Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Radiology ; 277(3): 741-50, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26098458

RESUMEN

PURPOSE: To evaluate accuracy and interobserver variability with the use of the Prostate Imaging Reporting and Data System (PI-RADS) version 2.0 for detection of prostate cancer at multiparametric magnetic resonance (MR) imaging in a biopsy-naïve patient population. MATERIALS AND METHODS: This retrospective HIPAA-compliant study was approved by the local ethics committee, and written informed consent was obtained from all patients for use of their imaging and histopathologic data in future research studies. In 101 biopsy-naïve patients with elevated prostate-specific antigen levels who underwent multiparametric MR imaging of the prostate and subsequent transrectal ultrasonography (US)-MR imaging fusion-guided biopsy, suspicious lesions detected at multiparametric MR imaging were scored by five readers who were blinded to pathologic results by using to the newly revised PI-RADS and the scoring system developed in-house. Interobserver agreement was evaluated by using κ statistics, and the correlation of pathologic results with each of the two scoring systems was evaluated by using the Kendall τ correlation coefficient. RESULTS: Specimens of 162 lesions in 94 patients were sampled by means of transrectal US-MR imaging fusion biopsy. Results for 87 (54%) lesions were positive for prostate cancer. Kendall τ values with the PI-RADS and the in-house-developed scoring system, respectively, at T2-weighted MR imaging in the peripheral zone were 0.51 and 0.17 and in the transitional zone, 0.45 and -0.11; at diffusion-weighted MR imaging, 0.42 and 0.28; at dynamic contrast material-enhanced MR imaging, 0.23 and 0.24, and overall suspicion scores were 0.42 and 0.49. Median κ scores among all possible pairs of readers for PI-RADS and the in-house-developed scoring system, respectively, for T2-weighted MR images in the peripheral zone were 0.47 and 0.15; transitional zone, 0.37 and 0.07; diffusion-weighted MR imaging, 0.41 and 0.57; dynamic contrast-enhanced MR imaging, 0.48 and 0.41; and overall suspicion scores, 0.46 and 0.55. CONCLUSION: Use of the revised PI-RADS provides moderately reproducible MR imaging scores for detection of clinically relevant disease.


Asunto(s)
Imagen por Resonancia Magnética , Neoplasias de la Próstata/diagnóstico , Adulto , Anciano , Biopsia/métodos , Humanos , Imagen por Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Próstata/patología , Neoplasias de la Próstata/patología
2.
J Endourol ; 28(2): 191-5, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24020496

RESUMEN

OBJECTIVES: To present our experience demonstrating the feasibility of off-clamp laparoscopic partial nephrectomy (LPN) for hilar tumors and evaluate intermediate oncologic and renal functional outcomes. PATIENTS AND METHODS: A retrospective review of LPN cases in nine patients was performed. Hilar lesions were defined as renal cortical tumors in direct physical contact with the renal artery, vein, or both as identified on preoperative imaging and confirmed intraoperatively. Although the renal hilum vasculature was isolated for possible clamping if needed, tumor extirpation was performed off-clamp, eliminating warm ischemia time (WIT). The clinicopathologic parameters, perioperative course, complications, and long-term oncologic and renal functional outcomes were analyzed. RESULTS: Nine patients underwent off-clamp LPN for complex hilar tumors. The mean age was 60.5 years, mean American Society of Anesthesiologists physical classification (ASA) score was 2, and mean BMI was 27.7 kg/m(2). The mean tumor size and volume were 3.2 cm and 35.8 cm(3), respectively. A greater proportion of the tumors (55.6%) were endophytic and mostly of clear cell histology (78%). The mean operative time was 131 minutes, estimated blood loss 250 cc, need for transfusion 0%, and complication rates 22%. No positive margins were present intraoperatively or on final pathology. After a median follow-up of 42.8 months, there was no evidence of clinical or radiographic recurrence in any patient. There was no change in the mean estimated glomerular filtration rate preoperatively and at a median follow-up of 32 months (97.2 mL/minute vs 81.3 mL/minute; p=0.052). CONCLUSION: Complex renal hilar tumors can be successfully managed with laparoscopic nephron-sparing surgery with elimination of WIT with preservation of perioperative, renal functional, and oncologic outcomes.


Asunto(s)
Carcinoma Papilar/cirugía , Carcinoma de Células Renales/cirugía , Neoplasias Renales/cirugía , Laparoscopía , Recurrencia Local de Neoplasia/cirugía , Nefrectomía , Adulto , Anciano , Carcinoma Papilar/patología , Carcinoma de Células Renales/patología , Constricción , Estudios de Factibilidad , Femenino , Estudios de Seguimiento , Tasa de Filtración Glomerular , Humanos , Pruebas de Función Renal , Neoplasias Renales/patología , Masculino , Persona de Mediana Edad , Recurrencia Local de Neoplasia/patología , Tempo Operativo , Complicaciones Posoperatorias , Estudios Retrospectivos , Resultado del Tratamiento , Isquemia Tibia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA