Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Speech Lang Hear Res ; 65(3): 1186-1195, 2022 03 08.
Artículo en Inglés | MEDLINE | ID: mdl-35226539

RESUMEN

PURPOSE: The aim of this study was to analyze the association of total leisure noise exposure and hearing threshold shifts over 5 years among adolescents enrolled in the Ohrkan cohort study. METHOD: The Ohrkan cohort of 2,148 students aged 13-19 years was recruited from 2009 to 2011 and followed up 5 years later. Complete baseline and follow-up reports on exposure and outcome were available for 989 participants. Leisure noise exposure was assessed by questionnaires, and clinical audiometric examinations were performed. Two outcomes were defined: occurrence of the Niskar notch pattern and audiometry showing maximum hearing threshold values at 3, 4, and 6 kHz (both ears). Longitudinal analysis using generalized estimating equations was performed. RESULTS: High total leisure noise exposure, defined as an energy equivalent of a 40-hr week of > 85 dBA, was estimated for 32.7% of students at baseline and 63.8% at follow-up. A noise notch was observed in 1.1% of adolescents at baseline and 3.3% at follow-up. At baseline, the maximum measured threshold shift was 55 dB, which increased to 85 dB at the follow-up. Longitudinal analysis did not reveal an association between leisure noise exposure and hearing thresholds. Hearing threshold shifts or noise notches were associated with sex, school type, and time point of measurement. CONCLUSIONS: No relationship was found between leisure noise and hearing thresholds. Male adolescents and those attending secondary general schools, with graduation following completion of ninth or 10th grade, had a greater likelihood of developing hearing threshold shifts. Prevention programs should focus on these risk groups. SUPPLEMENTAL MATERIAL: https://doi.org/10.23641/asha.19233462.


Asunto(s)
Pérdida Auditiva Provocada por Ruido , Adolescente , Adulto , Umbral Auditivo , Estudios de Cohortes , Audición , Pérdida Auditiva Provocada por Ruido/epidemiología , Pérdida Auditiva Provocada por Ruido/prevención & control , Humanos , Actividades Recreativas , Masculino , Ruido/efectos adversos , Adulto Joven
2.
Int J Hyg Environ Health ; 222(2): 249-259, 2019 03.
Artículo en Inglés | MEDLINE | ID: mdl-30497988

RESUMEN

Although exposure to high levels of microbial bioaerosols can be linked to the deterioration of the human respiratory system, precise exposure levels responsible for such effects are still unknown. A previous systematic review concluded that there was not enough information in the studies in humans to derive an exposure-response relationship. Thus, the aim of this systematic review was to derive exposure limits for microbial bioaerosols based on health effects in experimental animal studies. A systematic search was done in MEDLINE (PubMed) for long-term in vivo exposure of the respiratory system via inhalation of a quantified microbial bioaerosol. A total of n = 301 studies were retrieved. Abstract screening using predefined inclusion and exclusion criteria was followed by full-text screening and standardized data extraction of study characteristics and measured outcomes. As a result, four suitable studies were identified where mice or guinea pigs were exposed for 4-12 weeks to a previously described mixture of fungal spores or conidia via inhalation. The number of macrophages, neutrophils, eosinophils and lymphocytes following subchronic exposure has been reported by all included papers and suggested a dose- and time-dependent relationship. Significant inflammation was observed following subacute exposure to Aspergillus fumigatus. However, the outcomes of the studies could not be directly compared due to the large degree of variation and poor description of the exposure conditions. It is our conclusion that more experimental research needs to be done with the specific aim of establishing a No-Observed-Adverse-Effect Level (NOAEL) and a Lowest-Observed-Adverse-Effect Level (LOAEL) for exposure to microbial bioaerosols in ambient air. Expertise of both exposure and outcome assessment should be brought together to enable standardization of experimental animal studies with properly generated aerosols aiming to derive health-based exposure limits.


Asunto(s)
Aerosoles/normas , Aerosoles/toxicidad , Exposición a Riesgos Ambientales/normas , Microbiología del Aire , Animales , Bacterias , Hongos
3.
Noise Health ; 19(91): 263-269, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-29319010

RESUMEN

BACKGROUND: Studies investigating leisure noise effect on extended high frequency hearing are insufficient and they have inconsistent results. The aim of this study was to investigate if extended high-frequency hearing threshold shift is related to audiometric notch, and if total leisure noise exposure is associated with extended high-frequency hearing threshold shift. MATERIALS AND METHODS: A questionnaire of the Ohrkan cohort study was used to collect information on demographics and leisure time activities. Conventional and extended high-frequency audiometry was performed. We did logistic regression between extended high-frequency hearing threshold shift and audiometric notch as well as between total leisure noise exposure and extended high-frequency hearing threshold shift. Potential confounders (sex, school type, and firecrackers) were included. RESULTS: Data from 278 participants (aged 18-23 years, 53.2% female) were analyzed. Associations between hearing threshold shift at 10, 11.2, 12.5, and 14 kHz with audiometric notch were observed with a higher prevalence of threshold shift at the four frequencies, compared to the notch. However, we found no associations between total leisure noise exposure and hearing threshold shift at any extended high frequency. CONCLUSION: This exploratory analysis suggests that while extended high-frequency hearing threshold shifts are not related to total leisure noise exposure, they are strongly associated with audiometric notch. This leads us to further explore the hypothesis that extended high-frequency threshold shift might be indicative of the appearance of audiometric notch at a later time point, which can be investigated in the future follow-ups of the Ohrkan cohort.


Asunto(s)
Audiometría de Tonos Puros/estadística & datos numéricos , Umbral Auditivo/fisiología , Exposición a Riesgos Ambientales/efectos adversos , Actividades Recreativas/psicología , Ruido , Adolescente , Audiometría de Tonos Puros/métodos , Femenino , Alemania , Audición/fisiología , Humanos , Masculino , Encuestas y Cuestionarios , Adulto Joven
4.
Int J Hyg Environ Health ; 218(7): 577-89, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26272513

RESUMEN

Studies suggest adverse health effects following exposure to bioaerosols in the environment and in particular at workplaces. However, there is still a lack of health-related exposure limits based on toxicological or epidemiological studies from environmental health or from the working environment. The aim of this study was to derive health-based exposure limits for bioaerosols that can protect the general population as group "at risk" via environmental exposure using analysis of peer-reviewed studies related to occupational medicine, indoor air and environmental health. The derivation of exposure limits should be conducted by the members of a bioaerosol expert panel according to established toxicological criteria. A systematic review was performed in Medline (PubMed) including studies containing both data on exposure measurements and observed health outcomes. In addition, literature recommended by the experts was considered. A comprehensive search strategy was generated and resulted in a total of n=1569 studies in combination with the literature recommendations. Subsequently, abstracts were screened using defined exclusion criteria yielding a final number of n=44 studies. A standardized extraction sheet was used to combine data on health effects and exposure to different bioaerosols. After full-text screening and extraction according to the defined exclusion criteria n=20 studies were selected all related to occupational exposures comprising the working areas wood processing, farming, waste processing and others. These studies were analyzed in collaboration with the bioaerosol expert network in terms of suitability for derivation of health-related exposure limits. The bioaerosol expert network concluded that none of the analyzed studies provided suitable dose-response relationships for derivation of exposure limits. The main reasons were: (1) lack of studies with valid dose-response data; (2) diversity of employed measuring methods for microorganisms and bioaerosol-emitting facilities; (3) heterogeneity of health effects; (4) insufficient exposure assessment. However, several indicator parameters and exposure concentrations could be identified for different bioaerosol-emitting facilities. Nevertheless, health-related exposure limits are urgently needed especially in approval procedures of facilities like composting plants or livestock farms emitting bioaerosols in the neighbourhood of residents. In the regulatory toxicology framework, it is common to use animal experimental studies for derivation of general exposure limits if appropriate environmental epidemiological studies on harmful substances are lacking. This might be another possibility to obtain health-related exposure limits for specific bioaerosol parameters. Furthermore, we recommend to use suitable measurable outcome parameters related to bioaerosols; to measure bioaerosols according to a protocol representative for exposure pattern and duration at the particular work place; to develop standardized detection methods for indicator parameters; to combine different detection methods to compensate for the limitations of each method; to apply new analysis methods to identify the real risk potential.


Asunto(s)
Microbiología del Aire , Contaminantes Ocupacionales del Aire/efectos adversos , Contaminación del Aire/efectos adversos , Exposición Profesional/efectos adversos , Aerosoles , Contaminantes Ocupacionales del Aire/análisis , Contaminación del Aire/análisis , Salud , Humanos , Exposición Profesional/análisis
5.
Int J Hyg Environ Health ; 217(2-3): 145-54, 2014 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24100053

RESUMEN

Bioaerosols from cooling towers are often suspected to cause community-acquired legionellosis outbreaks. Although Legionella infections can mostly be assigned to the emission sources, uncertainty exists about the release and distribution into the air, the occurrence of the respirable virulent form and the level of the infective concentration. Our study aimed to evaluate studies on legionellosis outbreaks attributed to cooling towers published within the last 11 years by means of a systematic review of the literature. 19 legionellosis outbreaks were identified affecting 12 countries. Recurring events were observed in Spain and Great Britain. In total, 1609 confirmed cases of legionellosis and a case-fatality rate of approximately 6% were reported. Duration of outbreaks was 65 days on average. For diagnosis the urinary antigen test was mainly used. Age, smoking, male sex and underlying diseases (diabetes, immunodeficiency) could be confirmed as risk factors. Smoking and underlying diseases were the most frequent risk factors associated with legionellosis in 11 and 10 of the 19 studies, respectively. The meteorological conditions varied strongly. Several studies reported a temporal association of outbreaks with inadequate maintenance of the cooling systems. A match of clinical and environmental isolates by serotyping and/or molecular subtyping could be confirmed in 84% of outbreaks. Legionella-contaminated cooling towers as environmental trigger, in particular in the neighbourhood of susceptible individuals, can cause severe health problems and even death. To prevent and control Legionella contamination of cooling towers, maintenance actions should focus on low-emission cleaning procedures of cooling towers combined with control measurements of water and air samples. Procedures allowing rapid detection and risk assessment in the case of outbreaks are essential for adequate public health measures. Systematic registration of cooling towers will facilitate the identification of the source of outbreaks and help to shorten their duration.


Asunto(s)
Aire Acondicionado/métodos , Brotes de Enfermedades , Salud Ambiental , Legionella , Legionelosis/epidemiología , Microbiología del Agua , Humanos , Legionella/aislamiento & purificación , Legionelosis/microbiología , España/epidemiología , Reino Unido/epidemiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA