1.
J Mech Behav Biomed Mater ; 4(7): 1396-411, 2011 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-21783150

RESUMEN

Total knee replacement implants consisting of a Co-29Cr-6Mo alloy femoral component and a Ti-6Al-4V tibial component are the basis for the additive manufacturing of novel solid, mesh, and foam monoliths using electron beam melting (EBM). Ti-6Al-4V solid prototype microstructures were primarily α-phase acicular platelets while the mesh and foam structures were characterized by α(')-martensite with some residual α. The Co-29Cr-6Mo containing 0.22% C formed columnar (directional) Cr(23)C(6) carbides spaced ~2 µm in the build direction, while HIP-annealed Co-Cr alloy exhibited an intrinsic stacking fault microstructure. A log-log plot of relative stiffness versus relative density for Ti-6Al-4V and Co-29Cr-6Mo open-cellular mesh and foams resulted in a fitted line with a nearly ideal slope, n = 2.1. A stress shielding design graph constructed from these data permitted mesh and foam implant prototypes to be fabricated for compatible bone stiffness.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Materiales Biocompatibles/química , Electrones , Fenómenos Mecánicos , Prótesis e Implantes , Diseño de Prótesis/métodos , Aleaciones/química , Módulo de Elasticidad , Microscopía Electrónica de Rastreo , Modelos Moleculares , Conformación Molecular , Fenómenos Ópticos , Programas Informáticos , Difracción de Rayos X
2.
Nanotechnology ; 21(36): 365703, 2010 Sep 10.
Artículo en Inglés | MEDLINE | ID: mdl-20699488

RESUMEN

Using ac-susceptibility, dc-magnetization, and transmission electron microscopy, we have investigated the magnetic behavior of Mn(3)O(4) nanoparticle ensembles at temperatures below the paramagnetic-to-ferrimagnetic transition of the title material (T(N) approximately equal 41 K). Our data show no evidence of the complex magnetic ordering exhibited by bulk Mn(3)O(4), or of a magnetic behavior around T(N) that has a dynamic (relaxation) origin. Instead, we find a low-temperature (at approximately 11 K) magnetic anomaly that manifests itself as a peak in the out-of-phase component of the ac-susceptibility. Analysis of the frequency and average-particle-size dependence of the peak temperature demonstrates that this behavior is due to the onset of superparamagnetic relaxation, and not to a previously hinted at spin-glass-like transition. Indeed, the relative peak temperature variation per frequency decade DeltaT/TDeltalog(f) is 0.11, an order of magnitude larger than the value expected for collective spin freezing, but within the range of values observed for superparamagnetic blocking. Furthermore, attempts to fit the frequency f/observation time tau = 1/2pif dependence of the peak temperature by a power law led to parameter values unexpected for a spin-glass transition. On the other hand, a Vogel-Fulcher law tau = tau(0)exp[E(B)/k(B)(T - T(0))]-where E(B) is the energy barrier to magnetization reversal, k(B) is the Boltzmann constant, tau(0) and T(0) are constants related to the attempt frequency and the interparticle interaction strength-correctly describes the peak shift and yields values consistent with the superparamagnetic behavior of a slightly interacting system of nanoparticles. In addition, the peak temperature T is sensitive to minute changes in the average particle size (D), and scales as (T - T(0) is proportional to(D)3, another signature of superparamagnetic relaxation.

3.
Philos Trans A Math Phys Eng Sci ; 368(1917): 1999-2032, 2010 Apr 28.
Artículo en Inglés | MEDLINE | ID: mdl-20308113

RESUMEN

In this paper, we examine prospects for the manufacture of patient-specific biomedical implants replacing hard tissues (bone), particularly knee and hip stems and large bone (femoral) intramedullary rods, using additive manufacturing (AM) by electron beam melting (EBM). Of particular interest is the fabrication of complex functional (biocompatible) mesh arrays. Mesh elements or unit cells can be divided into different regions in order to use different cell designs in different areas of the component to produce various or continually varying (functionally graded) mesh densities. Numerous design elements have been used to fabricate prototypes by AM using EBM of Ti-6Al-4V powders, where the densities have been compared with the elastic (Young) moduli determined by resonant frequency and damping analysis. Density optimization at the bone-implant interface can allow for bone ingrowth and cementless implant components. Computerized tomography (CT) scans of metal (aluminium alloy) foam have also allowed for the building of Ti-6Al-4V foams by embedding the digital-layered scans in computer-aided design or software models for EBM. Variations in mesh complexity and especially strut (or truss) dimensions alter the cooling and solidification rate, which alters the alpha-phase (hexagonal close-packed) microstructure by creating mixtures of alpha/alpha' (martensite) observed by optical and electron metallography. Microindentation hardness measurements are characteristic of these microstructures and microstructure mixtures (alpha/alpha') and sizes.


Asunto(s)
Materiales Biocompatibles/química , Equipos y Suministros , Aleaciones , Fenómenos Biomecánicos , Ingeniería Biomédica , Sustitutos de Huesos/metabolismo , Huesos/metabolismo , Diseño de Equipo , Humanos , Materiales Manufacturados , Ensayo de Materiales , Microscopía Electrónica de Transmisión/métodos , Conformación Molecular , Diseño de Prótesis , Titanio/química , Tomografía Computarizada por Rayos X/métodos
4.
J Mech Behav Biomed Mater ; 2(1): 20-32, 2009 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-19627804

RESUMEN

The microstructure and mechanical behavior of simple product geometries produced by layered manufacturing using the electron beam melting (EBM) process and the selective laser melting (SLM) process are compared with those characteristic of conventional wrought and cast products of Ti-6Al-4V. Microstructures are characterized utilizing optical metallography (OM), scanning electron microscopy (SEM) and transmission electron microscopy (TEM), and included alpha (hcp), beta (bcc) and alpha(') (hcp) martensite phase regimes which give rise to hardness variations ranging from HRC 37 to 57 and tensile strengths ranging from 0.9 to 1.45 GPa. The advantages and disadvantages of layered manufacturing utilizing initial powders in custom building of biomedical components by EBM and SLM in contrast to conventional manufacturing from Ti-6Al-4V wrought bar stock are discussed.


Asunto(s)
Ingeniería Biomédica , Materiales Manufacturados , Fenómenos Mecánicos , Titanio/química , Aleaciones , Factores de Tiempo