Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Water Res ; 195: 116940, 2021 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-33735627

RESUMEN

Organic micropollutants (MPs) are increasingly detected in water resources, which can be a concern for human health and the aquatic environment. Ultraviolet (UV) radiation based advanced oxidation processes (AOP) such as low-pressure mercury vapor arc lamp UV/H2O2 can be applied to abate these MPs. During UV/H2O2 treatment, MPs are abated primarily by photolysis and reactions with hydroxyl radicals (•OH), which are produced in situ from H2O2 photolysis. Here, a model is presented that calculates the applied UV fluence (Hcalc) and the •OH exposure (CT•OH,calc) from the abatement of two selected MPs, which act as internal probe compounds. Quantification of the UV fluence and hydroxyl radical exposure was generally accurate when a UV susceptible and a UV resistant probe compound were selected, and both were abated at least by 50 %, e.g., iopamidol and 5-methyl-1H-benzotriazole. Based on these key parameters a model was developed to predict the abatement of other MPs. The prediction of abatement was verified in various waters (sand filtrates of rivers Rhine and Wiese, and a tertiary wastewater effluent) and at different scales (laboratory experiments, pilot plant). The accuracy to predict the abatement of other MPs was typically within ±20 % of the respective measured abatement. The model was further assessed for its ability to estimate unknown rate constants for direct photolysis (kUV,MP) and reactions with •OH (k•OH,MP). In most cases, the estimated rate constants agreed well with published values, considering the uncertainty of kinetic data determined in laboratory experiments. A sensitivity analysis revealed that in typical water treatment applications, the precision of kinetic parameters (kUV,MP for UV susceptible and k•OH,MP for UV resistant probe compounds) have the strongest impact on the model's accuracy.


Asunto(s)
Contaminantes Químicos del Agua , Purificación del Agua , Humanos , Peróxido de Hidrógeno , Radical Hidroxilo , Oxidación-Reducción , Fotólisis , Rayos Ultravioleta
2.
Int J Hyg Environ Health ; 218(8): 731-41, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26431869

RESUMEN

Fecal contamination of water resources is a major public health concern in densely populated areas since these water bodies are used for drinking water production or recreational purposes. A main source of this contamination originates from combined sewer overflows (CSOs) in regions with combined sewer systems. Thus, the treatment of CSO discharges is urgent. In this study, we explored whether ozonation or UV irradiation can efficiently reduce pathogenic bacteria, viruses, and protozoan parasites in CSOs. Experiments were carried out in parallel settings at the outflow of a stormwater settling tank in the Ruhr area, Germany. The results showed that both techniques reduce most hygienically relevant bacteria, parasites and viruses. Under the conditions tested, ozonation yielded lower outflow values for the majority of the tested parameters.


Asunto(s)
Agua Potable/microbiología , Ozono , Aguas del Alcantarillado/microbiología , Rayos Ultravioleta , Microbiología del Agua , Purificación del Agua/métodos , Animales , Bacterias , Monitoreo del Ambiente , Heces/microbiología , Alemania , Humanos , Lluvia , Agua , Abastecimiento de Agua
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA