Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Science ; 385(6706): 322-327, 2024 Jul 19.
Artículo en Inglés | MEDLINE | ID: mdl-38963876

RESUMEN

One of Earth's most fundamental climate shifts, the greenhouse-icehouse transition 34 million years ago, initiated Antarctic ice sheet buildup, influencing global climate until today. However, the extent of the ice sheet during the Early Oligocene Glacial Maximum (~33.7 to 33.2 million years ago) that immediately followed this transition-a critical knowledge gap for assessing feedbacks between permanently glaciated areas and early Cenozoic global climate reorganization-is uncertain. In this work, we present shallow-marine drilling data constraining earliest Oligocene environmental conditions on West Antarctica's Pacific margin-a key region for understanding Antarctic ice sheet evolution. These data indicate a cool-temperate environment with mild ocean and air temperatures that prevented West Antarctic Ice Sheet formation. Climate-ice sheet modeling corroborates a highly asymmetric Antarctic ice sheet, thereby revealing its differential regional response to past and future climatic change.

2.
Science ; 343(6174): 999-1001, 2014 Feb 28.
Artículo en Inglés | MEDLINE | ID: mdl-24557837

RESUMEN

Pine Island Glacier, a major outlet of the West Antarctic Ice Sheet, has been undergoing rapid thinning and retreat for the past two decades. We demonstrate, using glacial-geological and geochronological data, that Pine Island Glacier (PIG) also experienced rapid thinning during the early Holocene, around 8000 years ago. Cosmogenic (10)Be concentrations in glacially transported rocks show that this thinning was sustained for decades to centuries at an average rate of more than 100 centimeters per year, which is comparable with contemporary thinning rates. The most likely mechanism was a reduction in ice shelf buttressing. Our findings reveal that PIG has experienced rapid thinning at least once in the past and that, once set in motion, rapid ice sheet changes in this region can persist for centuries.


Asunto(s)
Cubierta de Hielo , Islas , Berilio/análisis , Movimiento (Física) , Radioisótopos/análisis
3.
Internist (Berl) ; 46(1): 92-6, 2005 Jan.
Artículo en Alemán | MEDLINE | ID: mdl-15645195

RESUMEN

A 62 year old patient underwent an intraoperative pancreas biopsy because of a pancreas head process. On 13(th) and 20(th) postoperative day a short syncope episode occurred. On that days calcium blood levels were 1,82 and 1,74 mmol/l, respectively. On 13(th) postoperative day QT(c) interval was 565 ms. On 26(th) postoperative day the patient was resuscitated because of torsade de pointes tachycardia. His actual calcium blood level was 1,47 mmol/l and QT(c) interval 627 ms. An extensive diagnostic work-up revealed no evidence of cardiac disease. After calcium substitution QT interval normalised. During a follow-up period of 16 months the patient remained without symptoms.


Asunto(s)
Reanimación Cardiopulmonar , Hipocalcemia/complicaciones , Hipocalcemia/tratamiento farmacológico , Síndrome de QT Prolongado/etiología , Síndrome de QT Prolongado/prevención & control , Torsades de Pointes/etiología , Torsades de Pointes/prevención & control , Calcio/uso terapéutico , Humanos , Hipocalcemia/diagnóstico , Síndrome de QT Prolongado/diagnóstico , Masculino , Persona de Mediana Edad , Enfermedades Raras , Torsades de Pointes/diagnóstico , Resultado del Tratamiento
4.
Nature ; 390(6658): 357-63, 1997 Nov 27.
Artículo en Inglés | MEDLINE | ID: mdl-11536816

RESUMEN

In 1995, an expedition on board the research vessel FS Polarstern explored the impact site of the Eltanin asteroid in the Southern Ocean, the only known asteroid impact into a deep ocean basin. Analyses of the geological record of the impact region place the event in the late Pliocene (approximately 2.15 Myr) and constrain the size of the asteroid to be >1 km. The explosive force inferred for this event places it at the threshold of impacts believed to have global consequences, and its study should therefore provide a baseline for the reconstruction and modelling of similar events, which are common on geological timescales.


Asunto(s)
Evolución Planetaria , Fósiles , Sedimentos Geológicos/análisis , Geología , Planetas Menores , Silicatos de Aluminio/análisis , Animales , Regiones Antárticas , Arcilla , Diatomeas , Planeta Tierra , Eucariontes , Fenómenos Geológicos , Iridio , Magnetismo , Océano Pacífico , Paleontología , América del Sur
5.
Int J Card Imaging ; 12(1): 47-59, 1996 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-8847454

RESUMEN

The accuracy of multichannel magnetocardiography (MCG) for the non-invasive localization of cardiac arrhythmias was investigated. A non-magnetic catheter was used in phantom studies and for cardiac pacing of 6 patients. In a clinical setting, 32 patients with WPW-syndrome, 37 patients with premature ventricular complexes and 12 patients with ventricular tachycardia were studied and the MCG results compared to reference methods, including invasive electrophysiological mapping. Phantom and pacing studies demonstrated the spatial localization accuracy to be better than 15 mm for a dipole-to-dewar distance below 15 cm. In all patients with structural cardiac disease, the ectopic focus was localized at the margin of the damaged area, serving as a proof of MCG localization. Invasive mapping confirmed the MCG result whenever performed (42 patients). In 11 patients (9 WPW, 2 VT) the MCG localization result was verified by successful HF catheter ablation as a gold standard. MCG permits the non-invasive localization of cardiac arrhythmias with high spatial accuracy. MCG guided HF catheter ablation constitutes a new concept of non-invasive localization and minimally invasive causal therapy.


Asunto(s)
Electrocardiografía , Magnetismo , Procesamiento de Señales Asistido por Computador , Taquicardia Ventricular/diagnóstico , Complejos Prematuros Ventriculares/diagnóstico , Síndrome de Wolff-Parkinson-White/diagnóstico , Estimulación Cardíaca Artificial , Ablación por Catéter , Humanos , Fantasmas de Imagen , Reproducibilidad de los Resultados , Taquicardia Ventricular/cirugía , Síndrome de Wolff-Parkinson-White/cirugía
6.
Pacing Clin Electrophysiol ; 19(1): 18-25, 1996 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-8848372

RESUMEN

INTRODUCTION: The extraction of chronically implanted and infected pacemaker and defibrillator leads is an important issue. This article describes the experience gathered between 1990 and 1994 by seven European centers regarding a locking stylet that is uniformly applicable for a wide variety of internal pacing coil diameters. This interventional locking stylet for lead extraction has an outer diameter of 0.4 mm (0.016 inches). The stylet consists of a hollow shaft in which an inner traction wire is embedded. At the tip of the inner traction wire an anchoring mechanism, which can be opened by retraction, is applied. Removal attempts were made for 150 leads, 110 in ventricular and 40 in atrial positions. RESULTS: Complete removal was possible in 122 cases (81%). Partial removal was possible in 18 cases (12%). Failure to remove the lead with the extraction stylet was experienced in 10 cases (7%). In seven patients, the leads were removed by cardiothoracic surgery; 3 defective leads were left in place. There were no serious complications associated with the procedure. None of the patients died. CONCLUSION: The experience with this extraction stylet for lead removal has shown good results. Despite a low complication rate thus far, each case for lead removal should be judged on the individual basis of benefit-to-risk ratio.


Asunto(s)
Desfibriladores Implantables , Electrodos Implantados , Marcapaso Artificial , Anciano , Desfibriladores Implantables/efectos adversos , Electrodos Implantados/efectos adversos , Diseño de Equipo , Falla de Equipo , Humanos , Marcapaso Artificial/efectos adversos , Instrumentos Quirúrgicos
7.
Biomed Tech (Berl) ; 40(6): 160-7, 1995 Jun.
Artículo en Alemán | MEDLINE | ID: mdl-7632869

RESUMEN

The monophasic action potential (MAP) represents a summed signal formed by overlapping action potentials of myocardial cells close to the tip of the lead. Analysis of the MAP therefore provides detailed information about the electrophysiological effects of autonomous nervous and pharmacological influences on the myocardium, for example adrenergic or cholinergic stimulation of the heart. All known MAP recordings were obtained with Ag/AgCl electrodes, which, thanks to their low polarization properties, ensure reliable MAP measurement. Owing to their toxicity and inadequate long-term stability, however, Ag/AgCl electrodes cannot be implanted. With the aim of making MAP measurement available for implantable devices, fractally coated leads were therefore developed. The aim of the present study was to evaluate the in vivo measurement of fractally coated leads which are characterized by negligible polarization, low impedance over a wide frequency range, high biocompatibility and good long-term stability. In addition, as a result of their extremely high Helmholtz capacities (up to 50 mF/cm2), fractally coated leads permit stimulation and virtually undisturbed recording of MAP with the same pair of electrodes. For the evaluation of MAP measurements with fractally coated leads, a quadrupolar catheter enabling simultaneous MAP recordings with 2 Ag/AgCl electrodes and 2 fractally coated leads was devised. The stimulation pulses were always applied via the fractally coated leads. With both types of electrode, with spontaneous excitation and stimulation, the well-known MAP morphology, with amplitudes of between 10 and 25 mV in the ventricle, and between 5 and 10 mV in the atrium, was seen.(ABSTRACT TRUNCATED AT 250 WORDS)


Asunto(s)
Electrocardiografía/instrumentación , Electrodos Implantados , Marcapaso Artificial , Atropina/farmacología , Electrocardiografía/efectos de los fármacos , Electrocardiografía Ambulatoria/efectos de los fármacos , Electrocardiografía Ambulatoria/instrumentación , Diseño de Equipo , Fractales , Humanos , Iridio , Ensayo de Materiales , Metaproterenol/farmacología , Procesamiento de Señales Asistido por Computador/instrumentación , Plata , Compuestos de Plata , Propiedades de Superficie , Titanio
8.
Eur Heart J ; 13 Suppl E: 65-8, 1992 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-1478212

RESUMEN

In six patients with normal left ventricles and seven post-myocardial infarction patients cardiodynamic changes during tilt and acute nitrate medication were investigated. The conductance catheter was used for on-line registration of left ventricular volumes and a microtip manometer for high-fidelity pressure recordings. We analysed left ventricular end-diastolic volume index (EDVI) ejection fraction (EF), cardiac index (CI), heart rate (HR), end-systolic pressure (ESP) and end-diastolic pressure (EDP) in the supine position and 30 s after passive upright tilt. Supine and standing measurements were performed without medication and 2 min after acute nitrate medication (0.8 mg sublingual nitroglycerin). After unloading by upright tilt there was a similar reduction of average EDVI in the control group (-18 +/- 7 ml.m2) and in the post-infarction group (-21 +/- 18 ml.m2). The effect of nitroglycerin on EDVI (-12 +/- 4 ml.m2 control, -7 +/- 6 ml.m2 post-infarction) was less than the effect of upright tilt. EF in the control group improved by +8 +/- 5% (in absolute values) during passive tilt; the combined effect of tilt and nitrate was +12 +/- 6% EF (p < 0.05). In the post-infarction group EF did not change significantly during tilt and/or nitrate therapy. In the patients with normal regional ventricular function, CI during tilt was maintained at a constant level. In the post-infarction group the reduction in CI was not significant. Although the reduction in EDVI was similar in the control and infarction groups, the infarction group did not respond to the cardiodynamic change by increasing EF.(ABSTRACT TRUNCATED AT 250 WORDS)


Asunto(s)
Insuficiencia Cardíaca/tratamiento farmacológico , Contracción Miocárdica/efectos de los fármacos , Nitroglicerina/uso terapéutico , Postura , Función Ventricular Izquierda/efectos de los fármacos , Administración Sublingual , Presión Sanguínea/efectos de los fármacos , Presión Sanguínea/fisiología , Cateterismo Cardíaco/instrumentación , Gasto Cardíaco/efectos de los fármacos , Gasto Cardíaco/fisiología , Volumen Cardíaco/efectos de los fármacos , Volumen Cardíaco/fisiología , Diástole/efectos de los fármacos , Diástole/fisiología , Electrocardiografía/instrumentación , Femenino , Insuficiencia Cardíaca/fisiopatología , Frecuencia Cardíaca/efectos de los fármacos , Frecuencia Cardíaca/fisiología , Humanos , Masculino , Persona de Mediana Edad , Contracción Miocárdica/fisiología , Infarto del Miocardio/tratamiento farmacológico , Infarto del Miocardio/fisiopatología , Nitroglicerina/administración & dosificación , Postura/fisiología , Volumen Sistólico/efectos de los fármacos , Volumen Sistólico/fisiología , Función Ventricular Izquierda/fisiología
9.
Eur Heart J ; 13 Suppl E: 91-8, 1992 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-1478217

RESUMEN

The influence of heart rate (HR) and AV delay (AVD) on left ventricular haemodynamics was studied in 12 patients classified as having coronary heart disease (CHD), hypertensive heart disease (HHD), dilated cardiomyopathy (DCM) or who served as controls. Using the conductance catheter technique, haemodynamics were measured during pacing rates of 80 to 180 beat.min-1 at AV delays of 0 to 240 ms. A 3-D linear regression analysis of the data quantified the influence of HR and AVD in principle for each group. An increase in HR resulted in a rise in the cardiac index without changing ejection fraction in the control group only, but led to a decrease in these parameters in HHD and DCM; cardiac index remained constant in CHD. CHD patients frequently had a more pronounced left ventricular end-diastolic pressure (LVEDP) elevation with higher HR, whereas left ventricular end-diastolic volume (LVEDV) and stroke volume decreased. In patients with HHD, lengthening of the AVD resulted in an increase in LVEDV and a decrease in LVEDP and left ventricular end-systolic volume (LVESV) leading to a higher ratio of stroke volume to LVEDP than in the other subsets. In DCM, longer AVD also resulted in a higher SV/LVEDP ratio, but in contrast to HHD the influence of AVD variation on LVEDP and therefore on the LVEDV/LVEDP ratio was missing.


Asunto(s)
Nodo Atrioventricular/fisiopatología , Cardiomiopatía Dilatada/fisiopatología , Enfermedad Coronaria/fisiopatología , Frecuencia Cardíaca/fisiología , Ventrículos Cardíacos/fisiopatología , Hemodinámica/fisiología , Hipertrofia Ventricular Izquierda/fisiopatología , Contracción Miocárdica/fisiología , Infarto del Miocardio/fisiopatología , Adulto , Anciano , Volumen Sanguíneo/fisiología , Cateterismo Cardíaco/instrumentación , Estimulación Cardíaca Artificial , Volumen Cardíaco/fisiología , Gráficos por Computador , Diástole/fisiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Volumen Sistólico/fisiología , Sístole/fisiología , Función Ventricular Izquierda/fisiología
10.
Eur Heart J ; 13 Suppl E: 99-103, 1992 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-1478218

RESUMEN

The aim of the study was to delineate the influence of the ventriculo-atrial interval (VAI) in tachycardia with regard to the underlying heart disease. Haemodynamic studies were performed by the conductance catheter technique during paced tachycardia with a HR of 140, 160 and 180 beat.min-1 at various VAI in 10 patients; three with coronary heart disease (CHD), three with hypertensive heart disease (HHD) and four serving as controls. The influence of the VAI accounted for an overall change in cardiac index (CI) of 30 +/- 14%. Alterations in left ventricular peak systolic pressure (LVPSP) depending on VAI were significantly higher (P < 0.01) in CHD patients (32 +/- 9%) than in other groups (14 +/- 9% in the controls and 17 +/- 8% in HHD patients). The influence of VAI on left ventricular end-diastolic pressure (LVEDP) did not differ between the subgroups and accounted for a mean overall change of 32 +/- 14%. Atrial activation during the last third of the cardiac cycle led to the highest values of CI, LVEDP and LVPSP in the control group, whereas in HHD and CHD groups minimal values of CI were correlated with maxima of LVEDP and LVPSP. Conversely, with atrial activation during the medium third of the cardiac cycle minima of CI and LVEDP were observed in the controls, whereas in HHD and CHD patients the highest cardiac index coincided with the lowest LVEDP. Thus tachycardias have different haemodynamic effects depending on the nature of myocardial impairment and the timing of AV coupling.


Asunto(s)
Enfermedad Coronaria/fisiopatología , Hemodinámica/fisiología , Hipertrofia Ventricular Izquierda/fisiopatología , Infarto del Miocardio/fisiopatología , Taquicardia por Reentrada en el Nodo Atrioventricular/fisiopatología , Nodo Atrioventricular/fisiopatología , Presión Sanguínea/fisiología , Volumen Sanguíneo/fisiología , Cateterismo Cardíaco/instrumentación , Estimulación Cardíaca Artificial , Volumen Cardíaco/fisiología , Diástole/fisiología , Femenino , Frecuencia Cardíaca/fisiología , Humanos , Masculino , Persona de Mediana Edad , Contracción Miocárdica/fisiología , Volumen Sistólico/fisiología , Sístole/fisiología , Función Ventricular Izquierda/fisiología
11.
Fortschr Med ; 109(30): 599-600, 1991 Oct 20.
Artículo en Alemán | MEDLINE | ID: mdl-1722187

RESUMEN

Magnetocardiography is a non-invasive biomagnetic technique for measuring magnetic fields produced at the surface of the body when the heart is stimulated to beat. The measurement is contact-free and is independent of tissue resistance. For the first time, magnetocardiography employing multi-channel systems permits the accurate, non-invasive localization of accessory conduction pathways and ectopic ventricular activity.


Asunto(s)
Complejos Cardíacos Prematuros/fisiopatología , Electrocardiografía/instrumentación , Campos Electromagnéticos , Sistema de Conducción Cardíaco/fisiopatología , Procesamiento de Señales Asistido por Computador/instrumentación , Síndrome de Wolff-Parkinson-White/fisiopatología , Ventrículos Cardíacos/fisiopatología , Humanos
12.
Pacing Clin Electrophysiol ; 14(10): 1544-53, 1991 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-1721137

RESUMEN

Concerning the pathogenetic mechanism of idiopathic long QT syndrome (LQTS), the hypothesis of a specific sympathetic imbalance has gained general acceptance, but its validity has never been proven. To test this hypothesis I-123-MIBG, an analogue of norepinephrine and guanethidine, was used to provide scintigraphic display of the efferent cardiac sympathetic innervation. Twelve members of four LQTS families (mean age 38.2 +/- 17.2 years, eight males) and eight healthy volunteers (mean age 48.2 +/- 13.3 years, five males) were studied by means of I-123-MIBG single photon emission computed tomography (SPECT). A quantitative analysis of all scans was performed. All scans of the healthy volunteers show a uniform tracer uptake with sometimes slightly decreased activity in the apex. (1) All patients with QTc greater than 440 msec (n = 5); (2) all, who had suffered from at least one episode of torsade de pointes, ventricular fibrillation (VF) or syncope (n = 5); and (3) all symptomatic patients with QTc prolongation (n = 4) have reduced or abolished (P less than 0.02) MIBG uptakes in the inferior and inferior septal parts of the left ventricle (congenital myocardial sympathetic dysinnervation [CMSD]). Additionally, one female without symptoms or QTc prolongation (LQT) shows an abnormal MIBG SPECT similar to the one of her daughter, who has LQT and symptoms. One male without LQT, who had suffered from VF shows CMSD similar to his father, who has LQT, but no symptoms. All members of the families with normal MIBG SPECTs have neither LQT nor symptoms. In all families CMSD fulfills the criteria of autosomal-dominant inheritance. Normal QTc-interval predicted only in 57% normal cardiac sympathetic innervation in the present LQTS families. Therefore, quantitative I-123-MIBG SPECT enables to identify myocardial sympathetic dysinnervation as structural defect in LQTS. CMSD is associated with and without LQT and presents a pattern of autosomal-dominant inheritance. LQT at rest or during exercise was specific (100%), but less sensitive (63%) in the assessment of CMSD than I-123-MIBG SPECT.


Asunto(s)
Corazón/inervación , Síndrome de QT Prolongado/genética , Sistema Nervioso Simpático/fisiopatología , 3-Yodobencilguanidina , Adulto , Estimulación Cardíaca Artificial , Femenino , Genes Dominantes , Corazón/diagnóstico por imagen , Humanos , Radioisótopos de Yodo , Yodobencenos , Síndrome de QT Prolongado/diagnóstico por imagen , Síndrome de QT Prolongado/fisiopatología , Masculino , Linaje , Simpaticolíticos , Tomografía Computarizada de Emisión de Fotón Único
13.
Radiology ; 180(3): 685-92, 1991 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-1714612

RESUMEN

The magnetic fields caused by electrical activity of the human heart can be coherently measured with a highly sensitive, multichannel, superconducting quantum interference-device system and can enable noninvasive localization of the underlying electrical activity. The magnetocardiograms (MCGs) of 10 patients with spontaneous premature ventricular complexes (PVCs), three patients with ventricular tachycardia (VT), and four healthy subjects with induced paced beats were recorded for 2-15 minutes. After correction for superimposed repolarization activity, the site of origin of the arrhythmias was localized from the magnetic field distribution at the onset of the ectopic beats. The localization results of paced beats showed an error of a few millimeters in relation to the position of the catheter tip. The results of spontaneous PVC and VT were confirmed with endocardial mapping or associated with ischemic lesions. The authors conclude that multichannel magnetocardiographic studies enable the completely noninvasive localization of ventricular arrhythmias.


Asunto(s)
Arritmias Cardíacas/diagnóstico , Magnetismo , Adulto , Anciano , Arritmias Cardíacas/fisiopatología , Complejos Cardíacos Prematuros/diagnóstico , Complejos Cardíacos Prematuros/fisiopatología , Estimulación Cardíaca Artificial , Electrocardiografía , Femenino , Corazón/fisiopatología , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Taquicardia/diagnóstico , Taquicardia/fisiopatología
14.
Int J Card Imaging ; 7(3-4): 217-23, 1991.
Artículo en Inglés | MEDLINE | ID: mdl-1726471

RESUMEN

The magnetic fields caused by the human heart's electrical activity were coherently recorded with a biomagnetic multichannel system (KRENIKON) during 1 to 10 minutes in 49 patients. 31 to 37 magnetic channels were recorded simultaneously with the ECG and respiration. Comparison of a magnetic index and the Sokolow-Lyon index to echocardiographic findings in the quantification of left ventricular hypertrophy demonstrated the superiority of the magnetocardiogram (MCG) as compared to the ECG. The magnetocardiographic investigation of patients with WPW-Syndrome, ventricular extrasystoles, ventricular tachycardia, and paced ventricular beats demonstrated that multichannel magnetocardiography permits the non-invasive three dimensional localization of arrhythmogenic tissue with high spatial accuracy.


Asunto(s)
Complejos Cardíacos Prematuros/diagnóstico , Cardiomegalia/diagnóstico , Electrocardiografía/métodos , Fenómenos Electromagnéticos/métodos , Sistema de Conducción Cardíaco/fisiopatología , Modelos Cardiovasculares , Taquicardia/diagnóstico , Síndrome de Wolff-Parkinson-White/diagnóstico , Potenciales de Acción/fisiología , Adulto , Complejos Cardíacos Prematuros/fisiopatología , Cardiomegalia/fisiopatología , Electrocardiografía/instrumentación , Fenómenos Electromagnéticos/instrumentación , Reacciones Falso Negativas , Femenino , Ventrículos Cardíacos/fisiopatología , Humanos , Imagen por Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Taquicardia/fisiopatología , Síndrome de Wolff-Parkinson-White/fisiopatología
15.
Biomed Tech (Berl) ; 35 Suppl 3: 160-1, 1990.
Artículo en Inglés | MEDLINE | ID: mdl-1706631

RESUMEN

A method has been developed to eliminate disturbing magnetic signals in the biomagnetic localization of arrhythmogenic sources in the heart. The procedure consists of two steps: Superimposed background activity of the heart is eliminated by subtraction of a template of pure background activity. Systematic and electronic offset is subsequently eliminated by baseline-correction during periods of zero activity. The method was applied to several kinds of arrhythmias. It was demonstrated that elimination of background activity is the prerequesite for exact localization and that the proposed procedure yields correct results.


Asunto(s)
Complejos Cardíacos Prematuros/fisiopatología , Electrocardiografía/instrumentación , Campos Electromagnéticos , Procesamiento de Señales Asistido por Computador/instrumentación , Taquicardia Supraventricular/fisiopatología , Síndrome de Wolff-Parkinson-White/fisiopatología , Algoritmos , Complejos Cardíacos Prematuros/diagnóstico , Sistema de Conducción Cardíaco/fisiopatología , Humanos , Marcapaso Artificial , Taquicardia Supraventricular/diagnóstico , Síndrome de Wolff-Parkinson-White/diagnóstico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA