1.
Physiol Meas ; 42(7)2021 07 28.
Artículo en Inglés | MEDLINE | ID: mdl-34167097

RESUMEN

Objective.We will describe our clinical experience using electrical impedance tomography (EIT) in the management of mechanical ventilation in patients with acute respiratory failure and to determine to which extent EIT-guided positive end-expiratory pressure (PEEP) setting differed from clinically set values.Approach.We conducted a retrospective, observational cohort study performed in a hub centre for the treatment of acute respiratory failure and veno-venous extracorporeal membrane oxygenation (ECMO).Main results.Between January 2017 and December 2019, EIT was performed 54 times in 41 patients, not feasible only in one case because of signal instability. More than 50% was on veno-venous ECMO support. In 16 cases (30%), EIT was used for monitoring mechanical ventilation, i.e. to evaluate recruitability or sigh setting. In 37 cases (70%), EIT was used to set PEEP both with incremental (11 cases in nine patients) and decremental (26 cases, 18 patients) PEEP trial. Clinical PEEP before the decremental PEEP trial (PEEPPRE) was 14.1 ± 3.4 cmH2O and clinical PEEP set by clinicians after the PEEP trial (PEEPPOST) was 13.6 ± 3.1 (p = ns). EIT analyses demonstrated that more hypoxic patients were higher derecruited when compared to less hypoxic patients that were, on the contrary, more overdistended (p < 0.05). No acute effects of PEEP adjustment based on EIT on respiratory mechanics or regional EIT parameters modification were observed.Significance.The variability of EIT findings in our population confirmed the need to provide ventilation settings individually tailored and EIT was confirmed to be an optimal useful clinical bedside noninvasive tool to provide real-time monitoring of the PEEP effect and ventilation distribution.


Asunto(s)
Respiración con Presión Positiva , Insuficiencia Respiratoria , Impedancia Eléctrica , Humanos , Insuficiencia Respiratoria/terapia , Estudios Retrospectivos , Tomografía
2.
Ann Intensive Care ; 10(1): 39, 2020 Apr 07.
Artículo en Inglés | MEDLINE | ID: mdl-32266600

RESUMEN

BACKGROUND: Pendelluft, the movement of gas within different lung regions, is present in animal models of assisted mechanical ventilation and associated with lung overstretching. Due to rebreathing of CO2 as compared to fresh gas, pendelluft might reduce ventilatory efficiency possibly exacerbating patient's respiratory workload during weaning. Our aim was to measure pendelluft by electrical impedance tomography (EIT) in patients who failed a spontaneous breathing trial (SBT). METHODS: This is an observational study conducted in a general intensive care unit of a tertiary-level teaching hospital. EIT signal was recorded in 20 patients while pressure support (PS) ventilation was progressively reduced from clinical level (baseline) to 2 cmH2O, as in an SBT; four ventral-to-dorsal lung regions of interest were identified for pendelluft measurement. A regional gas movement (> 6 mL) occurring in a direction opposite to the global EIT signal was considered diagnostic for high pendelluft. RESULTS: Eight patients out of 20 (40%) were classified as high-pendelluft; baseline clinical characteristics did not differ between high- and low-pendelluft patients. At PS reduction, pendelluft and EtCO2 increased more in the high-pendelluft group (p < .001 and .011, respectively). The volume of gas subject to pendelluft moved almost completely from the ventral towards the dorsal lung regions, while the opposite movement was minimal (16.3 [10:32.8] vs. 0 [0:1.8] mL, p = .001). In a subgroup of patients, increased pendelluft volumes positively correlated with markers of respiratory distress such as increased respiratory rate, p0.1, and EtCO2. CONCLUSIONS: Occult pendelluft can be measured by EIT, and is frequently present in patients failing an SBT. When present, pendelluft increases with the reduction of ventilator support and is associated with increased EtCO2, suggesting a reduction of the ability to eliminate CO2.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA