Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Nature ; 2024 Sep 18.
Artículo en Inglés | MEDLINE | ID: mdl-39294379

RESUMEN

Space radiation is a notable hazard for long-duration human spaceflight1. Associated risks include cancer, cataracts, degenerative diseases2 and tissue reactions from large, acute exposures3. Space radiation originates from diverse sources, including galactic cosmic rays4, trapped-particle (Van Allen) belts5 and solar-particle events6. Previous radiation data are from the International Space Station and the Space Shuttle in low-Earth orbit protected by heavy shielding and Earth's magnetic field7,8 and lightly shielded interplanetary robotic probes such as Mars Science Laboratory and Lunar Reconnaissance Orbiter9,10. Limited data from the Apollo missions11-13 and ground measurements with substantial caveats are also available14. Here we report radiation measurements from the heavily shielded Orion spacecraft on the uncrewed Artemis I lunar mission. At differing shielding locations inside the vehicle, a fourfold difference in dose rates was observed during proton-belt passes that are similar to large, reference solar-particle events. Interplanetary cosmic-ray dose equivalent rates in Orion were as much as 60% lower than previous observations9. Furthermore, a change in orientation of the spacecraft during the proton-belt transit resulted in a reduction of radiation dose rates of around 50%. These measurements validate the Orion for future crewed exploration and inform future human spaceflight mission design.

2.
Life Sci Space Res (Amst) ; 39: 52-58, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37945089

RESUMEN

We detect regular particle showers in several compact pixel detectors, distributed over the International Space Station. These showers are caused by high energy galactic cosmic rays, with energies often in the 10 s of TeV or higher. We survey the frequency of these events, their dependence on location on ISS, and their independence of the location of ISS, on its orbit. The Timepix detectors used allow individual particle tracks to be resolved, providing a possibility to perform physical analysis of shower events, which we demonstrate. In terms of radiation dosimetry, these showers indicate certain possible limitations of traditional dosimetric measures, in that (a) the dose measured in small sensor may be less than that received in a larger distribution of matter, such as a human and (b) the spatial and temporal extent of these events represents a regime of poorly documented biological response.


Asunto(s)
Radiación Cósmica , Monitoreo de Radiación , Vuelo Espacial , Humanos , Dosis de Radiación , Nave Espacial , Radiometría
3.
Life Sci Space Res (Amst) ; 39: 59-66, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37945090

RESUMEN

The Hybrid Electronic Radiation Assessor (HERA) system is a Timepix-based ionizing radiation detector built for NASA Exploration-class crewed missions. The HERA performs data analysis on-system and generates telemetry messages for ingestion, display, and relay by the spacecraft. Several iterations of the hardware have been flown aboard the International Space Station as payloads to test system operation and gain experience with the hardware in the space radiation environment. The HERA system and its payload operations are described, and data collected by the various HERA systems are presented.


Asunto(s)
Vuelo Espacial , Nave Espacial , Radiación Ionizante
4.
Life Sci Space Res (Amst) ; 39: 95-105, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37945094

RESUMEN

Monitoring space radiation is of vital importance for risk reduction strategies in human space exploration. Radiation protection programs on Earth and in space rely on personal and area radiation monitoring instruments. Crew worn radiation detectors are crucial for successful crew radiation protection programs since they measure what each crewmember experiences in different shielding configurations within the space habitable volume. The Space Radiation Analysis Group at NASA Johnson Space Center investigated several compact, low power, real-time instruments for personal dosimetry. Following these feasibility studies, the Crew Active Dosimeter (CAD) has been chosen as a replacement for the legacy crew passive radiation detectors. The CAD device, based on direct ion storage technology, was developed by Mirion Dosimetry Services to meet the specified NASA design requirements for the International Space Station (ISS) and Artemis programs. After a successful Technology demonstration on ISS, the CAD has been implemented for ISS Crew operations since 2020. The current paper provides an overview of the CAD development, ISS results and comparison with the ISS Radiation Assessment Detector (RAD) and the Radiation Environment Monitor 2 (REM2) instruments.


Asunto(s)
Radiación Cósmica , Monitoreo de Radiación , Vuelo Espacial , Humanos , Nave Espacial , Dosímetros de Radiación , Radiometría , Monitoreo de Radiación/métodos , Dosis de Radiación
5.
Sci Rep ; 11(1): 5152, 2021 03 04.
Artículo en Inglés | MEDLINE | ID: mdl-33664282

RESUMEN

Opioid overdose related deaths have increased dramatically in recent years. Combating the opioid epidemic requires better understanding of the epidemiology of opioid poisoning (OP). To discover trends and patterns of opioid poisoning and the demographic and regional disparities, we analyzed large scale patient visits data in New York State (NYS). Demographic, spatial, temporal and correlation analyses were performed for all OP patients extracted from the claims data in the New York Statewide Planning and Research Cooperative System (SPARCS) from 2010 to 2016, along with Decennial US Census and American Community Survey zip code level data. 58,481 patients with at least one OP diagnosis and a valid NYS zip code address were included. Main outcome and measures include OP patient counts and rates per 100,000 population, patient level factors (gender, age, race and ethnicity, residential zip code), and zip code level social demographic factors. The results showed that the OP rate increased by 364.6%, and by 741.5% for the age group > 65 years. There were wide disparities among groups by race and ethnicity on rates and age distributions of OP. Heroin and non-heroin based OP rates demonstrated distinct temporal trends as well as major geospatial variation. The findings highlighted strong demographic disparity of OP patients, evolving patterns and substantial geospatial variation.


Asunto(s)
Analgésicos Opioides/efectos adversos , Sobredosis de Droga/epidemiología , Heroína/efectos adversos , Trastornos Relacionados con Opioides/epidemiología , Adolescente , Adulto , Distribución por Edad , Anciano , Sobredosis de Droga/patología , Epidemias , Femenino , Humanos , Masculino , Persona de Mediana Edad , Trastornos Relacionados con Opioides/patología , Estudios Retrospectivos , Adulto Joven
6.
Pacing Clin Electrophysiol ; 39(12): 1394-1403, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-27868213

RESUMEN

BACKGROUND: Characteristics and outcomes of concurrently diagnosed new rapid atrial fibrillation (AF) or atrial flutter (AFL) and new heart failure with reduced left ventricular ejection fraction (LVEF) are not well described. METHODS: A retrospective cohort study of subjects referred for expedited transesophageal echocardiography-guided rhythm-control strategies for concurrent new rapid AF/AFL and new LVEF ≤ 40% diagnosed during the same admission was analyzed. RESULTS: Twenty-five subjects (median age 57 years; 96% male; 96% Caucasian; median CHA2 DS2 -VASc = 2) presented with new AF (n = 18) or AFL (n = 7) with rapid ventricular rate (median 135 beats/min) and new reduced LVEF (median 27%; range, 10-37.5%). Seven (28%) subjects had left atrial appendage thrombi (LAAT) and five (20%) subjects had heavy or binge alcohol use. Baseline characteristics were similar between those with and without LAAT. Thirteen subjects with AF and without LAAT underwent direct-current cardioversion (DCCV) and 10 (77%) had AF recurrence within 90 days. Improvement of long-term LVEF to >40% was comparable for subjects with and without initial LAAT (83% vs 94%; P = 0.46). Three of four subjects who received primary prophylaxis implantable cardioverter-defibrillators improved their LVEF to >35% after sinus rhythm maintenance. The median long-term follow-up time was 3.0 years. CONCLUSIONS: Subjects with concurrently diagnosed new rapid AF/AFL and new reduced LVEF are characterized by a high prevalence of LAAT and significant alcohol use. AF subjects without initial LAAT who underwent DCCV had a high 90-day AF recurrence rate. The presence of LAAT did not have a prognosticative effect on eventual LVEF improvement, which was observed in almost all subjects.


Asunto(s)
Alcoholismo/mortalidad , Fibrilación Atrial/mortalidad , Fibrilación Atrial/prevención & control , Aleteo Atrial/mortalidad , Aleteo Atrial/prevención & control , Disfunción Ventricular Izquierda/mortalidad , Causalidad , Estudios de Cohortes , Comorbilidad , Supervivencia sin Enfermedad , Diagnóstico Precoz , Cardioversión Eléctrica/mortalidad , Cardioversión Eléctrica/estadística & datos numéricos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Pennsylvania/epidemiología , Prevalencia , Pronóstico , Estudios Retrospectivos , Factores de Riesgo , Volumen Sistólico , Tasa de Supervivencia , Resultado del Tratamiento , Disfunción Ventricular Izquierda/prevención & control
7.
J Math Biol ; 70(1-2): 237-63, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24553620

RESUMEN

A partial differential equation model for the three-dimensional current flow in an excitable, unmyelinated axon is considered. Where the axon radius is significantly below a critical value R(crit) (that depends upon intra- and extra-cellular conductivity and ion channel conductance) the resistance of the intracellular space is significantly higher than that of the extracellular space, such that the potential outside the axon is uniformly small whilst the intracellular potential is approximated by the transmembrane potential. In turn, since the current flow is predominantly axial, it can be shown that the transmembrane potential is approximated by a solution to the one-dimensional cable equation. It is noted that the radius of the squid giant axon, investigated by (Hodgkin and Huxley 1952e), lies close to R(crit). This motivates us to apply the three-dimensional model to the squid giant axon and compare the results thus found to those obtained using the cable equation. In the context of the in vitro experiments conducted in (Hodgkin and Huxley 1952e) we find only a small difference between the wave profiles determined using these two different approaches and little difference between the speeds of action potential propagation predicted. This suggests that the cable equation approximation is accurate in this scenario. However when applied to the it in vivo setting, in which the conductivity of the surrounding tissue is considerably lower than that of the axoplasm, there are marked differences in both wave profile and speed of action potential propagation calculated using the two approaches. In particular, the cable equation significantly over predicts the increase in the velocity of propagation as axon radius increases. The consequences of these results are discussed in terms of the evolutionary costs associated with increasing the speed of action potential propagation by increasing axon radius.


Asunto(s)
Axones/fisiología , Modelos Neurológicos , Potenciales de Acción , Algoritmos , Animales , Decapodiformes , Conceptos Matemáticos , Conducción Nerviosa/fisiología , Dinámicas no Lineales , Canales de Potasio/metabolismo , Canales de Sodio/metabolismo
8.
J Forensic Nurs ; 6(3): 121-9, 2010.
Artículo en Inglés | MEDLINE | ID: mdl-21175532

RESUMEN

Previous literature on pornography indicates that pornography use for men at risk for aggression may result in sexually aggressive behavior, but very little research has been reported on juvenile sexual abusers' exposure to pornography. The current study compared pornography exposure between male adolescent sexual abusers (n=283) and male nonsexually offending delinquent youth (n=170). Sexual abusers reported more pre- and post-10 (years of age) exposure to pornography than nonsexual abusers. Yet, for the sexual abusers, exposure is not correlated to the age at which the abusers started abusing, to their reported number of victims, or to sexual offense severity. The pre-10 exposure subscale was not related to the number of children the group sexually abused, and the forceful exposure subscale was not correlated with either arousal to rape or degree of force used by the youth. Finally, exposure was significantly correlated with all of the nonsexual crime scores in the study. Implications for forensic nursing are discussed.


Asunto(s)
Literatura Erótica/psicología , Delincuencia Juvenil , Delitos Sexuales , Adolescente , Factores de Edad , Agresión/psicología , Actitud Frente a la Salud , Estudios de Casos y Controles , Niño , Estudios Transversales , Enfermería Forense , Humanos , Delincuencia Juvenil/psicología , Delincuencia Juvenil/estadística & datos numéricos , Masculino , Modelos Psicológicos , Análisis Multivariante , Factores de Riesgo , Delitos Sexuales/psicología , Delitos Sexuales/estadística & datos numéricos , Medio Social , Estadísticas no Paramétricas , Encuestas y Cuestionarios
9.
Bull Am Coll Surg ; 88(2): 43, 2003 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-23581043
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA