Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Ann Card Anaesth ; 19(3): 475-80, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27397452

RESUMEN

CONTEXT: One of the main limitations of off-pump coronary artery bypass grafting (OPCAB) is the occasional need for intraoperative conversion (IOC) to on-pump coronary artery bypass grafting. IOC is associated with a significantly increased risk of mortality and postoperative morbidity. The impact of IOC on outcome cannot be assessed by a randomized control design. AIMS: The objective of this study was to analyze the incidence, risk factors, and impact of IOC on the outcome in patients undergoing OPCAB. SETTINGS AND DESIGN: Three tertiary care level hospitals; retrospective observational study. SUBJECTS AND METHODS: This retrospective observational study included 1971 consecutive patients undergoing  OPCAB from January 2012 to October 2015 at three tertiary care level hospitals by four surgeons. The incidence, patient characteristics, cause of IOC, and its impact on outcome were studied. STATISTICAL ANALYSIS USED: The cohort was divided into two groups according to IOC. Univariate logistic regression was performed to describe the predictors of IOC. Variables that were found to be significant in univariate analysis were introduced into multivariate model, and adjusted odds ratio (OR) was calculated. To further assess the independent effect of IOC on mortality, propensity score matching with a 5:1 ratio of non-IOC to IOC was performed. RESULTS: The overall all-cause in-hospital mortality was 2.6%. IOC was needed in 128 (6.49%) patients. The mortality in the IOC group was significantly higher than non-IOC group (21 of 128 [16.4%] vs. 31 of 1843 [1.7%], P = 0.0001). The most common cause for IOC was hemodynamic disturbances during grafting to the obtuse marginal artery (51/128; 40%). On multivariate logistic regression analysis, left main disease, pulmonary hypertension, and mitral regurgitation independently predicted IOC. We obtained a propensity-matched sample of 692 patients (No IOC 570; IOC 122), and IOC had OR of 16.26 (confidence interval 6.3-41; P < 0.0001) for mortality in matched population. CONCLUSIONS: Emergency IOC increases odds for mortality by 16-fold. Hence, identification of patients at higher risk of IOC may improve the outcome.


Asunto(s)
Puente de Arteria Coronaria/mortalidad , Mortalidad Hospitalaria , Cuidados Intraoperatorios/mortalidad , Cuidados Intraoperatorios/métodos , Complicaciones Posoperatorias/etiología , Puente de Arteria Coronaria/efectos adversos , Puente de Arteria Coronaria/métodos , Puente de Arteria Coronaria Off-Pump/efectos adversos , Puente de Arteria Coronaria Off-Pump/métodos , Puente de Arteria Coronaria Off-Pump/mortalidad , Femenino , Humanos , Incidencia , Cuidados Intraoperatorios/efectos adversos , Masculino , Persona de Mediana Edad , Oportunidad Relativa , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo
2.
Ann Card Anaesth ; 19(2): 231-9, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27052062

RESUMEN

CONTEXT: Left ventricle diastolic dysfunction (LVDD) is gaining importance as useful marker of mortality and morbidity in cardiac surgical patients. Different algorithms have been proposed for the intraoperative grading of DD. Knowledge of the particular grade of DD has clinical implications with the potential to modify therapy, but there is a paucity of literature on the role of diastolic function evaluation during off-pump coronary artery bypass grafting (OPCABG) surgery. AIMS: The aim of this study was to monitor changes in LVDD using simplified algorithm proposed by Swaminathan et al. in patients undergoing OPCABG. SETTINGS AND DESIGN: The study was conducted in a tertiary care level hospital; this was a prospective, observational study. SUBJECTS AND METHODS: Fifty consecutive patients undergoing OPCABG were enrolled. Hemodynamic and echocardiographic parameters were measured at 6 stages in every patient namely after anesthetic induction (baseline), during left internal mammary artery (LIMA) to left anterior descending (LAD) grafting (LIMA → LAD), saphenous vein graft (SVG) to obtuse marginal (OM) grafting (SVG → OM), SVG to posterior descending artery (PDA) grafting (SVG → PDA), during proximal anastomosis of SVG to aorta, and postprotamine. The patients were classified in grades of LVDD as per simplified algorithm proposed by Swaminathan et al. using only intraoperatively measured E and E'. RESULTS: The success rate of measurement and classification of LVDD was 98.92% (277 out of 280 measurements). The grades of LVDD varied significantly as per surgical steps with maximum downgrading occurring during OM and LAD grafting. During OM grafting, none of the patients had normal diastolic function while 29% of patients exhibited restrictive pattern (Grade 3 LVDD). Patients with normal baseline LV diastolic function also exhibited downgrading during OM and LAD grafting. Postprotamine, 37% of patients with normal baseline diastolic function continued to exhibit some degree of DD. CONCLUSIONS: The LVDD changes dynamically during various stages of OPCABG, which can be successfully monitored with simplified algorithm.


Asunto(s)
Algoritmos , Puente de Arteria Coronaria Off-Pump/métodos , Diástole , Monitoreo Intraoperatorio/métodos , Disfunción Ventricular Izquierda/diagnóstico , Anciano , Ecocardiografía Doppler , Femenino , Hemodinámica , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Factores de Riesgo , Disfunción Ventricular Izquierda/clasificación , Disfunción Ventricular Izquierda/diagnóstico por imagen
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA