1.
Talanta ; 117: 288-96, 2013 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-24209343

RESUMEN

From the great variety of BODIPY based-chemosensors able to determine Hg(2+), only a small portion has been applied to its determination in environmental and/or biological samples. The lack of studies on the analytical performance of the latter sensors makes interesting the development of investigations oriented to their possible analytical applications. The synthesis of a BODIPY derivative armed with a tetrapod receptor is described. The procedure is based on a previous publication, and the modifications performed to improve the synthesis include alternative procedures with different objectives, as the consecution of a multigram synthesis, improving the low yields of some of the previously proposed procedure steps, simplifying the experimental steps, achieving the desired purity requirements for use with analytical purposes, and enriching the characterization of the implied structures. The characteristics of its selectivity towards Hg(2+) have been investigated, and the OFF-ON fluorometric response, based on a photo-electron transfer (PET) mechanism, served as the base for the development of a method able to determine Hg(2+) in environmental waters at ng mL(-1) levels. The intrinsic fluorescence of the BODIPY core is inhibited and the probe exhibits a weak fluorescence (i.e. "OFF" state due to the deactivating PET effect). Upon complexation, Hg(2+) interacts with the lone-pair electrons on the nitrogen atoms of the receptor moiety so that the electronic transfer from the receptor to the photo-excited fluorophore is slowed down or switched off (i.e. "ON" state due to the suppression of the deactivating PET effect by coordination of the analyte to the probe). Regarding the complex photostability in aqueous solution, it is mandatory to conduct the experiments at darkness due to its photodegradation. The stoichiometry studies indicated a 1:2 relationship for the BODIPY-Hg(2+) complex. The high selectivity towards mercuric ions is considerably influenced by pH, being necessary to conduct the experiments in a pH value higher than 6. Calibration samples were prepared by adding appropriate amounts of Hg(2+) between 20.0-120.0 ng mL(-1), at a constant BODIPY concentration of 1 µmol L(-1). After agitating for 5 min at darkness, phosphate buffer (pH=7.50) was added, and it was diluted to the mark with water. Fluorescence measurements were carried out at 18 °C, exciting at 515 nm, and obtaining fluorescence emission at 538 nm. The method has been satisfactory applied to Hg(2+) determination in environmental water samples.


Asunto(s)
Compuestos de Boro/química , Electrones , Agua Dulce/química , Mercurio/análisis , Receptores Artificiales/química , Contaminantes Químicos del Agua/análisis , Transporte de Electrón , Humanos , Concentración de Iones de Hidrógeno , Procesos Fotoquímicos , Sensibilidad y Especificidad , Espectrometría de Fluorescencia
2.
Talanta ; 85(5): 2368-74, 2011 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-21962655

RESUMEN

This work presents the development of a liquid chromatographic method based on modeling entire fast scan fluorimetric detection second-order data with the multivariate curve resolution alternating least squares algorithm, for the simultaneous determination of five marker pteridines in urine samples. The modeling strategy involves the building of a single MCR-ALS model composed of matrices augmented in the spectral mode, i.e. time profiles remain invariant while spectra may change from sample to sample. This approach allowed us to separate and determine the whole analytes at once. The developed approach enabled us to determine five of the most important metabolic disorder marker pteridines: biopterin, neopterin, isoxanthopterin, pterin and xanthopterin, three of them presenting emission spectra with the same emission wavelength maxima. In addition, some of these analytes present overlapped time profiles. As a consequence of using the entire data sets, a considerable reduction of the data processing experimental time can be achieved. Results are compared with a previous strategy in which data were split in five different regions, and information about the figures of merit of the new strategy compared with the previously reported strategy is reported.


Asunto(s)
Biomarcadores/orina , Cromatografía Líquida de Alta Presión/métodos , Modelos Teóricos , Pteridinas/orina , Espectrometría de Fluorescencia/métodos , Calibración
3.
Talanta ; 83(4): 1098-107, 2011 Jan 30.
Artículo en Inglés | MEDLINE | ID: mdl-21215844

RESUMEN

This overview covers the different chemometric strategies linked to chromatographic methodologies that have been used and presented in the recent literature to cope with problems related to incomplete separation, the presence of unexpected components in the sample, matrix effect and changes in the analytical signal due to pre-treatment of sample. Among the different chemometric strategies it focuses on pre-treatment of data to correct background and time shift of chromatographic peaks and the use of second-order algorithms to cope with overlapping peaks from analytes or from analytes and interferences in liquid chromatography coupled to diode array, fast-scanning fluorescence spectroscopy and mass spectrometry detectors. Finally the review presents the strategies used to deal with changes in the analytical response as result of matrix effect in liquid and gas chromatography, as well as the use of standardization strategies to correct modifications in the analytical signal as a consequence of sample pre-treatment in liquid chromatography.


Asunto(s)
Cromatografía/métodos , Informática/métodos , Estadística como Asunto/métodos , Algoritmos , Calibración , Cromatografía/normas , Estándares de Referencia , Análisis Espectral
4.
J Chromatogr A ; 1211(1-2): 22-32, 2008 Nov 21.
Artículo en Inglés | MEDLINE | ID: mdl-18950779

RESUMEN

In the present work, an analytical method for the simultaneous determination of seven non steroidal anti-inflammatory drugs (naproxen, ketoprofen, diclofenac, piroxicam, indomethacin, sulindac and diflunisal) and the anticonvulsant carbamazepine is reported. The method involves preconcentration and clean-up by solid-phase microextraction using polydimethylsiloxane/divinylbenzene fibers, followed by liquid chromatography with diode array detection analysis. Parameters that affect the efficiency of the solid-phase microextraction step such as soaking solvent, soaking period, desorption period, stirring rate, extraction time, sample pH, ionic strength, organic solvent and temperature were investigated using a Plackett-Burman screening design. Then, the factors presenting significant positive effects on the analytical response (soaking period, stirring rate, stirring time) were considered in a further central composite design to optimize the operational conditions for the solid phase microextraction procedure. Additionally, multiple response simultaneous optimization by using the desirability function was used to find the optimum experimental conditions for the on-line solid-phase microextraction of analytes in river water samples coupled to liquid chromatography and diode array detection. The best results were obtained using a soaking period of 5 min, stirring rate of 1400 rpm and stirring time of 44 min. The use of solid-phase microextraction technique avoided matrix effect and allowed to quantify the analytes in river water samples by using Milli-Q based calibration graphs. Recoveries ranging from 71.6% to 122.8% for all pharmaceuticals proved the accuracy of the proposed method in river water samples. Method detection limits were in the range of 0.5-3.0 microgL(-1) and limits of quantitation (LOQs) were between 1.0 and 4.0 microgL(-1) for pharmaceutical compounds in river water samples. The expanded uncertainty associated to the measurement of the concentration ranged between 8.5% and 29.0% for 20 microgL(-1) of each analyte and between 9.0% and 29.5% for the average of different concentration levels. The main source of uncertainty was the calibration step in both cases.


Asunto(s)
Antiinflamatorios no Esteroideos/análisis , Anticonvulsivantes/análisis , Ríos/química , Microextracción en Fase Sólida/métodos , Contaminantes Químicos del Agua/análisis , Adsorción , Cromatografía Liquida/métodos , Estándares de Referencia , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Microextracción en Fase Sólida/economía , Microextracción en Fase Sólida/instrumentación
5.
J Chromatogr A ; 1179(2): 106-14, 2008 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-18093603

RESUMEN

The effect of piecewise direct standardization (PDS) and baseline correction approaches was evaluated in the performance of multivariate curve resolution (MCR-ALS) algorithm for the resolution of three-way data sets from liquid chromatography with diode-array detection (LC-DAD). First, eight tetracyclines (tetracycline, oxytetracycline, chlorotetracycline, demeclocycline, methacycline, doxycycline, meclocycline and minocycline) were isolated from 250 mL effluent wastewater samples by solid-phase extraction (SPE) with Oasis MAX 500 mg/6 mL cartridges and then separated on an Aquasil C18 150 mm x 4.6mm (5 microm particle size) column by LC and detected by DAD. Previous experiments, carried out with Milli-Q water samples, showed a considerable loss of the most polar analytes (minocycline, oxitetracycline and tetracycline) due to breakthrough. PDS was applied to overcome this important drawback. Conversion of chromatograms obtained from standards prepared in solvent was performed obtaining a high correlation with those corresponding to the real situation (r2 = 0.98). Although the enrichment and clean-up steps were carefully optimized, the sample matrix caused a large baseline drift, and also additive interferences were present at the retention times of the analytes. These problems were solved with the baseline correction method proposed by Eilers. MCR-ALS was applied to the corrected and uncorrected three-way data sets to obtain spectral and chromatographic profiles of each tetracycline, as well as those corresponding to the co-eluting interferences. The complexity of the calibration model built from uncorrected data sets was higher, as expected, and the quality of the spectral and chromatographic profiles was worse.


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Tetraciclinas/análisis , Contaminantes Químicos del Agua/análisis , Algoritmos , Modelos Teóricos , Tetraciclinas/aislamiento & purificación , Eliminación de Residuos Líquidos
6.
J Pharm Biomed Anal ; 31(1): 39-46, 2003 Feb 05.
Artículo en Inglés | MEDLINE | ID: mdl-12560047

RESUMEN

A capillary zone electrophoresis (CZE) method has been developed to separate and quantitate naphazoline (NAPH), dyphenhydramine (DIP) and phenylephrine (PHE) in nasal solutions. Samples were diluted 1:25 in ultrapure water and injected at the anodic end. A central composite design has been used to optimise the experimental conditions for a complete and fast separation of the active ingredients studied. Critical parameters such as voltage, pH and buffer concentration have been studied to evaluate how they affect responses such as resolution and migration times. Separation was performed on a silica capillary with 75 microm I.D. and 70 cm total length at an applied voltage of 17.7 kV with a phosphate run buffer of pH 3.72 and 0.063 mol l(-1). Calibration curves were prepared for NAPH, DIP and PHE. For each analyte, the correlation coefficients were >0.999 (n=15). The RSD% of six replicate injections for each analyte were reasonably good. The method was applied to the quantitation of the three components in a commercial dosage form. The proposed method has the advantage of needing a very simple sample pretreatment and being faster than a typical HPLC chromatographic method.


Asunto(s)
Difenhidramina/análisis , Nafazolina/análisis , Fenilefrina/análisis , Administración Intranasal , Algoritmos , Electroforesis Capilar , Excipientes , Concentración de Iones de Hidrógeno , Indicadores y Reactivos , Soluciones Farmacéuticas , Reproducibilidad de los Resultados , Espectrofotometría Ultravioleta
7.
Int J Pharm ; 229(1-2): 205-11, 2001 Oct 23.
Artículo en Inglés | MEDLINE | ID: mdl-11604273

RESUMEN

The use of multivariate spectrophotometric calibration for the simultaneous determination of dexamethasone and two typical excipients (creatinine and propylparaben) in injections is presented. The resolution of the three-component mixture in a matrix of excipients has been accomplished by using partial least-squares (PLS-1). Notwithstanding the elevated degree of spectral overlap, they have been rapidly and simultaneously determined with high accuracy and precision (comparable to the HPLC pharmacopeial method), with no interference, and without resorting to extraction procedures using non-aqueous solvents. A simple and fast method for wavelength selection in the calibration step is used, based on the minimisation of the predicted error sum of squares (PRESS) calculated as a function of a moving spectral window.


Asunto(s)
Creatinina/análisis , Dexametasona/análisis , Parabenos/análisis , Calibración , Cromatografía Líquida de Alta Presión , Indicadores y Reactivos , Análisis Multivariante , Reproducibilidad de los Resultados , Espectrofotometría Ultravioleta
8.
Analyst ; 126(7): 1105-12, 2001 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-11478644

RESUMEN

A newly developed multivariate method involving net analyte preprocessing (NAP) was tested using central composite calibration designs of progressively decreasing size regarding the multivariate simultaneous spectrophotometric determination of three active components (phenylephrine, diphenhydramine and naphazoline) and one excipient (methylparaben) in nasal solutions. Its performance was evaluated and compared with that of partial least-squares (PLS-1). Minimisation of the calibration predicted error sum of squares (PRESS) as a function of a moving spectral window helped to select appropriate working spectral ranges for both methods. The comparison of NAP and PLS results was carried out using two tests: (1) the elliptical joint confidence region for the slope and intercept of a predicted versus actual concentrations plot for a large validation set of samples and (2) the D-optimality criterion concerning the information content of the calibration data matrix. Extensive simulations and experimental validation showed that, unlike PLS, the NAP method is able to furnish highly satisfactory results when the calibration set is reduced from a full four-component central composite to a fractional central composite, as expected from the modelling requirements of net analyte based methods.


Asunto(s)
Preparaciones Farmacéuticas/química , Espectrofotometría/métodos , Calibración
9.
Talanta ; 52(5): 909-20, 2000 Aug 16.
Artículo en Inglés | MEDLINE | ID: mdl-18968052

RESUMEN

The use of multivariate spectrophotometric calibration for the simultaneous determination of several active components and excipients in ophthalmic solutions is presented. The resolution of five-component mixtures of phenylephrine, chloramphenicol, antipyrine, methylparaben and thimerosal has been accomplished by using partial least-squares (PLS-1) and a variant of the so-called hybrid linear analysis (HLA). Notwithstanding the presence of a large number of components and their high degree of spectral overlap, they have been determined simultaneously with high accuracy and precision, with no interference, rapidly and without resorting to extraction procedures using non aqueous solvents. A simple and fast method for wavelength selection in the calibration step is presented, based on the minimisation of the predicted error sum of squares (PRESS) calculated as a function of a moving spectral window.

10.
Anal Chem ; 71(19): 4361-8, 1999 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-10517151

RESUMEN

Tetracycline has been determined in human serum samples by a combination of: (1) synchronous fluorescence spectra of whole sera treated with Mg2+, and (2) the multivariate calibration methods of partial least-squares (PLS-1) and a variant of the recently introduced hybrid linear analysis (HLA), which does not require the knowledge of pure-component spectra. The calibration set was designed with 50 sera spiked with concentrations of tetracycline in the range 0.0-4.0 micrograms mL-1'. Studies concerning validation, precision, accuracy and figures of merit (selectivity, sensitivity and limit of determination) were also carried out. A novel wavelength-selection procedure was applied to minimize the effect of nonmodeled interferents present in serum samples containing bilirubin, triglycerides, and salicylate. Overall, the performance of the newly developed HLA approach seems to be better than that of PLS-1.


Asunto(s)
Análisis de los Mínimos Cuadrados , Modelos Lineales , Espectrometría de Fluorescencia/métodos , Tetraciclina/sangre , Calibración , Humanos , Magnesio/sangre , Magnesio/química , Magnesio/metabolismo , Análisis Multivariante , Sensibilidad y Especificidad , Tetraciclina/química , Tetraciclina/metabolismo
11.
Talanta ; 49(4): 793-800, 1999 Jul 12.
Artículo en Inglés | MEDLINE | ID: mdl-18967655

RESUMEN

The mucolitic bromhexine [N-(2-amino-3,5-dibromobenzyl)-N-methylcyclohexylamine] has been determined in cough suppressant syrups by multivariate spectrophotometric calibration, together with partial least-squares (PLS-1) and hybrid linear analysis (HLA). Notwithstanding the spectral overlapping between bromhexine and syrup excipients, as well as the intrinsic variability of the latter in unknown samples, the recoveries are excellent. A novel method of wavelength selection was also applied, based on the concept of net analyte signal regression, as adapted to the HLA methodology. This method allows one to improve the performance of both PLS-1 and HLA in samples containing nonmodeled interferences.

12.
J Pharm Biomed Anal ; 20(1-2): 255-61, 1999 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-10704030

RESUMEN

The use of multivariate spectrophotometric calibration is reported for the analysis of two decongestant tablets, where paracetamol is the principal component and diphenhydramine or phenylpropanolamine are the minor components. The resolution of these mixtures has been accomplished without prior separation or derivatisation, by using partial least-squares (PLS-1) regression analysis of electronic absorption spectral data. Although the molar ratios of paracetamol to the minor components were 38:1 and 25:1 respectively, the latter have been determined with high accuracy and precision, and with no interference from tablet excipients. PLS is able to take into account small deviations of paracetamol from linearity in the studied concentration range. The application of classical least-squares (CLS) analysis yields unsatisfactory results, due to the low absorbances of the minor components within the range where all components obey Beer's law.


Asunto(s)
Acetaminofén/análisis , Analgésicos no Narcóticos/análisis , Difenhidramina/análisis , Antagonistas de los Receptores Histamínicos H1/análisis , Descongestionantes Nasales/análisis , Fenilpropanolamina/análisis , Algoritmos , Análisis de Varianza , Calibración , Combinación de Medicamentos , Indicadores y Reactivos , Análisis de los Mínimos Cuadrados , Espectrofotometría Ultravioleta , Comprimidos
13.
J Pharm Biomed Anal ; 20(4): 681-6, 1999 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-10704137

RESUMEN

The use of multivariate spectrophotometric calibration is presented for the simultaneous determination of the active components of tablets used in the treatment of pulmonary tuberculosis. The resolution of ternary mixtures of rifampicin, isoniazid and pyrazinamide has been accomplished by using partial least squares (PLS-1) regression analysis. Although the components show an important degree of spectral overlap, they have been simultaneously determined with high accuracy and precision, rapidly and with no need of nonaqueous solvents for dissolving the samples. No interference has been observed from the tablet excipients. A comparison is presented with the related multivariate method of classical least squares (CLS) analysis, which is shown to yield less reliable results due to the severe spectral overlap among the studied compounds. This is highlighted in the case of isoniazid, due to the small absorbances measured for this component.


Asunto(s)
Antituberculosos/análisis , Isoniazida/análisis , Pirazinamida/análisis , Rifampin/análisis , Antituberculosos/química , Isoniazida/química , Análisis Multivariante , Pirazinamida/química , Rifampin/química , Espectrofotometría/métodos , Comprimidos
14.
Talanta ; 47(1): 103-8, 1998 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-18967308

RESUMEN

The use of multivariate spectrophotometric calibration for the simultaneous determination of the active components of antiepileptic tablets is presented. The resolution of binary mixtures of phenobarbital and phenytoin has been accomplished by using partial least squares (PLS-1) regression analysis. Although the components show an important degree of spectral overlap, they have been simultaneously determined with high accuracy, with no interference from tablet excipients. A comparison is presented with the related multivariate method of classical least squares (CLS) analysis, which is shown to yield less reliable results due to the severe spectral overlap presented by the studied compounds. A statistical measure for the spectral overlap is proposed.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA