Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Int J Ophthalmol ; 17(8): 1437-1446, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39156774

RESUMEN

AIM: To assess and compare the variations and agreements across different ocular biometric parameters using swept-source optical coherence tomography (SS-OCT) and Scheimpflug tomography in patients diagnosed with cataract. METHODS: This prospective case series was conducted at Tianjin Medical University Eye Hospital. In total, 212 eyes from 212 patients scheduled for phacoemulsification were included. Eyes were evaluated preoperatively using two SS-OCT devices (IOLMaster700 and CASIA2) and Scheimpflug tomography (Pentacam). Central corneal thickness (CCT), anterior chamber depth (ACD), aqueous depth (AQD), white-to-white distance (WTW), flat simulated keratometry (Kf), steep simulated keratometry (Ks), mean keratometry (Km), and total corneal keratometry (TKm) were measured. Intraclass correlation coefficient (ICC), 95% confidence intervals (CI) and limits of agreement (LoA) widths were conducted to assess differences and correlations between devices. RESULTS: All parameters, except for Ks, were significantly different. Pairwise comparison revealed no significant differences between keratometry obtained by IOLMaster 700 and Pentacam. LoA widths of all paired comparisons for Ks were >0.80 D. Except for WTW between IOLMaster 700 and CASIA2 and between CASIA2 and Pentacam, other Pearson's coefficients between devices showed a strong correlation (all r>0.95). The ICC of WTW (ICC=0.438, 95%CI 0.167-0.625) showed poor reliability. The reliability of CCT, ACD, and AQD was excellent (all ICC>0.95), whereas that of TKm was good (ICC=0.827, 95%CI 0.221-0.939). A significant linear correlation was also observed among devices. CONCLUSION: The ocular parameters derived from the use of IOLMaster700, CASIA2, and Pentacam exhibit significant discrepancies; as such, measurements from these devices should not be deemed as interchangeable.

2.
Phytochem Anal ; 2024 May 22.
Artículo en Inglés | MEDLINE | ID: mdl-38777368

RESUMEN

INTRODUCTION: Qi-Fu-Yin has been used to treat Alzheimer's disease (AD) in China. Oxidative stress has been recognized as a factor in AD progress. To date, there is no quality control method to ensure batch-to-batch consistency of Qi-Fu-Yin, and the potential antioxidant compounds in Qi-Fu-Yin remain uncertain. OBJECTIVES: The aim of this study is to identify the potential antioxidant compounds of Qi-Fu-Yin and establish quality control standards for Qi-Fu-Yin. METHODS: High-performance liquid chromatography was used to establish and quantify the fingerprints of Qi-Fu-Yin from various batches. Ultrahigh-performance liquid chromatography coupled with quadrupole time-of-flight tandem mass spectrometry (UHPLC-Q-TOF/MS) was used to identify the common peaks. Bivariate correlation analysis, partial least squares regression analysis, and gray correlation analysis were used to establish the spectrum-effect relationship. RESULTS: Forty-nine common peaks were determined through the establishment of fingerprints. Among them, 35 common peaks were preliminarily characterized. The multiple statistical correlation analysis methods identified six compounds as potential antioxidant constituents of Qi-Fu-Yin, and their antioxidant activities were validated in vitro. All six antioxidant compounds derived from two herbs. Therefore, three chemical index compounds derived from other three herbs were added to the quantitative analysis, while for two herbs, no peaks could be included. Eventually, six antioxidant constituents and three index compounds were quantitatively determined to provide a relatively comprehensive quality control for Qi-Fu-Yin. CONCLUSIONS: The study elucidated the antioxidant substance basis of Qi-Fu-Yin and provided a relatively comprehensive approach for the assay of Qi-Fu-Yin, which is a promising advance in the quality control of Qi-Fu-Yin.

4.
Mol Genet Genomic Med ; 12(1): e2345, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38146894

RESUMEN

PURPOSE: Norrie disease (ND) is a rare X-linked recessive disorder characteristic of early childhood blindness. While several mutations in the NDP gene have been reported as causative for ND, the genetic etiology remains unknown for many patients. This study aims to describe a novel mutation and explore the clinical manifestations in a Chinese family with two affected males. METHODS: Exome sequencing (ES) was employed to identify the causative gene in a four-generation pedigree. Sanger sequencing was subsequently utilized to validate the mutation detected by ES in additional family members. Ophthalmologic examination and diagnostic imaging relevant to ND were conducted. RESULTS: The proband (IV:2), an 8-month-old male infant, presented with binocular retinal detachment. DNA sequencing revealed a novel heterozygous missense mutation (c.174G>C) within the NDP gene in the proband. This mutation affected highly conserved residues and was predicted to disrupt the normal protein structure. Furthermore, the variant co-segregated with the disease phenotypes within the family. CONCLUSIONS: Our findings identified a novel missense mutation in the NDP gene associated with Norrie disease in China, expanding the mutation spectrum associated with ND. This discovery holds diagnostic, prognostic, and genetic counseling implications for affected individuals.


Asunto(s)
Enfermedades Genéticas Ligadas al Cromosoma X , Enfermedades del Sistema Nervioso , Degeneración Retiniana , Espasmos Infantiles , Lactante , Humanos , Masculino , Preescolar , Linaje , Degeneración Retiniana/genética , Ceguera/genética , Ceguera/diagnóstico , Mutación , Proteínas del Ojo/genética , Proteínas del Tejido Nervioso/genética
5.
Graefes Arch Clin Exp Ophthalmol ; 262(5): 1567-1578, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38150029

RESUMEN

PURPOSE: To assess the differences and similarities in the corneal curvature obtained by two swept-source optical coherence tomography (SS-OCT) devices, Scheimpflug imaging system and one ray tracing aberrometer in patients with cataracts. Moreover, this study aimed to compare the differences in posterior corneal (PK), total corneal (TK) and true net power (TNP) measurements among the IOLMaster 700, CASIA2, and Pentacam. METHODS: A total of 200 eyes of 200 patients (116 female, 58%) were enrolled in this study, with a mean age of 65.9 ± 9.5 years. The flattest (Kf), steepest (Ks), and mean cornal powers (Km), J0, and J45 were obtained using two SS-OCT-based biometric devices, one rotating camera system and one ray-tracing aberrometer. The PK, TK and TNP values were also measured using these devices. To evaluate the differences and similarities between the devicves, the Friedman test, Pearson correlation coefficient (r), intraclass coefficient correlation (ICC) and Bland‒Altman plots with 95% limits of agreement (LoA) were used, and boxplots and stacked histograms were generated to describe the distributions of the data. RESULTS: There were no significant differences between the IOLMaster 700 and Pentacam for any of the keratometry values. Additionally, there were no significant differences between the IOLMaster 700 and iTrace in evaluating J0 and J45. Bland‒Altman plots revealed relatively wide LoA widths, almost larger than 1 diopter for the keratometry values and almost larger than 0.5 diopter for J0 and J45 values among the four devices. In terms of PK and TK values, significant differences and low ICCs were found among the three devices. CONCLUSIONS: Although strong correlations and good agreement were found among the IOLMaster700, CASIA2, Pentacam and iTrace for Kf, Ks, Km and J0, J45, it seems that the measurements should not be used interchangeably because of the wide LoA widths and the presence of significant differences among the devices. Similarly, due to significant differences and low ICCs, the PK, TK and TNP values obtained by IOLMaster 700, CASIA2, and Pentacam should not be used interchangeably.


Asunto(s)
Catarata , Tomografía de Coherencia Óptica , Humanos , Femenino , Persona de Mediana Edad , Anciano , Tomografía de Coherencia Óptica/métodos , Estudios Prospectivos , Reproducibilidad de los Resultados , Córnea , Catarata/diagnóstico , Biometría , Topografía de la Córnea/métodos
6.
Cell Biol Int ; 45(8): 1757-1767, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-33851769

RESUMEN

Circular RNAs (circRNAs) play important roles in the pathogenesis of age-related cataract (ARC). CircRNA zinc finger protein 292 (circZNF292, hsa_circ_0004058) is downregulated in ARC lens capsules. Here, we focused on its precise roles in oxidative stress underlying the pathogenesis of ARC. CircZNF292, microRNA (miR)-222-3p, and E2F transcription factor 3 (E2F3) were quantified by quantitative real-time polymerase chain reaction or western blot. Cell viability was assessed by the cell counting kit-8 assay. Cell cycle distribution and apoptosis were detected by flow cytometry. The activities of superoxide dismutase, catalase, and malondialdehyde were measured using the corresponding assay kit. Targeted correlations among circZNF292, miR-222-3p, and E2F3 were verified by the dual-luciferase reporter, RNA immunoprecipitation and RNA pull-down assays. Our data showed that circZNF292 was downregulated in ARC tissues and H2 O2 -treated human lens epithelial B3 (HLE-B3) cells. Increased expression of circZNF292 alleviated H2 O2 -induced cell viability suppression, apoptosis promotion, and oxidative stress enhancement. Mechanistically, circZNF292 directly targeted miR-222-3p, and circZNF292 regulated E2F3 expression through miR-222-3p. MiR-222-3p was a functional mediator of circZNF292 in modulating H2 O2 -induced injury in HLE-B3 cells. Furthermore, reduced level of miR-222-3p ameliorated H2 O2 -induced HLE-B3 cell damage by upregulating E2F3. Our present study demonstrated that increased expression of circZNF292 ameliorated H2 O2 -induced injury in HLE-B3 cells at least in part through the miR-222-3p/E2F3 axis, highlighting a novel insight into the involvement of circRNAs in the pathogenesis of ARC.


Asunto(s)
Proteínas Portadoras/biosíntesis , Factor de Transcripción E2F3/biosíntesis , Células Epiteliales/metabolismo , Peróxido de Hidrógeno/toxicidad , Cristalino/metabolismo , MicroARNs/biosíntesis , Proteínas del Tejido Nervioso/biosíntesis , Anciano , Línea Celular , Relación Dosis-Respuesta a Droga , Células Epiteliales/efectos de los fármacos , Femenino , Humanos , Cristalino/efectos de los fármacos , Cristalino/lesiones , Masculino , Persona de Mediana Edad , ARN Circular/biosíntesis
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA