Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 127
Filtrar
1.
Arq Bras Oftalmol ; 87(2): e20220319, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38451683

RESUMEN

PURPOSE: To assess Meibomian gland dysfunction using meibography in patients with xeroderma pigmentosum and correlate with ocular surface changes. METHODS: This cross-sectional study evaluated patients with xeroderma pigmentosum. All patients underwent a comprehensive and standardized interview. The best-corrected visual acuity of each eye was determined. Detailed ophthalmic examination was conducted, including biomicroscopy examination of the ocular surface, Schirmer test type I, and meibography, and fundus examination was also performed when possible. Meibomian gland dysfunction was assessed by non-contact meibography using Oculus Keratograph® 5M (OCULUS Inc., Arlington, WA, USA). Saliva samples were collected using the Oragene DNA Self-collection kit (DNA Genotek Inc., Ottawa, Canada), and DNA was extracted as recommended by the manufacturer. Factors associated with abnormal meiboscores were assessed using generalized estimating equation models. RESULTS: A total of 42 participants were enrolled, and 27 patients underwent meibography. The meiboscore was abnormal in the upper eyelid in 8 (29.6%) patients and in the lower eyelid in 17 (62.9%). The likelihood of having abnormal meiboscores in the lower eyelid was 16.3 times greater than that in the upper eyelid. In the final multivariate model, age (p=0.001), mutation profile (p=0.006), and presence of ocular surface malignant tumor (OSMT) (p=0.014) remained significant for abnormal meiboscores. For a 1-year increase in age, the likelihood of abnormal meiboscores increased by 12%. Eyes with OSMT were 58.8 times more likely to have abnormal meiboscores than eyes without ocular surface malignant tumor. CONCLUSION: In the final model, age, xeroderma pigmentosum profile, previous cancer, and clinical alterations on the eyelid correlated with a meiboscore of ≥2. Meibomian gland dysfunction was common in patients with xeroderma pigmentosum, mainly in the lower eyelid. The severity of Meibomian gland dysfunction increases with age and is associated with severe eyelid changes.


Asunto(s)
Neoplasias del Ojo , Disfunción de la Glándula de Meibomio , Xerodermia Pigmentosa , Humanos , Estudios Transversales , Xerodermia Pigmentosa/complicaciones , Xerodermia Pigmentosa/diagnóstico por imagen , Párpados , ADN
2.
Arq. bras. oftalmol ; Arq. bras. oftalmol;87(2): e2022, 2024. tab, graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1533785

RESUMEN

ABSTRACT Purpose: To assess Meibomian gland dysfunction using meibography in patients with xeroderma pigmentosum and correlate with ocular surface changes. Methods: This cross-sectional study evaluated patients with xeroderma pigmentosum. All patients underwent a comprehensive and standardized interview. The best-corrected visual acuity of each eye was determined. Detailed ophthalmic examination was conducted, including biomicroscopy examination of the ocular surface, Schirmer test type I, and meibography, and fundus examination was also performed when possible. Meibomian gland dysfunction was assessed by non-contact meibography using Oculus Keratograph® 5M (OCULUS Inc., Arlington, WA, USA). Saliva samples were collected using the Oragene DNA Self-collection kit (DNA Genotek Inc., Ottawa, Canada), and DNA was extracted as recommended by the manufacturer. Factors associated with abnormal meiboscores were assessed using generalized estimating equation models. Results: A total of 42 participants were enrolled, and 27 patients underwent meibography. The meiboscore was abnormal in the upper eyelid in 8 (29.6%) patients and in the lower eyelid in 17 (62.9%). The likelihood of having abnormal meiboscores in the lower eyelid was 16.3 times greater than that in the upper eyelid. In the final multivariate model, age (p=0.001), mutation profile (p=0.006), and presence of ocular surface malignant tumor (OSMT) (p=0.014) remained significant for abnormal meiboscores. For a 1-year increase in age, the likelihood of abnormal meiboscores increased by 12%. Eyes with OSMT were 58.8 times more likely to have abnormal meiboscores than eyes without ocular surface malignant tumor. Conclusion: In the final model, age, xeroderma pigmentosum profile, previous cancer, and clinical alterations on the eyelid correlated with a meiboscore of ≥2. Meibomian gland dysfunction was common in patients with xeroderma pigmentosum, mainly in the lower eyelid. The severity of Meibomian gland dysfunction increases with age and is associated with severe eyelid changes.

3.
Arq. bras. oftalmol ; Arq. bras. oftalmol;87(4): e2022, 2024. tab, graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1520232

RESUMEN

ABSTRACT Purpose: To compare the differences between the apparent and actual chord μ. Methods: In this prospective, comparative, non-randomized, and non-interventional study, imaging examinations using Pentacam and the HD Analyzer were performed in the same room under the same scotopic conditions. The inclusion criteria were patients aged 21-71 years, able to provide informed consent, myopia up to 4D, and anterior topographic astigmatism up to 1D. Patients using contact lenses, those with previous eye diseases or surgeries, corneal opacities, corneal tomographic changes, or suspected keratoconus were excluded. Results: Altogether, 116 eyes of 58 patients were analyzed. The patients' mean age was 30.69 (±7.85) years. In the correlation analyses, Pearson's correlation coefficient of 0.647 indicates a moderate positive linear relationship between apparent and actual chord μ. The mean actual and apparent chord μ were 226.21 ± 128.53 and 278.66 ± 123.90 μm, respectively, with a mean difference of 52.45 μm (p=0.01). The analysis of mean pupillary diameter resulted in 5.76 mm using the HD Analyzer and 3.31 mm using the Pentacam. Conclusions: We found a correlation between the two measurement devices, and even though we found considerable differences, both can be used in daily practice. Given their differences, we should respect their peculiarities as well.


RESUMO Objetivo: Comparar as diferenças entre a chord aparente μ e o chord real μ. Métodos: Estudo prospectivo, comparativo, não randomizado e não intervencionista. Os exames de imagem (Pentacam e HD Analyzer) foram realizados na mesma sala e nas mesmas condições escotópicas. Os critérios de inclusão foram idade de 21 a 71 anos; compreensão do termo de consentimento; miopia até 4D e astigmatismo topográfico anterior até 1D. Os critérios de exclusão foram usuários de lentes de contato; pacientes com doenças oculares prévias ou cirurgias; opacidades da córnea; a presença de alterações tomográficas da córnea ou suspeita de ceratocone. Resultados: Em nosso estudo foram analisados 116 olhos de 58 pacientes. A média de idade foi de 30,69 anos (± 7,85). Análises de correlação foram desenvolvidas e o coeficiente de correlação de Pearson (0,647) indica uma relação linear positiva moderada entre as variáveis. A média do chord μ real foi 226,21 ± 128,53 μm e a média do chord μ média foi 278,66 ± 123,90 μm, com diferença média de 52,45 μm (p=0,01). A análise do diâmetro pupilar médio apresentou: 5,76mm no HD Analyzer e 3,31mm no Pentacam. Conclusões: Entendemos a existência de uma diferença significativa entre os métodos e assim a medida de ambos os dispositivos com base em princípios diferentes devemos respeitar suas peculiaridades. Como encontramos correlação entre as duas medidas, acreditamos que ambas podem ser utilizadas na prática diária.

4.
Arq Bras Oftalmol ; 2023 Mar 24.
Artículo en Inglés | MEDLINE | ID: mdl-36995814

RESUMEN

PURPOSE: To compare the differences between the apparent and actual chord µ. METHODS: In this prospective, comparative, non-randomized, and non-interventional study, imaging examinations using Pentacam and the HD Analyzer were performed in the same room under the same scotopic conditions. The inclusion criteria were patients aged 21-71 years, able to provide informed consent, myopia up to 4D, and anterior topographic astigmatism up to 1D. Patients using contact lenses, those with previous eye diseases or surgeries, corneal opacities, corneal tomographic changes, or suspected keratoconus were excluded. RESULTS: Altogether, 116 eyes of 58 patients were analyzed. The patients' mean age was 30.69 (±7.85) years. In the correlation analyses, Pearson's correlation coefficient of 0.647 indicates a moderate positive linear relationship between apparent and actual chord µ. The mean actual and apparent chord µ were 226.21 ± 128.53 and 278.66 ± 123.90 µm, respectively, with a mean difference of 52.45 µm (p=0.01). The analysis of mean pupillary diameter resulted in 5.76 mm using the HD Analyzer and 3.31 mm using the Pentacam. CONCLUSIONS: We found a correlation between the two measurement devices, and even though we found considerable differences, both can be used in daily practice. Given their differences, we should respect their peculiarities as well.

5.
Int J Mol Sci ; 24(3)2023 Feb 03.
Artículo en Inglés | MEDLINE | ID: mdl-36769303

RESUMEN

Cell injection therapy is emerging as an alternative to treat corneal endothelial dysfunction (CED) and to avoid corneal scarring due to bullous keratopathy. However, establishing a standardized culture procedure that provides appropriate cell yield while retaining functional features remains a challenge. Here, we describe a detailed framework obtained from in vitro culture of human corneal endothelial cells (HCECs) and comparative in vivo experimental models for CED treatment with a new cell tracking approach. Two digestion methods were compared regarding HCEC morphology and adhesion. The effect of Y-27632 (ROCKi) supplementation on final cell yield was also assessed. Cell adhesion efficacy with two cell delivery systems (superparamagnetic embedding and cell suspension) was evaluated in an ex vivo human cornea model and in an in vivo rabbit CED model. The injection of supplemented culture medium or balanced salt solution (BSS) was used for the positive and negative controls, respectively. HCEC isolation with collagenase resulted in better morphology and adhesion of cultured HCEC when compared to EDTA. Y-27632 supplementation resulted in a 2.6-fold increase in final cell yield compared to the control. Ex vivo and in vivo adhesion with both cell delivery systems was confirmed by cell tracker fluorescence detection. Corneal edema and opacity improved in both animal groups treated with cultured HCEC. The corneas in the control groups remained opaque. Both HCEC delivery systems seemed comparable as treatments for CED and for the prevention of corneal scarring.


Asunto(s)
Rastreo Celular , Endotelio Corneal , Animales , Humanos , Conejos , Células Endoteliales , Cicatriz/patología , Células Cultivadas
6.
Rev. bras. oftalmol ; 82: e0056, 2023. tab, graf
Artículo en Portugués | LILACS | ID: biblio-1521788

RESUMEN

RESUMO Objetivo Avaliar o perfil dos alunos concluintes, deficientes visuais e videntes do Instituto de Cegos Padre Chico entre os anos 2011 e 2020. Métodos Entre janeiro e março de 2021, foi realizada uma análise documental dos alunos concluintes entre os anos de 2011 e 2020. Foram coletados dados relacionados à situação social, educacional, socioeconômica e oftalmológica. Os dados foram tratados no programa Microsoft Excel 2013 da Microsoft e analisados no software livre Bioestat, versão 5.0. Resultados Foram coletados os dados de 110 concluintes cegos, com baixa visão e videntes. Mais de 90% dos alunos declararam rendimento familiar equivalente a um salário-mínimo e meio. Do total da amostra, 52 alunos eram cegos; 38 tinham baixa visão, e 20 eram videntes. Dentre as 36 patologias identificadas entre os alunos, 57,78% levaram à cegueira e 42,22%, à baixa visão. Em alunos cegos, as patologias mais frequentes foram glaucoma congênito (32,69%) e amaurose congênita de Leber (11,53%); em alunos com baixa visão, foram glaucoma congênito e distrofias de retina (ambas em 10,53% da amostra). Conclusão É de suma importância a avaliação da saúde ocular para que o professor realize de forma mais rápida as práticas de ensino e alcance resultados satisfatórios na alfabetização de crianças com deficiência visual.


ABSTRACT Objective To evaluate the profile of visually impaired and sighted students at the Instituto de Cegos Padre Chico (ICPC) between 2011 and 2020. Methods Between January and March 2021, a document analysis of the students who completed the undergraduate course between 2011 and 2020. Data related to social, educational, socioeconomic, and ophthalmological situation were collected. The data were treated in Microsoft Excel 2013 and analyzed in the free software Bioestat, version 5.0. Results Retrospective data were collected from 110 blind, low-vision and sighted students who were graduating. More than 90% of the students declared family income equivalent to one and a half minimum wages. Of the total sample, 52 students were blind; 38 had low vision, and 20 were sighted students. Among the 36 pathologies identified among the students, 57.78% led to blindness, and 42.22%, to low vision. In blind students, the most frequent diagnosis was congenital glaucoma (32.69%) and Leber congenital amaurosis (11.53%); in low vision students, congenital glaucoma and retinal dystrophies (both in 11.53% of the population of this study). Conclusion The evaluation of the eye health is of vital importance for the teacher to perform teaching practices faster and achieve satisfactory results in the literacy of visually impaired children.


Asunto(s)
Humanos , Masculino , Femenino , Adolescente , Adulto , Ceguera , Baja Visión , Personas con Daño Visual , Dispositivos de Autoayuda , Factores Socioeconómicos , Estudiantes/estadística & datos numéricos , Trastornos de la Visión/clasificación , Estudios Retrospectivos , Oftalmopatías/epidemiología , Educación de Personas con Discapacidad Visual
7.
Transl Vis Sci Technol ; 11(8): 14, 2022 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-35976657

RESUMEN

Purpose: To evaluate the surgical technique, clinical performance, and biocompatibility of a novel keratoprosthesis (KPro) named KPro of Brazil (KoBra) in an alkali-burned rabbit model. Methods: Two-piece three-dimensional-printed titanium powder and polymethyl methacrylate KPros were implanted into 14 alkali-burned corneas of 14 rabbits using an autologous full-thickness corneal graft as the KPro carrier. Rabbits were examined weekly for 12 months to evaluate retention and postoperative complications. Anterior segment optical coherence tomography (AS-OCT) and scanning electron microscopy (SEM) were performed at the end of the experiment to evaluate the relationship between the KoBra and the carrier graft. Results: All surgeries were performed without intraoperative complications, and the immediate postoperative period was uneventful. In 12 eyes (85.7%), the implanted KPros integrated into the operated eyes and maintained clear optics without extrusion or further complications over 12 months. Two eyes presented late postoperative complications that progressed to KPro extrusion: one had a presumed infectious keratitis, and the other had sterile stromal necrosis. AS-OCT demonstrated the correct relationship of the device and carrier graft in all remaining animals at the final follow-up. SEM findings indicate the integration of the porous structure of the back plate into the surrounding tissue. Conclusions: Clinical evaluations, AS-OCT, and SEM findings indicate good biointegr-ation of the implanted device into the corneal carrier graft. KoBra has the advantage of using recipients' own corneas as the prosthesis supporter, and its surgical procedure is relatively simple and safe. Translational Relevance: Titanium three-dimensional-printed technology used in an animal limbal stem-cell deficiency model holds great promise for the treatment of corneal blindness in humans.


Asunto(s)
Quemaduras Químicas , Enfermedades de la Córnea , Lagomorpha , Álcalis , Animales , Quemaduras Químicas/cirugía , Córnea/cirugía , Enfermedades de la Córnea/cirugía , Humanos , Complicaciones Posoperatorias , Polvos , Impresión Tridimensional , Prótesis e Implantes , Conejos , Titanio
8.
Arq. bras. oftalmol ; Arq. bras. oftalmol;84(6): 582-586, Nov.-Dec. 2021. tab, graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1350069

RESUMEN

ABSTRACT Purpose: This quality and reliability study aimed to identify the mass variability of multidose eyedrops and to verify the existence of a reference pattern for the drop volume of eyedrops using standard lubricant eyedrops available on the Brazilian market. Methods: Five brands of lubricant eyedrops were evaluated. An ideal standard 20 µL drop of eyedrops from each manufacturer was captured using an adjustable micropipette. The eyedrop bottles were randomly selected, and five measurements of the samples' masses were collected using calibrated precision scales. Results: The mass of the 20 µL samples varied significantly (p<0.001) among the different manufacturers. However, among eyedrops of the same brand, mass variation was not statistically different. The global mean mass of all weighed drops was 18.24 mg, and non-uniformity was identified across all eyedrop brands. Conclusion: Significant variations in the drop masses of common lubricant eyedrops were identified using standard laboratory equipment. Heterogeneity in the drop volume of standard eyedrop medications suggest that potential dosage discrepancies exist, possibly altering treatment efficacy. A pre-established reference measure may lead to the production of more appropriately sized eyedrops for use in human eyes.


RESUMO Objetivo: Este estudo de qualidade e confiabilidade teve como objetivo identificar a variabilidade da massa do volume da gota de colírios multidose e verificar a existência de um padrão de referência para o volume da gota dos colírios usando lágrimas artificiais do mercado brasileiro. Métodos: Cinco marcas de colírios lubrificantes foram avaliadas quanto ao volume da gota. Uma gota padrão ideal de 20 µL de cada fabricante foi coletada usando uma micropipeta ajustável. Os frascos dos colírios foram selecionados aleatoriamente e cinco medidas das massas das amostras foram coletadas usando escalas de precisão calibradas. Resultados: A massa das amostras de 20 µL variou significativamente (p<0,001) entre os diferentes fabricantes. No entanto, entre os colírios da mesma marca, a variação da massa não foi estatisticamente diferente. A massa média global de todas as gotas pesadas foi de 18,24 mg e foi observada uma não-uniformidade entre todas as marcas de colírios. Conclusão: Identificou-se uma variação significativa nas massas do volume das gotas dos colírios lubrificantes, usando equipamento padrão de laboratório. A heterogeneidade no volume da gota dos colírios testados sugere a existência de discrepâncias potenciais em suas posologias, possivelmente alterando a eficácia do tratamento. Uma medida de referência pré-estabelecida pode levar à produção de colírios com gotas de tamanho mais apropriado para uso em olhos humanos.

9.
PLoS One ; 16(11): e0259399, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34762686

RESUMEN

PURPOSE: Dry eye is a common, complex, and multifactorial disease of the ocular surface and tear film that results in discomfort and visual disturbances. Prevalence rates vary and largely rely on studies involving older populations. This study sought to evaluate dry eye among a sample of young students in Brazil. METHODS: Cross-sectional survey included 2,140 students using 2 self-applicable questionnaires of dry eye symptoms: the Ocular Surface Disease Index (OSDI) and the Women's Health Study (WHS) questionnaire and a list of risk factors associated with dry eye. Participants with dry eye symptoms underwent a clinical evaluation. RESULTS: Participants were 23.4±5.2 years of age, 56.1% female and 43.9% male, 34.4% had an OSDI score greater than 22, and 23.5% had dry eye according to the WHS. Dry eye frequency differed consistently between the sexes: 42.6% women and 24.0% men based on the OSDI, and 27.1% women and 18.5% men based on the WHS. Univariate and multivariate analyses demonstrated that female sex, contact lens wear, the screen use for more than 6 hours per day, less than 6 hours of sleep a night, and certain medications were relevant related risk factors for dry eye. Despite symptoms, clinical evaluations demonstrated mild signs of dry eye. CONCLUSIONS: Dry eye symptoms were found to be a prevalent condition among Brazilian undergraduate students. Compared to the rates of dry eye among the general Brazilian population over 40 years of age, students present at higher dry eye symptoms rates and distinct odds for related risk factors were identified.


Asunto(s)
Síndromes de Ojo Seco/diagnóstico , Estudiantes/estadística & datos numéricos , Adolescente , Adulto , Brasil/epidemiología , Lentes de Contacto , Estudios Transversales , Síndromes de Ojo Seco/epidemiología , Síndromes de Ojo Seco/patología , Femenino , Humanos , Masculino , Prevalencia , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores Sexuales , Sueño , Encuestas y Cuestionarios , Adulto Joven
10.
Arq Bras Oftalmol ; 84(6): 582-586, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34431879

RESUMEN

PURPOSE: This quality and reliability study aimed to identify the mass variability of multidose eyedrops and to verify the existence of a reference pattern for the drop volume of eyedrops using standard lubricant eyedrops available on the Brazilian market. METHODS: Five brands of lubricant eyedrops were evaluated. An ideal standard 20 µL drop of eyedrops from each manufacturer was captured using an adjustable micropipette. The eyedrop bottles were randomly selected, and five measurements of the samples' masses were collected using calibrated precision scales. RESULTS: The mass of the 20 µL samples varied significantly (p<0.001) among the different manufacturers. However, among eyedrops of the same brand, mass variation was not statistically different. The global mean mass of all weighed drops was 18.24 mg, and non-uniformity was identified across all eyedrop brands. CONCLUSION: Significant variations in the drop masses of common lubricant eyedrops were identified using standard laboratory equipment. Heterogeneity in the drop volume of standard eyedrop medications suggest that potential dosage discrepancies exist, possibly altering treatment efficacy. A pre-established reference measure may lead to the production of more appropriately sized eyedrops for use in human eyes.


Asunto(s)
Soluciones Oftálmicas , Brasil , Humanos , Reproducibilidad de los Resultados
11.
Front Med (Lausanne) ; 8: 649369, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34222274

RESUMEN

Stevens-Johnson syndrome (SJS) and toxic epidermal necrolysis (TEN) are acute and potentially fatal inflammatory vesiculobullous reactions that affect the skin and mucous membranes, and which are most often triggered by particular medications and infections. In Brazil, the drugs most frequently associated with TEN and SJS include cold medicine such as dipyrone and NSAIDs, followed by carbamazepine, phenobarbital, penicillin, and allopurinol. Genetic variations have been found to increase the risk of SJS/TEN in response to triggering factors such as medications. The most closely associated genes found in Brazilian cold-medicine-related SJS/TEN patients with severe ocular complications are HLA-A*66:01 in those of mixed African and European ancestry and HLA-B*44:03 and HLA-C*12:03 in those of solely European ancestry. Our classification system for grading ocular surface complication severity in SJS/TEN patients revealed the most severe complications to be limbal stem cell deficiency and dry eye. Changes to the conjunctival flora have also been observed in SJS/TEN patients. Our group identified bacterial colonization in 95% of the eyes (55.5% of which were gram-positive cocci, 25.5% of which were gram-negative bacilli, and 19% of which were gram-positive bacilli). Several new treatment options in the acute and chronic ocular management of the SJS/TEN patients have been described. This article highlights some Brazilian institutions' contributions to ocular surface care in both the acute phase (including the use of amniotic membrane transplantation) and the chronic phase (such as eyelid margin and fornix reconstruction, minor salivary gland transplantation, amniotic membrane and limbal transplantation, scleral contact lenses, anti-angiogenic eyedrops for corneal neovascularization, ex-vivo cultivated limbal epithelium transplantation, conjunctival-limbal autografting, oral mucosa transplantation, and keratoprosthesis).

12.
Eur J Ophthalmol ; 31(6): 3505-3510, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34058904

RESUMEN

OBJECTIVE: Evaluation of central corneal densitometry changes following Ferrara corneal ring segment implantation in patients with keratoconus, especially the correlation between corneal densitometry and keratometry. METHODS: Retrospective, non-comparative, interventional study based on the review of medical records of patients diagnosed with keratoconus who underwent Ferrara corneal ring segment implantation. Pre and post-operative corneal densitometry measurements obtained with Pentacam HR (Oculus, Wetzlar, Germany) were analyzed. The follow-up time was 3 months, and data comparison was made, using specific statistical analysis, with the data of 3 months postoperatively. RESULTS: The study sample consisted of 43 eyes of 36 patients. The mean corrected visual acuity improved from 0.82 LogMAR preoperatively (SD ± 0.33) to 0.19 LogMAR (SD ± 0.13) postoperatively. The mean spherical equivalent varied from -4.63 (SD ± 3.94) preoperatively to -2.16 (SD ± 2.63) postoperatively. Asphericity varied from -0.69 (SD ± 0.32) preoperatively to -0.27 (SD ± 0.31) postoperatively. The mean maximum K was 54.01D (SD ± 3.38) preoperatively and 51.50D (SD ± 2.90) postoperatively. The mean anterior densitometric value was 18.26 (SD ± 2.03) preoperatively and 17.66 (SD ± 1.84) postoperatively. CONCLUSION: Corneal densitometry is an interesting technology that should be studied in keratoconus patients. Our results suggest that the corneal densitometry in the cornea's anterior layer reduces after ICRS implantation and correlates with corneal keratometry. Further studies should be performed to increase the knowledge in this field.


Asunto(s)
Queratocono , Córnea/diagnóstico por imagen , Sustancia Propia/diagnóstico por imagen , Sustancia Propia/cirugía , Topografía de la Córnea , Densitometría , Humanos , Queratocono/cirugía , Prótesis e Implantes , Implantación de Prótesis , Refracción Ocular , Estudios Retrospectivos , Agudeza Visual
13.
Eur J Ophthalmol ; 31(3): 1458-1462, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-33111555

RESUMEN

PURPOSE: To report a case series of pterygium surgery with conjunctival autograft fixation using bipolar electrocautery. DESIGN: A noncomparative, retrospective, interventional case series of pterygium surgery with follow-up longer than 12 months to assess recurrence and other complication rates. PARTICIPANTS: Fifty-six eyes of 37 patients were treated between April 2011 and January 2018, either for primary (n = 53 cases) or recurrent (n = 3 cases) pterygia. INTERVENTION: After pterygium excision, free conjunctival grafts from the inferior bulbar conjunctiva of the same eye were harvested and fixated with the use of bipolar electrocautery. MAIN OUTCOME MEASURE: Recurrence of the pterygium and complications. RESULTS: The mean follow-up was 41 months (range 12 to 81 months). There were no intraoperative complications. Recurrence of the lesion was seen in three eyes (5.36%). There were no other postoperative complications such as graft detachment, or formation of dellen or granulomas. CONCLUSION: Conjunctival autograft fixation using bipolar electrocautery seems to be a fast, costly and safe procedure that can be applied in most cases of pterygium surgery.


Asunto(s)
Conjuntiva , Pterigion , Autoinjertos , Electrocoagulación , Estudios de Seguimiento , Humanos , Complicaciones Posoperatorias , Pterigion/cirugía , Recurrencia , Estudios Retrospectivos , Trasplante Autólogo , Resultado del Tratamiento
15.
Transl Vis Sci Technol ; 9(7): 7, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-32832214

RESUMEN

Purpose: To evaluate the impact of instillation angle and nozzle tip geometry on cross-contamination risk of multidose ocular solution bottles. Methods: Pseudomonas aeruginosa solution was passed exclusively on the outside of the nozzle to simulate contamination on the exterior of topical agents. Three drops were administered from angles of 90° and 45° from bottles with either a round or sharp tip geometry, and the cultures were examined for growth. Two-hundred sixteen cultures from nine lubricant eyedrop brands currently existing in the Brazilian market were assessed for bacterial growth. Results: After seven days, bacterial contamination was detected in 53.7% of cultures when drops were administered at 90° and in 70.4% of cultures at 45°. Eyedrops collected from a rounded nozzle tip and an instillation angle of 90° transmitted bacteria in 69.4% of cases, whereas those administered from a sharp tip transmitted bacteria in only 22.2% of cases (P = 0.001). At an instillation angle of 45°, contamination was identified in 83.3% of bottles with a rounded tip geometry and in only eight of 18 bottles (44.4%) from those with a sharp nozzle geometry (P = 0.005). Conclusions: Adjusting the instillation angle of eyedrop solutions to 90°, as well as using a nozzle geometry that prevents flow of the solution to the side of the bottle, significantly reduced contamination rates. Translational Relevance: Standardizing drop bottles and adjusting delivery angle shows promise in reducing contamination rates and may critically impact the quality of care for patients requiring topical therapeutic agents.


Asunto(s)
Contaminación de Medicamentos , Gotas Lubricantes para Ojos , Bacterias , Brasil , Humanos , Pseudomonas aeruginosa
16.
Cornea ; 38(7): 806-811, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-31033696

RESUMEN

PURPOSE: To describe the outcomes of Descemet membrane endothelial keratoplasty (DMEK) performed by cornea fellows during their initial learning curve. METHODS: This prospective study included the first consecutive series of 53 DMEK surgeries performed by 14 corneal fellows at Sorocaba's Ophthalmological Hospital. Best spectacle-corrected visual acuity, endothelial cell density (ECD), and complications were evaluated. RESULTS: Of the eyes without ocular comorbidities and with complete visual acuity measurements, 97% of 33 eyes achieved a best spectacle-corrected visual acuity of ≥20/40 in 6 months. The mean (SD) preoperative donor ECD was 2453 (361) cells/mm, and at 6 months postoperatively, the in vivo mean ECD (SD) was found to be 1300 (587) cells/mm, an average loss of 47%. Preparation of the DMEK graft by the cornea fellows was successful in all cases. There were 9 eyes (17%) that experienced partial graft detachment requiring rebubbling. A total of 3 eyes (5.7%) failed to clear the cornea, all of which were managed with successful secondary endothelial keratoplasty. None of the eyes experienced pupillary block. CONCLUSIONS: Establishing DMEK in a fellowship program was successful with the supervision of an experienced DMEK surgeon. Even without the facility of a prestripped DMEK graft by an eye bank and with no backup tissue, no surgery was canceled because of graft preparation failure. Good visual outcomes were achieved with satisfactory ECD at 6-month follow-up, with an acceptable complication rate. Even the 3 eyes that failed to clear the cornea evolved well after secondary endothelial keratoplasty by the cornea fellows.


Asunto(s)
Enfermedades de la Córnea/cirugía , Queratoplastia Endotelial de la Lámina Limitante Posterior , Endotelio Corneal/trasplante , Adulto , Anciano , Anciano de 80 o más Años , Pérdida de Celulas Endoteliales de la Córnea , Lámina Limitante Posterior/cirugía , Queratoplastia Endotelial de la Lámina Limitante Posterior/educación , Becas , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Agudeza Visual
17.
Arq. bras. oftalmol ; Arq. bras. oftalmol;82(1): 32-37, Jan.-Feb. 2019. graf
Artículo en Inglés | LILACS | ID: biblio-973879

RESUMEN

ABSTRACT Purpose: To evaluate the ability of human immature dental pulp stem cells, which are mesenchymal stem cells of neural crest origin, to differentiate into the corneal epithelium for purposes of corneal transplantation and tissue engineering when cultured on de-epithelized amniotic membranes. Methods: We compared the immunophenotypes (ABCG2, K3/12, and vimentin) of cells grown on amniotic membranes or plastic surfaces under serum-free conditions or in culture media containing serum or serum replacement components. Results: Immature dental pulp stem cells grown on amniotic membranes under basal conditions are able to maintain their undifferentiated state. Our data also suggest that the culture medium used in the present work can modulate the expression of immature dental pulp stem cell markers, thus inducing epithelial differentiation of these cells in vitro. Conclusions: Our results suggest that the amniotic membrane is a good choice for the growth and transplantation of mesenchymal stem cells, particularly immature dental pulp stem cells, in clinical ocular surface reconstruction.


RESUMO Objetivos: Avaliar a capacidade das células-tronco imaturas da polpa do dente de leite que são células-tronco mesenquimais de origem da crista neural, de se diferenciarem no epitélio corneano para fins de transplante de córnea e engenharia de tecidos quando cultivadas em membrana amnióticas desepitelizadas. Métodos: Foram comparamos so imunofenótipo (ABCG2, CK3/12 e vimentina) de células cultivadas em membranas amnióticas ou em superfícies plásticas sob condições livres de soro ou em meios de cultura contendo soro ou componentes de substituição de soro. Resultados: Células-tronco imaturas da polpa do dente de leite cultivadas sobre membrana amniótica em condições basais são capazes de manter seu estado indiferenciado. Nossos dados também sugerem que o meio de cultura utilizado no presente trabalho pode modular a expressão de marcadores de células-tronco imaturas da polpa do dente de leite, induzindo a diferenciação epitelial destas células in vitro. Conclusão: Nossos resultados sugerem que a membrana amniótica é uma boa escolha para o crescimento e transplante de células-tronco mesenquimais, particularmente as células-tronco imaturas da polpa do dente de leite, na reconstrução da superfície ocular.


Asunto(s)
Humanos , Epitelio Corneal/trasplante , Pulpa Dental/citología , Trasplante de Células Madre Mesenquimatosas/métodos , Andamios del Tejido , Células Madre Mesenquimatosas/citología , Amnios , Factores de Tiempo , Células Cultivadas , Reproducibilidad de los Resultados , Técnica del Anticuerpo Fluorescente , Técnicas de Cultivo de Célula/métodos , Enfermedades de la Córnea/cirugía , Proliferación Celular
18.
Arq. bras. oftalmol ; Arq. bras. oftalmol;82(1): 51-55, Jan.-Feb. 2019. tab, graf
Artículo en Inglés | LILACS | ID: biblio-973878

RESUMEN

ABSTRACT Purpose: This study aimed to determine the variation in diameters of outer and inner apertures of eyedropper tips using a computer vision system. Standardizing the size of eye drop nozzles is crucial to reduce the treatment cost of chronic eye diseases and to ensure a continued use of medication. An eyedropper volume of >20 µL (maximum storage of the conjunctival sac) causes medication wastage and increases treatment costs. Methods: We measured the diameters of the outer and inner apertures of eyedropper tips and evaluated variations in diameters using a computerized visual inspection system. Results: The computer visual inspection system identified anomalies in the apertures of eyedropper tips that resulted in diameter variations. Conclusions: The results of the present study show discrepancies in diameters of eyedropper tips, suggesting a variation in eyedropper size and medication wastage.


RESUMO Objetivo: Este estudo teve como objetivo determinar a variação dos diâmetros das aberturas externa e interna dos bicos conta-gotas utilizando sistema de visão computacional. A padronização do tamanho dos colírios conta-gotas é importante para reduzir o custo do tratamento de doenças crônicas e garantir o uso contínuo de medicamentos. O volume da gota maior do que 20 µl (volume de armazenamento máximo do saco conjuntival) gera desperdício da medicação e aumenta o custo do tratamento. Métodos: Medimos os diâmetros das aberturas externa e interna das pontas dos conta-gotas e avaliamos as variações no diâmetro usando um sistema de inspeção visual computadorizado. Resultados: O sistema de inspeção visual por computador identificou anomalias nas aberturas dos bicos dos frascos conta-gotas que resultaram em variações de diâmetro. Conclusões: Os resultados do presente estudo mostram discrepâncias nos diâmetros dos bicos dos frascos dos conta-gotas, sugerindo uma variação no tamanho das gotas e no desperdício de remédios.


Asunto(s)
Soluciones Oftálmicas/administración & dosificación , Inteligencia Artificial , Embalaje de Medicamentos/normas , Estándares de Referencia , Análisis de Varianza , Administración Oftálmica
19.
Arq. bras. oftalmol ; Arq. bras. oftalmol;82(1): 78-84, Jan.-Feb. 2019. tab
Artículo en Inglés | LILACS | ID: biblio-973874

RESUMEN

ABSTRACT The transparency and maintenance of corneal epithelial integrity are essential for its optical properties and, to preserve these characteristics, the epithelium undergoes continuous renewal. This renewal depends on the control of cell proliferation and differentiation mediated by mitogenic factors responsible for increasing mitoses and stimulating cellular migration. Cell-cell communication plays a pivotal role in epithelial healing process, and several cytokines and growth factors are involved in this process. Understanding the cross-talk and paracrine effects of these cytokines and growth factors released can help in the search for new therapeutic strategies to treat ocular surface diseases.


RESUMO A transparência e a manutenção da integridade epitelial da córnea são essenciais para suas propriedades ópticas e, para preservar tais características, o epitélio sofre renovação contínua. Essa renovação depende do controle da proliferação e diferenciação celular mediadas por fatores mitogênicos responsáveis pelo aumento das mitoses e estímulo à migração celular. A comunicação célula-célula desempenha um papel fundamental no processo de cicatrização epitelial, e várias citocinas e fatores de crescimento estão envolvidos neste processo. Compreender os efeitos cruzados e paracrinos dessas citocinas e fatores de crescimento liberados pode ajudar na busca de novas estratégias terapêuticas para o tratamento de doenças da superfície ocular.


Asunto(s)
Humanos , Cicatrización de Heridas/fisiología , Epitelio Corneal/fisiología , Péptidos y Proteínas de Señalización Intercelular/uso terapéutico , Diferenciación Celular/fisiología , Epitelio Corneal/citología , Enfermedades de la Córnea/terapia , Péptidos y Proteínas de Señalización Intercelular/fisiología , Proliferación Celular/fisiología , Células Epiteliales/fisiología , Fibroblastos/fisiología
20.
Arq Bras Oftalmol ; 82(1): 51-55, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30652766

RESUMEN

PURPOSE: This study aimed to determine the variation in diameters of outer and inner apertures of eyedropper tips using a computer vision system. Standardizing the size of eye drop nozzles is crucial to reduce the treatment cost of chronic eye diseases and to ensure a continued use of medication. An eyedropper volume of >20 µL (maximum storage of the conjunctival sac) causes medication wastage and increases treatment costs. METHODS: We measured the diameters of the outer and inner apertures of eyedropper tips and evaluated variations in diameters using a computerized visual inspection system. RESULTS: The computer visual inspection system identified anomalies in the apertures of eyedropper tips that resulted in diameter variations. CONCLUSIONS: The results of the present study show discrepancies in diameters of eyedropper tips, suggesting a variation in eyedropper size and medication wastage.


Asunto(s)
Inteligencia Artificial , Embalaje de Medicamentos/normas , Soluciones Oftálmicas/administración & dosificación , Administración Oftálmica , Análisis de Varianza , Estándares de Referencia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA