Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Appl Radiat Isot ; 193: 110645, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36642038

RESUMEN

Proton therapy is an external radiotherapy using proton beams with energies between 70 and 230 MeV to treat some type of tumours with outstanding benefits, due to its energy transfer plot. There is a growing demand of facilities taking up small spaces and Compact Proton Therapy Centers (CPTC), with one or two treatment rooms, supposing the technical response of manufacturers to this request. A large amount of stray radiation is yielded in the interaction of proton beam used in therapy, neutrons mainly, hence, optimal design of shielding and verifications must be carried out in commissioning phases. Currently, almost 50 proton centers are under construction and start up in several countries, including ten in Spain. In the present work the effectiveness of shielding in two CPTC was verified with the Monte Carlo code MCNP6 by calculating the ambient dose equivalent, H*(10) due to secondary neutrons, outside the enclosures and walls of the center. The facilities modelled were the two centers currently operating in Spain, the first, since December 2019, with a superconductor synchrocyclotron, and the second, since March 2020, with a compact synchrotron. The geometry and materials are based on dimensions proposed a priori by the vendors, therefore, the paper is focused on check the suitability of the materials and thickness of the walls of the centers. Several models of the radiation sources were simulated, starting from a conservative assumptions, followed by more realistic scenarios. In all cases, the results reached for the ambient dose equivalent, H*(10), were below 1 mSv/year, which is the legal limit considered for the public in international references. Finally, considering that the recent ICRU Report 95 proposes changes in the operational quantities, the dose outside shieldingt has been evaluated in terms of the new next area surveillance quantity, H*, known as ambient dose, in the process of implementation.

2.
Appl Radiat Isot ; 169: 109279, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33451908

RESUMEN

Proton therapy (PT) is an external radiotherapy using proton beams with energies between 70 and 230 MeV to treat some type of tumours with outstanding benefits, due to its energy transfer plot. There is a growing demand of facilities taking up small spaces and Compact Proton Therapy Centers (CPTC), with one or two treatment rooms, supposing the technical response of manufacturers to this request. A large amount of stray radiation is produced in the interaction of protons used in therapy, neutrons mainly, hence, optimal design of shielding and verifications must be carried out in commissioning stages. Currently, almost 50 CPTC are under construction and start up in many countries, including several in Spain. In the present work, the effectiveness of shielding in a CPTC was verified with the Monte Carlo code MCNP6 by calculating the ambient dose equivalent, H*(10) due to secondary neutrons, outside the enclosures and walls of the center. The facility modelled was similar to one planned to start operating in 2019 in Spain, a CPTC, made up of a superconducting synchrocyclotron and one treatment room, with a configuration standard, shielding and width of barriers based on dimensions proposed a priori by the vendor. Therefore, the paper is focused in check the suitability of the materials and thickness of the walls of the center and develop the assessment of enclosures. Several models of the radiation sources and type of concrete in walls were simulated, starting from a conservative assumptions, followed by more realistic models. In all cases, the results were below 1 mSv/year, which is the international legal limit considered for the general public. This work is part of the project Contributions to Shielding and Dosimetry of Neutrons in Compact Proton Therapy Centers (CPTC).


Asunto(s)
Neutrones , Terapia de Protones , Protección Radiológica , Dosificación Radioterapéutica , Humanos , Método de Montecarlo , Incertidumbre
3.
J Environ Radioact ; 175-176: 105-114, 2017 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-28505478

RESUMEN

Exposure to radiation is a potential hazard to humans and the environment. The Fukushima accident reminded the world of the importance of a reliable risk management system that incorporates the dose received from radiation exposures. The dose to humans from exposure to radiation can be quantified using a well-defined system; its environmental equivalent, however, is still in a developmental state. Additionally, the results of several papers published over the last decade have been criticized because of poor dosimetry. Therefore, a workshop on environmental dosimetry was organized by the STAR (Strategy for Allied Radioecology) Network of Excellence to review the state of the art in environmental dosimetry and prioritize areas of methodological and guidance development. Herein, we report the key findings from that international workshop, summarise parameters that affect the dose animals and plants receive when exposed to radiation, and identify further research needs. Current dosimetry practices for determining environmental protection are based on simple screening dose assessments using knowledge of fundamental radiation physics, source-target geometry relationships, the influence of organism shape and size, and knowledge of how radionuclide distributions in the body and in the soil profile alter dose. In screening model calculations that estimate whole-body dose to biota the shapes of organisms are simply represented as ellipsoids, while recently developed complex voxel phantom models allow organ-specific dose estimates. We identified several research and guidance development priorities for dosimetry. For external exposures, the uncertainty in dose estimates due to spatially heterogeneous distributions of radionuclide contamination is currently being evaluated. Guidance is needed on the level of dosimetry that is required when screening benchmarks are exceeded and how to report exposure in dose-effect studies, including quantification of uncertainties. Further research is needed to establish whether and how dosimetry should account for differences in tissue physiology, organism life stages, seasonal variability (in ecology, physiology and radiation field), species life span, and the proportion of a population that is actually exposed. We contend that, although major advances have recently been made in environmental radiation protection, substantive improvements are required to reduce uncertainties and increase the reliability of environmental dosimetry.


Asunto(s)
Exposición a la Radiación/estadística & datos numéricos , Monitoreo de Radiación/métodos , Animales , Humanos , Dosis de Radiación , Protección Radiológica , Radiometría , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA