Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros











Intervalo de año de publicación
1.
Arch Endocrinol Metab ; 62(5): 501-505, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30462802

RESUMEN

OBJECTIVE: Magnetic resonance spectroscopy (MRS) is a powerful tool for structural studies of chemical compounds and biomolecules and also documented promising findings as a potential imaging technology in thyroid oncology. This prospective study was to ascertain the clinical significance of 3 Tesla MRS in the evaluation of patients with thyroid nodules (TNs) as an ancillary diagnostic technique for thyroid carcinoma. MATERIALS AND METHODS: Magnetic resonance spectroscopy at 3T at echo- times (TEs) 136 and 270 ms was carried out on 15 patients with total number of 32 TNs larger than 1 cm3, which all were surgically resected. Choline (Chol) to creatine (Cr) ratio was assessed at 136 and 270 TEs on each nodule and a receiver operating characteristic (ROC) curve was used to determine optimal cut-off point. The findings were compared with histopathology of thyroid specimens. RESULTS: There were 23 benign and 9 malignant lesions (7 papillary and 2 follicular thyroid carcinomas). The mean values of Chol/Cr at 136 and 270 TEs was 2.28 ± 3.65 and 1.52 ± 1.67 respectively and the difference between benign and malignant nodules was only significant at 136 TEs. The study revealed that Chol/ Cr ratio cut-off point of 2.5 best correlates with histopathology results (sensitivity = 75%; specificity = 100%; PPV = 100%; NPV= 92%). CONCLUSION: This preliminary study showed that 3T magnetic resonance spectroscopy might be a specific modality for the evaluation of thyroid nodules in differentiation of benign from malignant thyroid tissue. However, a larger series would give much greater confidence that this state-of-the-art technology will worth pursuing in clinical practice.


Asunto(s)
Carcinoma/diagnóstico por imagen , Espectroscopía de Protones por Resonancia Magnética/métodos , Neoplasias de la Tiroides/diagnóstico por imagen , Nódulo Tiroideo/diagnóstico por imagen , Adulto , Colina/análisis , Creatina/análisis , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Valores de Referencia , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Estadísticas no Paramétricas , Adulto Joven
2.
Arch. endocrinol. metab. (Online) ; 62(5): 501-505, Oct. 2018. tab, graf
Artículo en Inglés | LILACS | ID: biblio-983792

RESUMEN

ABSTRACT Objective: Magnetic resonance spectroscopy (MRS) is a powerful tool for structural studies of chemical compounds and biomolecules and also documented promising findings as a potential imaging technology in thyroid oncology. This prospective study was to ascertain the clinical significance of 3 Tesla MRS in the evaluation of patients with thyroid nodules (TNs) as an ancillary diagnostic technique for thyroid carcinoma. Materials and methods: Magnetic resonance spectroscopy at 3T at echo- times (TEs) 136 and 270 ms was carried out on 15 patients with total number of 32 TNs larger than 1 cm3, which all were surgically resected. Choline (Chol) to creatine (Cr) ratio was assessed at 136 and 270 TEs on each nodule and a receiver operating characteristic (ROC) curve was used to determine optimal cut-off point. The findings were compared with histopathology of thyroid specimens. Results: There were 23 benign and 9 malignant lesions (7 papillary and 2 follicular thyroid carcinomas). The mean values of Chol/Cr at 136 and 270 TEs was 2.28 ± 3.65 and 1.52 ± 1.67 respectively and the difference between benign and malignant nodules was only significant at 136 TEs. The study revealed that Chol/ Cr ratio cut-off point of 2.5 best correlates with histopathology results (sensitivity = 75%; specificity = 100%; PPV = 100%; NPV= 92%). Conclusion: This preliminary study showed that 3T magnetic resonance spectroscopy might be a specific modality for the evaluation of thyroid nodules in differentiation of benign from malignant thyroid tissue. However, a larger series would give much greater confidence that this state-of-the-art technology will worth pursuing in clinical practice.


Asunto(s)
Humanos , Masculino , Femenino , Adulto , Persona de Mediana Edad , Adulto Joven , Neoplasias de la Tiroides/diagnóstico por imagen , Carcinoma/diagnóstico por imagen , Nódulo Tiroideo/diagnóstico por imagen , Espectroscopía de Protones por Resonancia Magnética/métodos , Valores de Referencia , Colina/análisis , Estudios Prospectivos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Estadísticas no Paramétricas , Creatina/análisis
3.
Indian J Radiol Imaging ; 28(4): 460-464, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30662211

RESUMEN

BACKGROUND: Preoperative differentiation of benign from malignant thyroid nodules remains a challenge. Aims: This study assessed the accuracy of diffusion-weighted imaging (DWI) for differentiation between benign and malignant thyroid nodules. MATERIALS AND METHODS: Preoperative DWI was performed in patients with thyroid nodule by means of a 3-T scanner magnetic resonance imaging (MRI). Images were obtained at b value of 50, 500, and 1000 mm2/s to draw an ADC (apparent diffusion coefficient) map. Findings were compared with postoperative histopathologic results. Receiver operating characteristic curve was used to assess the accuracy of different cutoff points. RESULTS: Forty-one thyroid nodules (26 benign and 15 malignant) were included in this study. None of static MRI parameters such as signal intensity, heterogeneity, and nodule border was useful to discriminate between benign and malignant lesions. Mean ADC value was (1.94 ± 0.54) × 10-3 mm2/s and (0.89 ± 0.29) × 10-3 mm2/s in benign and malignant nodules, respectively (P-value < 0.005). ADC value cutoff of 1 × 10-3 mm2/s yielded an accuracy, sensitivity, and specificity of 93%, 87%, and 96% to discriminate benign and malignant nodules. CONCLUSION: DWI is highly accurate for discrimination between benign and malignant thyroid nodules.

4.
Korean J Urol ; 56(10): 722-8, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26495074

RESUMEN

PURPOSE: The aim of this study was to compare the penile cuff test (PCT) and standard pressure-flow study (PFS) in patients with bladder outlet obstruction. MATERIALS AND METHODS: A total of 58 male patients with moderate to severe lower urinary tract symptoms (LUTS) were selected. Seven patients were excluded; thus, 51 patients were finally enrolled. Each of the patients underwent a PCT and a subsequent PFS. The sensitivity (SE), specificity (SP), positive predictive value (PPV), negative predictive value (NPV), and likelihood ratio were calculated. Chi-square and Fisher exact test were used to evaluate relationships between PCT results and maximal urine flow (Qmax); a p<0.05 was considered statistically significant. RESULTS: The mean (±standard deviation) age of the study group was 65.5±10.4 years. Overall, by use of the PCT, 24 patients were diagnosed as being obstructed and 27 patients as unobstructed. At the subsequent PFS, 16 of the 24 patients diagnosed as obstructed by the PCT were confirmed to be obstructed, 4 were diagnosed as unobstructed, and the remaining 4 patients appeared equivocal. Of the 27 patients shown to be unobstructed by the PCT, 25 were confirmed to not be obstructed by PFS, with 13 equivocal and 12 unobstructed. Two patients were diagnosed as being obstructed. For detecting obstruction, the PCT showed an SE of 88.9% and an SP of 75.7%. The PPV was 66.7% and the NPV was 93%. CONCLUSIONS: The PCT is a beneficial test for evaluating patients with LUTS. In particular, this instrument has an acceptable ability to reject obstruction caused by benign prostatic hyperplasia.


Asunto(s)
Obstrucción del Cuello de la Vejiga Urinaria/diagnóstico , Anciano , Anciano de 80 o más Años , Humanos , Masculino , Persona de Mediana Edad , Nomogramas , Pene/fisiopatología , Valor Predictivo de las Pruebas , Presión , Sensibilidad y Especificidad , Obstrucción del Cuello de la Vejiga Urinaria/fisiopatología , Micción/fisiología , Urodinámica
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA