Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Preprint en Inglés | medRxiv | ID: ppmedrxiv-20213405

RESUMEN

Pooling multiple swab samples prior to RNA extraction and RT-PCR analysis was proposed as a strategy to reduce costs and increase throughput of SARS-CoV-2 tests. However, reports on practical large-scale group testing for SARS-CoV-2 have been scant. Key open questions concern reduced sensitivity due to sample dilution; the rate of false positives; the actual efficiency (number of tests saved by pooling) and the impact of infection rate in the population on assay performance. Here we report analysis of 133,816 samples collected at April-September 2020, tested by pooling for the presence of SARS-CoV-2. We spared 76% of RNA extraction and RT-PCR tests, despite the reality of frequently changing prevalence rate (0.5%-6%). Surprisingly, we observed pooling efficiency and sensitivity that exceed theoretical predictions, which resulted from non-random distribution of positive samples in pools. Overall, the findings strongly support the use of pooling for efficient large high throughput SARS-CoV-2 testing.

2.
Preprint en Inglés | medRxiv | ID: ppmedrxiv-20201921

RESUMEN

Conducting numerous, rapid, and reliable PCR tests for SARS-CoV-2 is essential for our ability to monitor and control the current COVID-19 pandemic. Here, we tested the sensitivity and efficiency of SARS-CoV-2 detection in clinical samples collected directly into a mix of lysis buffer and RNA preservative, thus inactivating the virus immediately after sampling. We tested 79 COVID-19 patients and 20 healthy controls. We collected two samples (nasopharyngeal swabs) from each participant: one swab was inserted into a test tube with Viral Transport Medium (VTM), following the standard guideline used as the recommended method for sample collection; the other swab was inserted into a lysis buffer supplemented with nucleic acid stabilization mix (coined NSLB). We found that RT-qPCR tests of patients were significantly more sensitive with NSLB sampling, reaching detection threshold 2.1{+/-}0.6 (Mean{+/-}SE) PCR cycles earlier then VTM samples from the same patient. We show that this improvement is most likely since NSLB samples are not diluted in lysis buffer before RNA extraction. Re-extracting RNA from NSLB samples after 72 hours at room temperature did not affect the sensitivity of detection, demonstrating that NSLB allows for long periods of sample preservation without special cooling equipment. We also show that swirling the swab in NSLB and discarding it did not reduce sensitivity compared to retaining the swab in the tube, thus allowing improved automation of COVID-19 tests. Overall, we show that using NSLB instead of VTM can improve the sensitivity, safety, and rapidity of COVID-19 tests at a time most needed.

3.
Preprint en Inglés | medRxiv | ID: ppmedrxiv-20069062

RESUMEN

Testing for active SARS-CoV-2 infection is a fundamental tool in the public health measures taken to control the COVID-19 pandemic. Due to the overwhelming use of SARS-CoV-2 RT-PCR tests worldwide, availability of test kits has become a major bottleneck. Here we demonstrate pooling strategies to perform RNA extraction and RT-PCR in pools, significantly increasing throughput while maintaining clinical sensitivity. We implemented the method in a routine clinical diagnosis setting of asymptomatic populations, and already tested 5,464 individuals for SARS-CoV-2 using 731 RNA extraction and RT-PCR kits. We identified six SARS-CoV-2 positive patients corresponding to 0.11% of the tested population.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA