Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Circulation ; 55(3): 519-25, 1977 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-319922

RESUMEN

One hundred and eight patients with initial diastolic blood pressure in the range of 100-124 mm Hg while taking hydrochlorothiazide were assigned randomly and double-blind to hydrochlorothiazide plus either bethanidine or guanethidine. The average reduction of the fifth and sixth months' diastolic blood pressure was 18.4 mm Hg for guanethidine and 13.6 mm Hg for bethanidine (P less than 0.01). The distribution of the individual values was such that 68.8% of guanethidine treated patients achieved a diastolic level below 90 mm Hg, compared to only 45.5% of the bethanidine treated group (P less than 0.025). The degree of orthostatic fall in blood pressure was greater with bethanidine than with guanethidine (P less than 0.05). The diurnal variation of blood pressure was slightly greater with bethanidine than with guanethidine. The results significantly favor guanethidine. This study failed to demonstrate that the shorter action of bethanidine confers significantly better control of blood pressure than the longer action of guanethidine.


Asunto(s)
Betanidina/uso terapéutico , Guanetidina/uso terapéutico , Guanidinas/uso terapéutico , Hipertensión/tratamiento farmacológico , Betanidina/administración & dosificación , Ensayos Clínicos como Asunto , Guanetidina/administración & dosificación , Humanos , Hidroclorotiazida/uso terapéutico , Masculino , Persona de Mediana Edad , Factores de Tiempo
2.
Chest ; 70(1): 80-1, 1976 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-1277940

RESUMEN

Postmortem examination two weeks following implantation of a demand pacemaker with sutureless electrodes demonstrated that (1) the loops of intrapericardial electrode leads indented the myocardium and produced a circumscribed area of subepicardial necrosis, and (2) one of the electrode coils protruded into the right ventricular cavity. The use of extrapericardial electrode leads and left ventricular implantation sites should avoid these problems.


Asunto(s)
Electrodos Implantados/efectos adversos , Lesiones Cardíacas/etiología , Infarto del Miocardio/etiología , Marcapaso Artificial/efectos adversos , Lesiones Cardíacas/patología , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/patología , Miocardio/patología , Necrosis , Pericarditis/etiología , Presión
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA