Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Environ Sci Pollut Res Int ; 28(24): 31195-31206, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33598835

RESUMEN

This study was derived to investigation of BTEX (benzene, toluene, ethylbenzene, xylenes) concentrations in printing and copying centers (PCCs) in Ardabil city of Iran. Fifty-three PCCs were randomly selected from all the 136 number of PCCs and BTEX was sampled form their indoor air. The results showed that the concentration of BTEX in the indoor air PCCs is lower than the OELs (occupational exposure limit) in all cases. The obtained mean concentrations of benzene, toluene, ethylbenzene, and xylene were 93.6±63.2, 150.6±99.2, 34.3±16.8, and 29.5±15.2 µg/m3 respectively. Type of printer, number of printing and copying device, and type of ventilation system had significant influence on the BTEX concentration. The mean inhalation lifetime cancer risk (LTCR) value for benzene and ethylbenzene in the indoor air of the PCCs with LaserJet and inkjet printers was 44.4 × 10-6 and 153.3 × 10-6, and 23.4×10-6 and 54.2× 10-6, respectively, which were higher than EPA (Environmental Protection Agency) and World Health Organization (WHO) recommended limits. The hazard quotient (HQ) of benzene in the indoor air of the PCCs with inkjet printers was >1, which indicates that the non-carcinogenic risks associated with exposure to these compounds are considerable.


Asunto(s)
Contaminantes Atmosféricos , Contaminantes Atmosféricos/análisis , Benceno/análisis , Derivados del Benceno/análisis , Ciudades , Monitoreo del Ambiente , Irán , Impresión Tridimensional , Medición de Riesgo , Tolueno/análisis , Xilenos/análisis
2.
AMB Express ; 10(1): 8, 2020 Jan 14.
Artículo en Inglés | MEDLINE | ID: mdl-31938898

RESUMEN

With increasing concerns about industrial gas contaminants and the growing demand for durable and sustainable technologies, attentions have been gradually shifted to biological air pollution controls. The ability of Pseudomonas putida PTCC 1694 (bacteria) and Pleurotus ostreatus IRAN 1781C (fungus) to treat contaminated gas stream with toluene and its biological degradation was compared under similar operating conditions. For this purpose, a biofilter on the laboratory scale was designed and constructed and the tests were carried out in two stages. The first stage, bacterial testing, lasted 20 days and the second stage, fungal testing, lasted 16 days. Inlet loading rates (IL) for bacterial and fungal biofilters were 21.62 ± 6.04 and 26.24 ± 7.35 g/m3 h respectively. In general, fungal biofilter showed a higher elimination capacity (EC) than bacterial biofilter (18.1 ± 6.98 vs 13.7 ± 4.7 g/m3 h). However, the pressure drop in the fungal biofilter was higher than the bacterial biofilter (1.26 ± 0.3 vs 1 ± 0.3 mm water), which was probably due to the growth of the mycelium. Fungal biofiltration showed a better performance in the removal of toluene from the air stream.

3.
Iranian J Environ Health Sci Eng ; 9(1): 20, 2012 Dec 10.
Artículo en Inglés | MEDLINE | ID: mdl-23369487

RESUMEN

The possible emission of sulfuric acid mists from a laboratory scale, counter-current packed bed tower operated with a caustic scrubbing solution was studied. Acid mists were applied through a local exhaust hood. The emissions from the packed bed tower were monitored in three different categories of gas flow rate as well as three liquid flow rates, while other influencing parameters were kept almost constant. Air sampling and sulfuric acid measurement were carried out iso-kinetically using USEPA method 8. The acid mists were measured by the barium-thorin titration method. According to the results when the gas flow rate increased from 10 L/s to 30 L/s, the average removal efficiency increased significantly (p < 0.001) from 76.8 ± 1.8% to 85.7 ± 1.2%. Analysis of covariance method followed by Tukey post-hoc test of 92 tests did not show a significant change in removal efficiency between liquid flow rates of 1.5, 2.5 and 3.5 L/min (p = 0.811). On the other hand, with fixed pressure loss across the tower, by increasing the liquid/gas (L/G) mass ratio, the average removal efficiency decreased significantly (p = 0.001) from 89.9% at L/G of <2 to 83.1% at L/G of 2-3 and further to 80.2% at L/G of >3, respectively. L/G of 2-3 was recommended for designing purposes of a packed tower for sulfuric acid mists and vapors removal from contaminated air stream.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA