1.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 78(5): 449-463, 2022 May 20.
Artículo en Japonés | MEDLINE | ID: mdl-35400711

RESUMEN

In computed tomography (CT) systems, the optimal X-ray energy in imaging depends on the material composition and the subject size. Among the parameters related to the X-ray energy, we can arbitrarily change only the tube voltage. For years, the tube voltage has often been set at 120 kVp. However, since about 2000, there has been an increasing interest in reducing radiation dose, and it has led to the publication of various reports on low tube voltage. Furthermore, with the spread of dual-energy CT, virtual monochromatic X-ray images are widely used since the contrast can be adjusted by selecting the optional energy. Therefore, because of the renewed interest in X-ray energy in CT imaging, the issue of energy and imaging needs to be summarized. In this article, we describe the basics of physical characteristics of X-ray attenuation with materials and its influence on the process of CT imaging. Moreover, the relationship between X-ray energy and CT imaging is discussed for clinical applications.


Asunto(s)
Interpretación de Imagen Radiográfica Asistida por Computador , Tomografía Computarizada por Rayos X , Fantasmas de Imagen , Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Rayos X
5.
Phys Med ; 60: 100-110, 2019 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-31000069

RESUMEN

Noise reduction features of iterative reconstruction (IR) methods in computed tomography might accompany the sacrifice of the longitudinal resolution, or slice sensitivity profile (SSP), at low contrast-to-noise ratio (CNR) conditions. To assess the benefit of IR methods correctly, the difference of SSP between IR methods and filtered-backprojection (FBP) must be taken into account. Therefore, SSP measurement under low-CNR conditions is necessary. Although edge methods are predominantly used, their performance under low-CNR conditions appears to be not fully established. We developed a method that is compatible with extremely low-CNR conditions. Thin plastic disk-shaped sheets embedded in acrylic resin were used as low-contrast test objects. The lowest peak contrast used was approximately 17 [HU]. We assessed the performance of our method by using FBP images. We identified a source of measurement instability aside from noise: the measured thin-slice SSP is dependent on the orbital phase of helical scan, presumably because of cone-beam artifacts. This impediment to high accuracy is manageable using phase-controlled scans. We confirmed that table position repeatability is much better than the value of the specifications, and therefore the ensemble-averaged images of multiple scans can be used for SSP measurement. Accurate measurement of SSP under extremely low-CNR conditions is possible, even when the test object is visually indiscernible from the noisy background. Low-contrast SSP behavior is elucidated for IR methods (AIDR-3D, FIRST, and AiSR-V) by using this measurement method.


Asunto(s)
Tomografía Computarizada por Rayos X/métodos , Artefactos , Fantasmas de Imagen , Plásticos , Reproducibilidad de los Resultados , Tomografía Computarizada por Rayos X/instrumentación
6.
Radiol Phys Technol ; 11(2): 125-137, 2018 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-29476396

RESUMEN

Edge methods are predominantly used for modulation transfer function (MTF) measurements in computed tomography (CT) images reconstructed using iterative methods. However, edge methods employ a relatively large and distinct test object, which is intended to simulate relatively large and distinct clinical organs. If one wants to assess the image quality of a small low-contrast object that is visually indistinct against a noisy background, a small and indistinct test object is desired. Another concern is that information related to the signal amount is discarded during MTF measurements. Choosing a weak impulse as the ultimately small test object, we have developed a tilted-wire method, which is a type of point spread function (PSF) method compatible with extremely low contrast-to-noise ratio (CNR) conditions. The signal amount is measured as the PSF volume. We used two commercial CT systems to evaluate the measurement accuracy of the tilted-wire method. When ensemble-averaged images are used, one can measure the MTF even when the wire is indiscernible from noise. The measurement error under such conditions is a few percent for both the MTF and signal amount. We also applied the tilted-wire method to two hybrid iterative reconstruction methods, namely AIDR-3D and ASiR. The results show that the MTF of ASiR is completely CNR-dependent, but that of AIDR-3D is noise-dependent. The signal amount obtained with ASiR is unchanged from that obtained through filtered back-projection (FBP). The signal amount obtained with AIDR-3D is less than that obtained through FBP, depending on the noise level.


Asunto(s)
Relación Señal-Ruido , Tomografía Computarizada por Rayos X/métodos , Fantasmas de Imagen , Dosis de Radiación , Reproducibilidad de los Resultados , Tomografía Computarizada por Rayos X/instrumentación
7.
Radiol Phys Technol ; 8(2): 178-92, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-25577233

RESUMEN

X-ray CT projection data often include components with frequencies that are markedly higher than the pixel Nyquist frequency f PN, which is determined by the pixel size. Noise components higher than f PN are folded back into a region lower than f PN through the backprojection process, thereby creating aliased noise. With clinical CT scanners, we evaluated the aliased noise using an aliasing prevention measure, band-limiting processing (BLP), which suppresses frequency components higher than f PN in the projection data. Indices we used to evaluate improvement by BLP were the noise power spectrum (NPS), modulation transfer function (MTF), signal-to-noise-ratio (SNR) spectrum, matched filter SNR (MF SNR), and two-alternative forced-choice (2-AFC) test. With BLP, the NPS was decreased not only beyond f PN, but also within f PN. The same level of MTF was maintained as that without BLP within f PN. No remarkable reduction in spatial resolution was observed. The SNR spectrum and the MF SNR of the BLP image nearly agreed with those of an ideal state without aliased noise. A notable improvement in the visuoperceptual image quality by BLP was recognized with a reconstruction field of view (FOV) of more than 45 cm. We then applied BLP to clinical data and confirmed that significant aliased noise of a large FOV image was removed without notable side effects. The results showed that at least some CTs suffering from aliased noise can be improved by proper band-limiting.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Relación Señal-Ruido , Tomografía Computarizada por Rayos X/métodos , Humanos , Pelvis/diagnóstico por imagen , Fantasmas de Imagen
8.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 64(4): 434-41, 2008 Apr 20.
Artículo en Japonés | MEDLINE | ID: mdl-18451600

RESUMEN

As a result of the development of multi-slice CT, diagnoses based on three-dimensional reconstruction images and multi-planar reconstruction have spread. For these applications, which require high z-resolution, thin slice imaging is essential. However, because z-resolution is always based on a trade-off with image noise, thin slice imaging is necessarily accompanied by an increase in noise level. To improve the quality of thin slice images, a non-linear adaptive smoothing filter has been developed, and is being widely applied to clinical use. We developed a digital bar pattern phantom for the purpose of evaluating the effect of this filter and attempted evaluation from an addition image of the bar pattern phantom and the image of the water phantom. The effect of this filter was changed in a complex manner by the contrast and spatial frequency of the original image. We have confirmed the reduced effect of image noise in the low frequency component of the image, but decreased contrast or increased quantity of noise in the image of the high frequency component. This result represents the effect of change in the adaptation of this filter. The digital phantom was useful for this evaluation, but to understand the total effect of filtering, much improvement of the shape of the digital phantom is required.


Asunto(s)
Filtración/instrumentación , Fantasmas de Imagen , Intensificación de Imagen Radiográfica/instrumentación , Tomografía Computarizada Espiral/instrumentación , Intensificación de Imagen Radiográfica/métodos , Tomografía Computarizada Espiral/métodos