Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Orthod Craniofac Res ; 2024 Jun 11.
Artículo en Inglés | MEDLINE | ID: mdl-38859724

RESUMEN

BACKGROUND: To compare and investigate the effects of intraoral ageing on the thickness of one group of directly printed and two groups of thermoformed aligners on the labial surface of maxillary central incisors. MATERIALS AND METHODS: Six groups (12 samples per group) were included in this prospective in vivo experiment. Groups DP-Clin, INV-Clin and CA-Clin consisted of directly printed (Tera Harz TC-85 DAC resin), thermoformed (Invisalign, PU based polymer) and in house thermoformed (CA-Pro, PET-G based polymer) aligners, retrieved after 1 week of intraoral service. Groups DP-Ctr, INV-Ctr and CA-Ctr included unused aligners samples. Thickness measurements were conducted using confocal laser scanning microscopy (CLSM). Data that underwent log-10 transformation was analysed by multiple linear regression analysis (p < .05). RESULTS: Statistically significant differences were found between the materials in both Clin and Ctr categories (p < .001). Group DP had the highest thickness among the groups and the least thickness was observed in the CA group (p < .001). However, intraoral ageing did not significantly affect the aligner thickness of any groups. CONCLUSIONS: Both thermoforming and direct printing of clear aligners led to thickness deviations in terms of increase for printed aligners and decrease for thermoformed aligners. Intraoral ageing did not affect the aligner thickness in any of the groups.

2.
Am J Orthod Dentofacial Orthop ; 165(1): 73-79, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37665312

RESUMEN

INTRODUCTION: Direct printing of clear aligners could be the next paradigm shift in modern orthodontics and can potentially overcome the limitation of the indirect production method. This study investigated the effects of 1 week of intraoral usage on the surface roughness parameters of directly printed aligners (DPAs) and commercially produced Invisalign aligners compared with their unused control counterparts using confocal laser scanning microscopy. METHODS: The study consisted of 4 groups with 34 samples per group. Unused control aligners were allocated to the control groups (DP-Ctr and INV-Ctr). Sixty-eight patients undergoing clear aligner therapy were allocated to group DP-Clin (patients in therapy using DPAs made from TC-85 DAC resin) and group INV-Clin (patients provided with Invisalign aligners). After 1 week of intraoral usage, the aligners were retrieved from the patients in groups DP-Clin and INV-Clin. Samples were made from the buccal surface of the maxillary right central incisor of each aligner and underwent surface roughness and porosity measuring using confocal laser scanning microscopy. The arithmetic mean deviation of the profile, root mean square deviation, maximum peak height, maximum valley depth, maximum height difference among the highest peak and deepest valley, void volume, and void count were measured. Descriptive analysis and median (quantile) regression models were used for data analysis of this experiment. RESULTS: One week of intraoral usage significantly increased the surface roughness and porosity of DPAs. In contrast, a significant reduction in the surface roughness and porosity parameters of Invisalign aligners was recorded after intraoral service. CONCLUSIONS: This study suggests an increase in the surface roughness and surface porosity of DPAs following 1 week of intraoral usage, which might lead to an increase in bacterial adhesion and biofilm formation in these aligners.


Asunto(s)
Aparatos Ortodóncicos Removibles , Humanos , Porosidad , Estudios Prospectivos
3.
Eur J Orthod ; 46(1)2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-37936263

RESUMEN

OBJECTIVE: The objective of this study was to examine the impact of intraoral aging on the mechanical properties of directly printed aligners (DPA) compared to thermoformed aligners (TA). MATERIALS AND METHODS: This prospective in vivo experiment included three types of aligners: DPAs (group DP) fabricated from Tera Harz TC-85 DAC resin (Graphy, Korea), TA (group INV) made from a polyurethane-based polymer (Align Technology, Inc., CA, USA), and TA (group DUR) made from polyethylene glycol terephthalate based polymer (Scheu-Dental, Germany). Each group was categorized into retrieved (Clin) and unused aligners (Ctr). Thirty patients (10 per group) wore the aligners for 7 days, thereby generating the retrieved samples. Thirty unused aligners were employed as control samples. The following mechanical properties were determined: Martens Hardness (HM), indentation modulus (EIT), elastic index (ηIT), and indentation relaxation (RIT). Intergroup comparisons were conducted using ANOVA/Kruskal-Wallis test. Comparisons between retrieved and control samples were done using Wilcoxon-Mann-Whitney-U/Student's t-test/Welch's test. RESULTS: Statistically significant differences between the groups were found for both control and used samples (P < .001). Pairwise comparisons also revealed significant differences between the samples. The mechanical properties did not differ significantly between unused and retrieved INV- and DUR-aligners, whereas for DP-aligners significant differences for ηIT and RIT were found following intraoral service (P-values .012 and .002, respectively). CONCLUSIONS: Group DUR showed generally more favorable mechanical properties compared to DP and INV. The much higher RIT and EIT in DP aligners suggest their higher rigidity and force decay, which could compromise their clinical efficacy.


Asunto(s)
Fenómenos Mecánicos , Poliuretanos , Humanos , Estudios Prospectivos , Dureza , Polietilenglicoles , Ensayo de Materiales
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA