion cannula has been developed that allows for wide field illumination of the retina during pars plana vitrectomy surgery. This frees the surgeon from having to use one of the intravitreal probes for endoillumination when using the bimanual technique in pars plana vitrectomy. This innovative endoillumination source also can be used with indirect ophthalmoscopy, at surgery, avoiding the glare generated by the indirect ophthalmoscope's light beam interacting with the corneal surface and the condensing lens surfaces.


Asunto(s)
Cateterismo/instrumentación , Tecnología de Fibra Óptica/instrumentación , Instrumentos Quirúrgicos/normas , Cuerpo Vítreo/cirugía , Humanos , Luz , Oftalmoscopios , Irrigación Terapéutica/instrumentación
6.
Ophthalmic Surg ; 11(10): 698-700, 1980 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-7454208

RESUMEN

A newly modified endoillumination probe using the Ocutome handle has been developed that has 2.5 times more total light output and over four times more light intensity than the conventional endoillumination probe. The new probe is particularly useful in situations where there is extremely dense vitreous hemorrhage and when one requires additional light for 16-mm cinematography.


Asunto(s)
Cuerpo Ciliar/cirugía , Iluminación , Oftalmología/instrumentación , Cuerpo Vítreo/cirugía , Humanos
7.
Ophthalmic Surg ; 11(9): 599-603, 1980 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-7422245

RESUMEN

A fixed contact lens retaining ring with its own irrigation system is described for use in pars plana vitrectomy. The advantages and disadvantages of this system are compared with the hand-held contact lens instruments.


Asunto(s)
Lentes de Contacto , Cuerpo Vítreo/cirugía , Humanos , Oftalmología/instrumentación
17.
Vestn Khir Im I I Grek ; 116(5): 24-6, 1976 May.
Artículo en Ruso | MEDLINE | ID: mdl-951907

RESUMEN

The authors suggested and employed in 34 patients a balloon-devise, that is inflated in the pleural cavity following a removal of the lung. This lessens plasma and hemorrhages, thus contributing to the prophylaxis of postoperative empyemas.


Asunto(s)
Hemostasis Quirúrgica/instrumentación , Hemotórax/prevención & control , Humanos , Pleura , Neumonectomía , Cuidados Posoperatorios , Complicaciones Posoperatorias/prevención & control
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA