Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Hazard Mater ; 477: 135398, 2024 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-39096639

RESUMEN

Arsenic contamination in environmental water sources poses a significant threat to human health, necessitating the development of sensitive and accessible detection methods. This study presents a multidimensional optimization of a bacterial biosensor for the susceptible and deoxyviolacein (DV)-based visual detection of arsenic. The research involved screening six different arsenic resistance (ars) operons and optimizing the genetic circuit to minimize background noise. Introducing an arsenic-specific transport channel enhanced the sensor's sensitivity to 1 nM with a quantitative range from 0.036 to 1.171 µM. The pigment-based biosensor offers a simple colorimetric approach for arsenic detection without complex instrumentation. The preferred biosensor demonstrated characteristics of anti-chelating agent interference, consistently quantified As(III) concentrations ranging from 0.036 to 1.171 µM covering the World Health Organization (WHO) drinking water limit. Innovatively, it effectively detects arsenic in seawater within a linear regression range of 0.071 to 1.125 µM. The biosensor's selectivity for arsenic was confirmed, with minimal cross-response to group 15 metals. Our naked-eye biosensor offers a novel approach for the rapid, on-site detection of arsenic in various water sources. Its simplicity, cost-effectiveness, and versatility make it a valuable tool for environmental monitoring and public health initiatives.


Asunto(s)
Arsénico , Técnicas Biosensibles , Contaminantes Químicos del Agua , Arsénico/análisis , Técnicas Biosensibles/métodos , Contaminantes Químicos del Agua/análisis , Monitoreo del Ambiente/métodos , Colorimetría/métodos , Agua de Mar/análisis , Agua de Mar/química
2.
ACS Omega ; 9(31): 33868-33881, 2024 Aug 06.
Artículo en Inglés | MEDLINE | ID: mdl-39130558

RESUMEN

Fermentative production of natural colorants using microbial strains has emerged as a cost-effective and sustainable alternative to chemical synthesis. Visual pigments are used as signal outputs in colorimetric bacterial biosensors, a promising method for monitoring environmental pollutants. In this study, we engineered four self-sufficient indigo-forming enzymes, including HbpAv, bFMO, cFMO, and rFPMO, in a model bacterium E. coli. TrxA-bFMO was chosen for its strong ability to produce indigo under T7 lac and mer promoters' regulation. The choice of bacterial hosts, the supplementation of substrate l-tryptophan, and ventilation were crucial factors affecting indigo production. The indigo reporter validated the biosensors for Hg(II), Pb(II), As(III), and Cd(II). The biosensors reported Hg(II) as low as 14.1 nM, Pb(II) as low as 1.5 nM, and As(III) as low as 4.5 nM but increased to 25 µM for Cd(II). The detection ranges for Hg(II), Pb(II), As(III), and Cd(II) were quantified from 14.1 to 225 nM, 1.5 to 24.4 nM, 4.5 to 73.2 nM, and 25 to 200 µM, respectively. The sensitivity, responsive concentration range, and selectivity are comparable to ß-galactosidase and luciferase reporter enzymes. This study suggests that engineered enzymes for indigo production have great potential for green chemical synthesis. Additionally, heterologous biosynthesis of indigo production can lead to the development of novel, low-cost, and mini-equipment bacterial biosensors with zero background noise for visual monitoring of pollutant heavy metals.

3.
Front Microbiol ; 14: 1218933, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37577420

RESUMEN

With the rapid development of synthetic biology, various whole-cell biosensors have been designed as valuable biological devices for the selective and sensitive detection of toxic heavy metals in environmental water. However, most proposed biosensors are based on fluorescent and bioluminescent signals invisible to the naked eye. The development of visible pigment-based biosensors can address this issue. The pbr operon from Klebsiella pneumoniae is selectively induced by bioavailable Pb(II). In the present study, the proviolacein biosynthetic gene cluster was transcriptionally fused to the pbr Pb(II) responsive element and introduced into Escherichia coli. The resultant biosensor responded to Pb(II) in a time- and dose-dependent manner. After a 5-h incubation with Pb(II), the brown pigment was produced, which could be extracted into n-butanol. Extra hydrogen peroxide treatment during n-butanol extract resulted in the generation of a stable green pigment. An increased brown signal was observed upon exposure to lead concentrations above 2.93 nM, and a linear regression was fitted from 2.93 to 3,000 nM. Extra oxidation significantly decreased the difference between parallel groups. The green signal responded to as low as 0.183 nM Pb(II), and a non-linear regression was fitted in a wide concentration range from 0.183 to 3,000 nM. The specific response toward Pb(II) was not interfered with by various metals except for Cd(II) and Hg(II). The PV-based biosensor was validated in monitoring bioaccessible Pb(II) spiked into environmental water. The complex matrices did not influence the regression relationship between spiked Pb(II) and the dual-color signals. Direct reading with the naked eye and colorimetric quantification enable the PV-based biosensor to be a dual-color and low-cost bioindicator for pollutant heavy metal.

4.
Sci Rep ; 12(1): 6898, 2022 04 27.
Artículo en Inglés | MEDLINE | ID: mdl-35477977

RESUMEN

Cadmium (Cd) contamination in water and soil is considered an environmental pollutant. Food crops can absorb and accumulate bioavailable Cd. Continuous monitoring of Cd levels in the environment can minimize exposure and harm to humans. Visual pigments have been demonstrated to have great potential in the development of minimal-equipment biosensors. In the present study, a metabolically engineered bacterium was employed to produce blue-purple pigment violacein responsive to toxic Cd(II). The high stability of the bisindole pigment contributed to determining the violacein at wavelengths of 578 nm. Visual and quantifiable signals could be captured after a 1.5-h Cd(II) exposure. This novel biosensor showed significantly stronger responses to Cd(II) than to other heavy metals including Pb(II), Zn(II), and Hg(II). A significant increase in pigment signal was found to respond to as low as 0.049 µM Cd(II). The naked eye can detect the color change when violacein-based biosensor is exposed to 25 µM Cd(II). A high-throughput method for rapid determination of soluble Cd(II) in environmental water was developed using a colorimetric microplate.


Asunto(s)
Técnicas Biosensibles , Contaminantes Ambientales , Metales Pesados , Técnicas Biosensibles/métodos , Cadmio/toxicidad , Contaminantes Ambientales/toxicidad , Humanos , Agua
5.
Occup Environ Med ; 79(4): 253-258, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-34969777

RESUMEN

BACKGROUND: Although the therapeutic effect of antineoplastic drugs is incontestable, these agents can also potentially act as carcinogens, mutagens and/or teratogens in people. The aim of this study was to assess the effect of occupational exposure to antineoplastic drugs on DNA damage, assessed by the comet assay and cytokinesis-block micronucleus (CBMN) assay, in nurses. METHODS: The cross-sectional study enrolled 305 nursing staff members from 7 public hospitals in Shenzhen who handled antineoplastic drugs, and 150 healthy nursing staff members who were not exposed to antineoplastic drugs as the control group. DNA damage was assessed by the comet and CBMN assay. Multiple linear regressions and logistic regressions models were used to analyse the effect of occupational exposure to antineoplastic drugs on DNA damage. RESULTS: After adjustment for confounding factors, compared with non-exposure to antineoplastic drugs, exposure to antineoplastic drugs was positively related to tail moment, olive moment, tail length and tail DNA per cent, and adjusted ß or OR (95% CI) was 0.17 (0.08 to 0.26), 0.18 (0.10 to 0.27), 1.03 (0.47 to 1.60) and 1.16 (1.04 to 1.29) (all p<0.05). Moreover, similar significant relationships were observed for the biomarkers of the CBMN assay. Additionally, other than age, there was no interaction between antineoplastic drug exposure and other variables for the levels of biomarkers of the CBMN assay and the comet assay. CONCLUSIONS: The present results showed that exposure to antineoplastic drugs was positively related to the risk of DNA damage in nurses. The results imply that occupational exposure to antineoplastic agents is an important global public health problem that requires urgent attention.


Asunto(s)
Antineoplásicos , Exposición Profesional , Antineoplásicos/efectos adversos , Biomarcadores , Ensayo Cometa , Estudios Transversales , Daño del ADN , Humanos , Linfocitos , Pruebas de Micronúcleos/métodos , Exposición Profesional/efectos adversos , Exposición Profesional/análisis
6.
PLoS One ; 16(5): e0252190, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34038487

RESUMEN

Mercury exists naturally and mainly as a man-made pollutant in the environment, where it exerts adverse effects on local ecosystems and living organisms. It is important to develop an appropriate synthetic biological device that recognizes, detects and removes the bioavailable fraction of environmental mercury. Both single-signal and double-signal output mercury biosensors were assembled using a natural mer operon as a template. Selectivity and sensitivity of whole-cell biosensors based on artificial mer operons were determined. Three whole-cell biosensors were highly stable at very high concentrations of mercuric chloride, and could detect bioavailable Hg(II) in the concentration range of 6.25-200 µM HgCl2. A novel Hg(II) bioadsorption coupled with biosensing artificial mer operon was assembled. This would allow Hg(II)-induced Hg(II) binding protein cell surface display and green fluorescence emission to be achieved simultaneously while retaining the linear relationship between fluorescent signal and Hg(II) exposure concentration. The present study provides an innovative way to simultaneously detect, quantify, and remove bioavailable heavy metal ions using an artificially reconstructed heavy metal resistance operon.


Asunto(s)
Técnicas Biosensibles , Escherichia coli/genética , Escherichia coli/metabolismo , Mercurio/metabolismo , Operón/genética , Ecosistema , Cloruro de Mercurio/farmacología
7.
PLoS One ; 15(1): e0228456, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-31999769

RESUMEN

The combination of a fluorescent reporter and enzymatic reporter provides a flexible and versatile way for the study of diverse biological processes, such as the detection of transcription and translation. Thus, there is an urgent need to develop this novel bifunctional reporter system. This study reports the design, construction, and validation of a new dicistronic mCherry-lacZα reporter system by artificial lac operon and pbr operon models in lacZM15-producing E. coli. It allows two reporter genes to be co-transcribed into a dicistronic mRNA strand, followed by coupled expression of mCherry and lacZα. In artificial lac operons, expression of the downstream lacZα was demonstrated to be positively related to expression of the upstream ORF. In artificial pbr operons, compared with the insertion of downstream full-length lacZ, the insertion of downstream lacZα exerted a slight effect on the response from the upstream mCherry. Furthermore, the downstream lacZα reporter showed stronger response to Pb(II) than the downstream full-length lacZ. Importantly, the response sensitivity of downstream lacZα was still higher than that of upstream mCherry in a dual RFP-lacZα reporter construct. The highly efficient expression profile of the reporter lacZα peptide makes it a preferred downstream reporter in polycistronic constructs. This novel bifunctional reporter system offers a robust tool for biological studies.


Asunto(s)
Escherichia coli/genética , Genes Reporteros , Plomo/análisis , Técnicas Biosensibles , Expresión Génica , Genes , Operón Lac , Proteínas Luminiscentes/genética , ARN Mensajero/metabolismo , Proteína Fluorescente Roja
8.
RSC Adv ; 10(47): 28106-28113, 2020 Jul 27.
Artículo en Inglés | MEDLINE | ID: mdl-35519119

RESUMEN

Environmental risks continue to grow due to heavy metal contamination caused by anthropogenic activities. Accumulation of harmful quantities of lead poses a threat to aquatic organisms, plants, and human beings. Whole-cell biosensors, which can proliferate independently, can detect the bioavailable fraction to assess the effect of target heavy metal on the environmental ecosystem. In this study, the biosynthesis pathway of violacein was heterogeneously constructed under the control of the T7 lac promoter in E. coli. A dose-response relationship existed between the inducer and the production of violacein. The biosynthesis pathway of violacein was finally engineered under the regulation of Pb(ii)-dependent metalloregulator PbrR to assemble Pb(ii)-inducible whole-cell biosensor. It permitted specific biosensing of Pb(ii) with extraordinary selectivity, and could resist the interferences from various metal ions. Color change by the intracellular accumulation of violacein could be recognized with the naked eye directly with high concentration of lead exposure, and quantified by determining the absorbance at 490 nm after butanol extraction. A good linear range for Pb(ii) concentrations of 0.1875-1.5 µM was obtained. The novel pigment-based whole-cell biosensor could detect concentrations as low as 0.1875 µM Pb(ii) based on in vitro quantification of violacein extracted by butanol, which is significantly lower than reported fluorescent protein-based PbrR-regulated biosensors based on direct measurement of whole cell fluorescence. These results indicate that genetically controlled violacein biosynthesis can enable a sensitive, visual, and qualitative biosensor for monitoring the presence of bioavailable Pb(ii) in lead-contaminated water.

9.
Zhongguo Shi Yan Xue Ye Xue Za Zhi ; 26(6): 1765-1771, 2018 Dec.
Artículo en Chino | MEDLINE | ID: mdl-30501718

RESUMEN

OBJECTIVE: To investigate the effects of different stimultors (PHA, PMA and IL-2) and culture systems (PBMC and whole blood) on the proliferation of human peripheral blood lymphocyte subsets, so as to provide the experimental basis for selecting the appropriate system according to the experimental purposes. METHODS: A total of 10 ml serum samples were collected from healthy volunteers (n=6). The 300 µl whole blood was directly used to detect lymphocyte subsets by flow cytometry. The 400 µl whole blood were inoculated respectively with 3 different stimulators at 37℃ and 5% CO2 for 60 h; Three different stimulators were also added to the PBMC which were isolated from 2 ml whole blood. Then the proliferation ability of lymphocyte subsets was analyzed by flow cytometry. RESULTS: After the PBMC were stimulated with PHA, CD4-CD8-CD3+ lymphocytes were the most subset; The proportion of CD3+CD4+ T lymphocytes and CD3-CD19+ B lymphocytes decreased after being stimulated by PMA (P<0.01, P<0.05); the lymphocyte subset ratio had no significant change after being stimulated by IL-2. After the whole blood system was stimulated with PHA, the CD4+/CD8+ T lymphoblasts were main subsets, the counts of B lymphocytes and NK cells were reduced; after being stimulated with PMA, the number of CD8+CD3+ T lymphoblast and CD4-CD8-T lymphocytes increased, the B/NK cells were not distinguished with the surface markers; after the whole blood system was stimulated with IL-2, the proportion of NK cells significantly increased (P<0.05). CONCLUSION: Lymphocyte proliferation stimulated by PMA is the fastest, while the effect of IL-2 on the lymphocyte subset proportion stimulated by IL-2 is the minimal. After being stimulated by PHA the division cycles of lymphocyte are the most.


Asunto(s)
Proliferación Celular , Subgrupos Linfocitarios , Citometría de Flujo , Humanos , Células Asesinas Naturales , Activación de Linfocitos , Recuento de Linfocitos
10.
Sci Rep ; 8(1): 5685, 2018 04 09.
Artículo en Inglés | MEDLINE | ID: mdl-29632327

RESUMEN

Human exposure to lead mainly occurs by ingestion of contaminated food, water and soil. Blocking lead uptake in the gastrointestinal tract is a novel prevention strategy. Whole-cell biosorbent for lead was constructed with PbrR genetically engineered on the cell surface of Escherichia coli (E. coli), a predominant strain among intestinal microflora, using lipoprotein (Lpp)-OmpA as the anchoring protein. In vitro, the PbrR displayed cells had an enhanced ability for immobilizing toxic lead(II) ions from the external media at both acidic and neutral pH, and exhibited a higher specific adsorption for lead compared to other physiological two valence metal ions. In vivo, the persistence of recombinant E. coli in the murine intestinal tract and the integrity of surface displayed PbrR were confirmed. In addition, oral administration of surface-engineered E. coli was safe in mice, in which the concentrations of physiological metal ions in blood were not affected. More importantly, lead associated with PbrR-displayed E. coli was demonstrated to be less bioavailable in the experimental mouse model with exposure to oral lead. This is reflected by significantly lower blood and femur lead concentrations in PbrR-displayed E. coli groups compared to the control. These results open up the possibility for the removal of toxic metal ions in vivo using engineered microorganisms as adsorbents.


Asunto(s)
Proteínas Bacterianas/genética , Proteínas Bacterianas/metabolismo , Escherichia coli/genética , Ingeniería Genética/métodos , Plomo/análisis , Animales , Proteínas de la Membrana Bacteriana Externa/metabolismo , Disponibilidad Biológica , Biotransformación , Membrana Celular/metabolismo , Escherichia coli/metabolismo , Fémur/química , Concentración de Iones de Hidrógeno , Intestinos/química , Masculino , Ratones , Proyectos Piloto , Suero/química
11.
Pak J Pharm Sci ; 30(2): 363-367, 2017 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-28649057

RESUMEN

A complex of low-molecular cationic peptides, extracted from human urine by a combination membrane ultrafiltration and weak cation exchange chromatography, was characterized in this study. It provides a simpler solution for the development of novel antimicrobial peptides from biological liquid waste.


Asunto(s)
Péptidos Catiónicos Antimicrobianos/aislamiento & purificación , Péptidos Catiónicos Antimicrobianos/farmacología , Orina/química , Cromatografía por Intercambio Iónico , Relación Dosis-Respuesta a Droga , Humanos , Masculino , Pruebas de Sensibilidad Microbiana , Ultrafiltración
12.
Zhonghua Yi Xue Yi Chuan Xue Za Zhi ; 33(4): 555-8, 2016 Aug.
Artículo en Chino | MEDLINE | ID: mdl-27455020

RESUMEN

OBJECTIVE: To establish a modified method for microculturing whole human blood for cytogenetic analysis. METHODS: A novel tube rack was designed to overcome the drawbacks of directly culturing the cells within centrifuge tubes. The fractions of human plasma, human serum and two commercial fetal bovine sera were analyzed with 15% sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE). The influence of adding 0%, 5%, 10%, 15%, 20%, 25% and 30% autologous plasma to the culture on lymphocyte transformation rate and mitotic index (MI) was examined. RESULTS: The SDS-PAGE analysis showed a significant difference between commercial fetal bovine sera, and that the components of human plasma were similar to those of fetal bovine serum. The value of MI in lymphocyte was evidently increased along with addition of autologous plasma. However, this has exerted no significant effect on the transformation rate. With the addition of 10% autologous plasma, the MI value has become much higher than the conventional method. CONCLUSION: A modified method was established by application of a novel tube inclined rack and optimization of whole blood inoculation. This method is easier and cheaper, and is suitable for application in clinical practice.


Asunto(s)
Técnicas de Cultivo de Célula/métodos , Citogenética , Linfocitos/ultraestructura , Adolescente , Adulto , Femenino , Humanos , Masculino , Índice Mitótico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA