Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 119
Filtrar
1.
Anal Chem ; 96(37): 15042-15049, 2024 Sep 17.
Artículo en Inglés | MEDLINE | ID: mdl-39219053

RESUMEN

Despite many luminescent advantages including outstanding absorption coefficient and high quantum yield, pyrene and its derivatives have been suffering from a dramatic aggregation-caused quenching (ACQ) effect. Although the dramatic ACQ effect of pyrene-based fluorophores has been restrained in pyrene-doped metal-organic frameworks (MOFs), the low loading of fluorescent (FL) units substantially impedes the improved luminescent behaviors. Herein, pyrene-based MOFs hydrogel was synthesized with a high loading of pyrene as the unique organic linker blocks instead of a dopant in MOFs. The gel matrix contributed to rigidifying the location of the FL emitters and achieving intensive FL emission and high luminescent stability and therefore efficiently overcoming the ACQ effect. Furthermore, the protonation of pyrene in the MOFs hydrogel remarkably decreased the luminescent intensity, which endowed the FL hydrogel with highly pH-responsive activity in the broad range (pH 4-10). Interestingly, glucose oxidase was immobilized into ZIF-8 as a highly efficient luminescent quencher, which contributed to catalyzing the form of gluconic acid and thus drastically quenching the FL signal of the MOFs hydrogel. Furthermore, the emitter-quencher pair of pyrene-based MOFs hydrogel and glucose oxidase was successfully employed to develop an ultrasensitive FL immunoassay platform for cardiac troponin I (as a model analyte). The limit of detection for cardiac troponin I was 5.2 pg/mL (3σ). The proof-of-principle study demonstrated the thrilling auxiliary effect of tailorable MOFs hydrogel on boosting the feasibility of aqueous insoluble FL chromophores for trace analysis.


Asunto(s)
Hidrogeles , Estructuras Metalorgánicas , Pirenos , Troponina I , Pirenos/química , Estructuras Metalorgánicas/química , Troponina I/análisis , Troponina I/sangre , Concentración de Iones de Hidrógeno , Humanos , Hidrogeles/química , Inmunoensayo/métodos , Colorantes Fluorescentes/química , Fluorescencia
2.
Biosens Bioelectron ; 265: 116711, 2024 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-39186893

RESUMEN

Serious adverse drug reactions of gentamicin (GM) significantly limit its clinical use, thus there is an urgent demand to develop reliable strategies to detect its concentration. In this study, we have developed a novel highly sensitive and portable lateral flow immunoassay (LFIA) based on CoFe PBAs/WS2 nanozyme mediated chemiluminescence (CL) and photothermal (PT) dual-mode POCT biosensor for the detection of GM, which successfully combines sensitive laboratory analyses with portable in situ analyses in the field. In this proof-of-principle work, the dynamic detection ranges of CL-LFIA and PT-LFIA mode were 1 pg mL-1 to 100 ng mL-1 and 50 pg mL-1 to 100 ng mL-1 with the limits of detection of 0.33 and 16.67 pg mL-1, respectively. The whole detection of CL-LFIA and PT-LFIA could be completed within 15 min and 30 min, respectively. The recoveries of GM spiked into complex matrices including milk, urine, and serum for CL-LFIA and PT-LFIA were 90.94%-109.74% and 94.49%-109.31%, respectively, indicating the reliability and applicability of the dual-mode LFIA in real samples. The dual-mode POCT biosensor could effectively overcome the false problems with improving accuracy and sensitivity, enabling user to precisely detect GM by laboratory analysis or on-site analysis depending on the source condition. Due to the complementary properties of CL-LFIA and PT-LFIA, the developed POCT biosensor can effectively ensure high-performance detection, showing the potential application of accurately detecting drug concentration in clinical practice.


Asunto(s)
Técnicas Biosensibles , Gentamicinas , Límite de Detección , Mediciones Luminiscentes , Pruebas en el Punto de Atención , Gentamicinas/análisis , Gentamicinas/sangre , Técnicas Biosensibles/métodos , Inmunoensayo/métodos , Mediciones Luminiscentes/métodos , Humanos , Animales , Antibacterianos/análisis , Antibacterianos/sangre , Antibacterianos/orina , Leche/química , Cobalto/química
3.
Anal Chem ; 96(37): 15074-15080, 2024 Sep 17.
Artículo en Inglés | MEDLINE | ID: mdl-39215695

RESUMEN

Multimodal immunochromatographic sensors (ICSs) have acquired extensive attention since they not only provide reliable results by comparing the different output signals but also flexibly respond to various application environments. Herein, an ICS with triple signal outputs including colorimetry, temperature, and pressure was developed for sensitive detection of chlorothalonil. The multivalent Pt/Ti3C2Tx nanoparticles as signal tags were facilely synthesized by loading PtNPs onto single-layer Ti3C2Tx nanosheets with high surface area. The acquired Pt/Ti3C2TxNPs accelerated the rate-limiting step of the aerogenesis reaction of H2O2 for producing intensive pressure signals due to their significant catalase-mimic activity. Meanwhile, they showed desirable photothermal conversion efficiency in the near-infrared region for producing significant temperature signals. Furthermore, their deep color also allowed facile colorimetry by using the naked eye. Based on a competitive immunoassay, chlorothalonil was detected as a model analyte on this trimodal ICS platform. The detection limits for pressure, temperature, and colorimetric modes were 0.04, 0.09, and 5 ng mL-1, respectively. The recoveries for detecting chlorothalonil supplemented in Astragalus and Honeysuckle with pressure mode were 84.0-110% and 108-114%, respectively. Therefore, the ICS presented a portable, sensitive, accurate, and flexible multimodal strategy suitable for point-of-care testing.


Asunto(s)
Colorimetría , Nanocompuestos , Nitrilos , Platino (Metal) , Temperatura , Nanocompuestos/química , Platino (Metal)/química , Inmunoensayo/métodos , Nitrilos/química , Presión , Titanio/química , Límite de Detección
4.
Anal Chem ; 2024 Jul 18.
Artículo en Inglés | MEDLINE | ID: mdl-39023129

RESUMEN

Single-dispersed atoms (SDAs) as catalysts have drawn extensive attention due to their ultimate atom utilization efficiency and desirable catalytic capability. Atomic clusters (ACs) with potential multiple enzyme-like activities also display great practicability in catalysis-based biosensing. In this work, hybrid Mn ACs/SDAs were implanted in the frameworks of defect-engineered MIL 101(Cr) modulated by excess acetic acid, with a high loading capability of 13.9 wt %. Distinctively, Mn SDAs display weak superoxide dismutase (SOD)-like activity for specifically eliminating superoxide anion (O2•-), while Mn ACs/SDAs display both catalase-like and SOD-like activities for remarkable elimination of total reactive oxygen species (ROS) due to the cooperative effect of the two atom-scale catalytic sites. Thus, Mn ACs/SDAs can efficiently inhibit the chemiluminescent (CL) emission of multiple ROS-mediated luminol systems with a superior quenching rate of 85.5%. To validate the practicability of Mn ACs/SDAs for a sensitive CL assay, an immunoassay method was established to detect acetamiprid by using Mn ACs/SDAs as signal quenchers, which displayed a quantification range of 10 pg mL-1-25 ng mL-1 and a detection limit of 3.3 pg mL-1. This study paves an avenue for developing ACs/SDAs with multiple antioxidant activities that are suitable for application in biosensing.

5.
Anal Chim Acta ; 1317: 342892, 2024 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-39030000

RESUMEN

BACKGROUND: Pathogenic bacteria are keeping threatening global public health since they can cause many infectious diseases. The traditional microorganism identification and molecular diagnostic techniques are insufficiently sensitive, time-consuming, or expensive. Thus it is of great interest to establish pressure signal-based sensing platforms for point-of-care testing of pathogenic bacteria to achieve timely diagnosis of infectious diseases. Rational design and synthesis of nano-sized probes with high peroxidase-mimicking activity have been a long-term cherished goal for improving the sensitivity of pressure signal-based sensing methods. RESULTS: Guided by nanoconfinement effect, PCN-222(Pt) was prepared by confining Pt clusters within the channels of a zirconium porphyrin MOFs material termed as PCN-222. In comparison to regular platinum nanoparticles, palladium@platinum core-shell nanodendrites, and platinum-coated gold nanoparticles, the prepared PCN-222(Pt) displayed superior peroxidase-mimicking activity with outstanding efficiency for catalyzing the decay of H2O2 to produce O2. Thus it was used as a pressure signal probe to establish a sensitive method on a hydrogel pellets platform for analyzing Pseudomonas aeruginosa (P. aeruginosa), for which polymyxin B and a phage termed as JZ1 were used as recognition agents for the target pathogen. P. aeruginosa was quantified with a handheld pressure meter within a broad range of 2.2 × 102-2.2 × 107 cfu mL-1. This method was used to quantify P. aeruginosa in various biological and food samples with acceptable accuracy and reliability. SIGNIFICANCE: The proposed nanoconfinement-guided protocol provides a novel approach for rational design and preparation of nano-sized probes with high peroxidase-mimicking activity for catalyzing gas-generation reaction. Thus this study opens an avenue for establishment of sensitive pressure signal-based sensing methods for pathogenic bacteria, which shows broad application prospects in medical diagnosis of infectious diseases.


Asunto(s)
Peróxido de Hidrógeno , Platino (Metal) , Pruebas en el Punto de Atención , Pseudomonas aeruginosa , Pseudomonas aeruginosa/aislamiento & purificación , Catálisis , Peróxido de Hidrógeno/química , Platino (Metal)/química , Paladio/química , Nanopartículas del Metal/química , Circonio/química , Porfirinas/química , Estructuras Metalorgánicas/química , Humanos
6.
Anal Chem ; 96(6): 2702-2710, 2024 02 13.
Artículo en Inglés | MEDLINE | ID: mdl-38289033

RESUMEN

Design of a ratiometric method is a promising pathway to improve the sensitivity and reliability of electrochemiluminescent (ECL) assay, for which the signals produced at two distinct potentials change reversely as it is applied to the target analyte. Herein, a biosensor for ECL assay of methicillin-resistant Staphylococcus aureus (MRSA) was constructed by immobilizing porcine IgG for capturing MRSA onto an electrode that was precoated with ß-cyclodextrin-conjugated luminol nanoparticles (ß-CD-Lu NPs) as an anodic luminophore. MOF PCN 224 loaded with an atomically distributed Zn element (PCN 224/Zn) was conjugated with phage recombinant cellular-binding domain (CBD) to act as a cathodic luminophore for tracing MRSA. After the formation of the sandwich complex of ß-CD-Lu NPs-porcine IgG/MRSA/PCN 224/Zn-CBD on the biosensor, two ECL reactions were triggered with cyclic voltammetry. The anodic process of the ß-CD-Lu NPs-H2O2 system and the cathodic process of the PCN 224/Zn-S2O82- system competed to react with reactive oxygen species (ROS) for producing ECL emission, which led to a reverse change of the two signals. Meanwhile, the overlap of the ß-CD-Lu NPs emission spectrum and PCN 224/Zn absorption spectrum effectively triggered ECL resonance energy transfer between the donor (ß-CD-Lu NPs) and the acceptor (PCN 224/Zn). Thus, a ratiometric ECL method was proposed for assaying MRSA with a dual-mechanism-driven mode. The detection limit for assaying MRSA is as low as 12 CFU/mL. The biosensor was applied to assay MRSA in various biological samples with recoveries ranging from 84.9 to 111.3%.


Asunto(s)
Técnicas Biosensibles , Nanopartículas del Metal , Staphylococcus aureus Resistente a Meticilina , Animales , Porcinos , Mediciones Luminiscentes/métodos , Reproducibilidad de los Resultados , Peróxido de Hidrógeno , Técnicas Biosensibles/métodos , Inmunoglobulina G , Técnicas Electroquímicas/métodos , Límite de Detección , Nanopartículas del Metal/química
7.
J Pharm Biomed Anal ; 240: 115931, 2024 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-38183730

RESUMEN

Pseudomonas aeruginosa (P. aeruginosa) with noticeable drug-resistance profile is one of the most pernicious pathogens that attracts major public health concerns. Herein, a 3D printed device combined with hydrogel pellet modified with phages was designed for point-of-care testing (POCT) of this pathogen with both colorimetric and pressure readout modes. A P. aeruginosa phage belonging to the family of Podoviridae was isolated from river water and noted as vB_PaeP-JZ1 (JZ1). Due to its host specificity, phage JZ1 was used as a recognizing agent for modifying the hydrogel pellet, and the modified hydrogel pellet was assembled into the 3D printed device to act as the sensing interface. Polymyxin B (PMB) was tagged with Pd@Pt core-shell nanodendrites (Pd@PtNDs) showing excellent peroxidase-like activity to act as the colorimetric and pressure signal tracer. P. aeruginosa can be quantified within the concentration ranges of 2.6 × 103 cfu mL-1 - 2.6 × 108 cfu mL-1 and 2.6 × 102 cfu mL-1 - 2.6 × 107 cfu mL-1 with colorimetric and pressure readout modes, respectively. The both modes can achieve quantitation of P. aeruginosa within 25 min. Thus the "both-in-one" 3D printed device with dual-mode readout function offers a rapid, sensitive, and specific platform for POCT of pathogenic bacteria.


Asunto(s)
Bacteriófagos , Infecciones por Pseudomonas , Humanos , Pseudomonas aeruginosa , Colorimetría , Hidrogeles , Infecciones por Pseudomonas/microbiología , Impresión Tridimensional
8.
Anal Chem ; 95(49): 18233-18240, 2023 Dec 12.
Artículo en Inglés | MEDLINE | ID: mdl-38016786

RESUMEN

Owing to the remarkable catalytic attributes, single-atom catalysts (SACs) have exhibited promising application prospects as the substitutes of natural enzymes. However, the low loading amount of atomic sites on typical SACs (no more than 5 wt %) significantly restricts their increased capability. Hereby, a layer growth inhibitor protocol was attempted to optimize anchoring isolated Co atoms efficiently on ultrathin monolayer layered double hydroxides (LDHs). Superior to the conventional multiple-layer LDHs, the synthesized monolayer LDHs (7.29 nm-thick) served as the emerging support for dispersing substantial active sites and featured a dramatic loading content of 32.5 wt %. Through X-ray absorption spectroscopy, the atomically dispersed active centers on Co SACs were verified as Co-N4 moieties. The results of radical scavenger experiments and electron paramagnetic resonance spectroscopy showed that Co SACs were favorable to the high yield of reactive oxygen species originating from the decomposition of H2O2. Therefore, Co SACs functioned as a sensitive enhancer to drastically boost the luminol-H2O2 chemiluminescence intensity by ∼4713-fold, which excelled drastically over these previously reported SACs. Furthermore, Co SACs were adopted as chemiluminescent probes for the quantitation of chlorothalonil, wherein a low detection limit of 49 pg mL-1 (3σ) was achieved. Additionally, the successful application in recovery trials demonstrated the favorable feasibility of Co SACs. The facile layer growth inhibitor protocol affords SACs with improved loading properties and even superior catalytic performances for sensitive luminescent bioassays.

9.
Anal Chim Acta ; 1282: 341909, 2023 Nov 22.
Artículo en Inglés | MEDLINE | ID: mdl-37923406

RESUMEN

BACKGROUND: Dual atomic site catalysts (DASCs) have aroused extensive interest in analytical chemistry on account of the superb catalytic activity caused by the highly-exposed active centers and synergistic effect of adjacent active centers. The reported protocols for preparing DASCs usually involve harsh conditions such as acid/base etching and high-temperature calcination, leading to unfavorable water dispersity and restricted application. It is crucial to develop DASCs with satisfactory water dispersity, improved stability, and mild preparation procedures to facilitate their application as signal probes in analytical chemistry. RESULTS: Formic acid was adopted as a modulator for preparing MOF-808 with abundant defective sites, which was used as the carrier for implanting Co atoms. Co DASCs with a special coordination structure of Co2-O10 and a high loading efficiency of 11.1 wt% were prepared with a mild solvothermal protocol. The resultant Co DASCs can significantly accelerate decay of H2O2 for forming numerous reactive oxygen radicals and boost chemiluminescent (CL) signal. Co DASCs at 1.0 µg mL-1 can enhance the CL signal of luminol-H2O2 system by about 5800 times. Thanks to their satisfactory water dispersity and excellent CL enhancement performance, they were used as ultra-sensitive CL signal probes for monitoring methicillin-resistant Staphylococcus aureus. The method shows a detection range of 102-107 CFU mL-1 and a detection limit of 47 CFU mL-1. Antibiotic susceptibility test was performed with the established CL method to prove its practicality. SIGNIFICANCE: The water dispersible Co DASCs prepared with facile and mild solvothermal protocol exhibit prominent peroxidase-like activity and can promote the production of reactive oxygen radicals for boosting CL signal. Therefore, this study paves an avenue for implanting DASCs in defect-engineered carrier to prepare signal probes suitable for development of ultra-sensitive CL analytical methods.


Asunto(s)
Staphylococcus aureus Resistente a Meticilina , Especies Reactivas de Oxígeno , Peróxido de Hidrógeno/química , Mediciones Luminiscentes/métodos , Luminol/química , Bacterias , Agua
10.
Biosens Bioelectron ; 239: 115629, 2023 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-37634422

RESUMEN

Severe antimicrobial resistance calls for developing rapid, sensitive and affordable methodological platform for clinical diagnosis of bacterial infection. Herein, a paper-based analytical device (PAD) for fluorescent (FL) detection and antimicrobial susceptibility test (AST) of Pseudomonas aeruginosa (P. aeruginosa) was fabricated by defining 96 hydrophilic microzones on a filter paper using a handheld stamp dipped with liquid wax. The size of microzones was designed to be consistent with traditional 96-well microplate, thus the FL signals can be collected by a commercialized microplate reader. Streptavidin was immobilized into the microzones by chitosan-glutaraldehyde crosslinking reaction, and then biotinylated bacteriophage tail fiber protein (TFP) was conjugated through biotin-streptavidin affinity system. TFP and fluorescein isothiocyanate (FITC) labeled antimicrobial peptide were used as capture agent and signal probe, respectively, for FL detection of P. aeruginosa on the PAD. The linear range for quantifying P. aeruginosa is 1.0 × 103 CFU/mL to 1.0 × 107 CFU/mL, with a detection limit of 137 CFU/mL. The PAD was also applied to conduct AST of P. aeruginosa for imipenem, meropenem, cefepime, amikacin, and gentamicin, and the results are consistent with the traditional broth dilution method. The PAD provides an affordable diagnosis platform for bacterial infection, especially in resource-limited institutes and countries.


Asunto(s)
Antiinfecciosos , Bacteriófagos , Técnicas Biosensibles , Estreptavidina , Bacterias , Colorantes
11.
Mikrochim Acta ; 190(9): 342, 2023 08 04.
Artículo en Inglés | MEDLINE | ID: mdl-37540283

RESUMEN

As a front-line chemotherapeutic drug for maintenance and consolidation therapy, methotrexate (MTX) has widely been applied to treat various tumors and some inflammatory diseases. However, because of its severe toxicity ascribed to low selectivity, it is necessary to monitor therapeutic drugs in high-dose MTX therapeutic regimens to ensure treatment safety. In this work, we developed a fluorescent immunochromatographic test strip (FITS) for monitoring MTX by employing time-resolved fluorescent microspheres as signal probes. With a competitive immunoassay mode, the FITS for MTX shows a super-wide dynamic range of 10 pM-10 µM, covering the entire clinical therapeutic concentration range of MTX. Therapeutic drug monitoring of MTX can be achieved within 7 min with high specificity, facilitating the timely rescue of drug poisoning led by high-dose MTX treatment. The method was employed for monitoring MTX in the spiked human serum, urine, and milk, showing acceptable recoveries ranging from 94.0 to 110.0%. The established FITS has been applied to MTX detection in serum obtained from high-dose MTX treatment. The results from FITS and enzyme multiplied immunoassay technique showed no significant difference, suggesting its reliability for usage in real biological samples. The device shows promise in point-of-care therapeutic drug monitoring for resource-limited countries and institutes, which significantly facilitates overcoming the lag time between sampling and results.


Asunto(s)
Metotrexato , Neoplasias , Humanos , Monitoreo de Drogas/métodos , Reproducibilidad de los Resultados , Microesferas
12.
Langmuir ; 39(36): 12785-12792, 2023 09 12.
Artículo en Inglés | MEDLINE | ID: mdl-37643321

RESUMEN

The application of active metal-based nanoscale catalysts as signal enhancers for chemiluminescent immunoassay (CLIA) is restricted by poor thermodynamic stability and ease of aggregation. For the present exploration, zirconium-based MOFs UiO-66-NH2 were adopted as supports to load cobalt species by an impregnation-reduction approach. Cobalt species were uniformly distributed in the framework architecture of the MOF materials. The prepared cobalt-loaded MOF hybrids, noted as UiO-66-NH2/Co, display superior chemiluminescence (CL) catalytic activity owing to the introduction of cobalt catalytic centers. The CL catalytic capability of UiO-66-NH2/Co hybrids is about 18 times of that of free cobalt ions at the same cobalt amount. The results of mechanism exploration manifest that the hybrids are capable of accelerating the decay of hydrogen peroxide and promoting the yield of reactive oxygen species. Based on their remarkable CL catalytic capability, a CLIA approach was proposed to monitor carbendazim by adopting the hybrids as signal probes, which showed the merits of high sensitivity and satisfactory selectivity. Carbendazim was quantitated within a concentration range of 0.05 to 60 ng mL-1, with a detection limit of 19.8 pg mL-1. The results for monitoring spiked samples verify the acceptable practicality of the proposed CLIA approach.


Asunto(s)
Bencimidazoles , Cobalto , Carbamatos
13.
Food Chem ; 428: 136774, 2023 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-37433255

RESUMEN

In this work, a lateral flow assay for Listeria monocytogenes was developed based on phage tail fiber protein (TFP) and triple-functional nanozyme probes with capture-separation-catalytic activity. Inspired by interaction between phage and bacteria, TFP of L. monocytogenes phage was immobilized on test line as capture molecule, which replaced traditional antibody and aptamer. After Gram-positive bacteria was captured and separated from samples by nanozyme probes modified with vancomycin (Van), TFP specifically recognized L. monocytogenes and overcame non-specific binding of Van. Special color reaction between Coomassie Brilliant Blue and bovine serum albumin which was an amplification carrier on probe was simply utilized as control zone to replace traditional control line. Relying on enzyme-like catalytic activity of nanozyme, this biosensor realized improved sensitivity and colorimetric quantitative detection with a detection limit of 10 CFU mL-1. Analytic performance results suggested this TFP-based biosensor provided a portable, sensitive and specific strategy to detect pathogen.


Asunto(s)
Bacteriófagos , Técnicas Biosensibles , Listeria monocytogenes , Vancomicina , Técnicas Biosensibles/métodos , Fenómenos Magnéticos
14.
Anal Chem ; 95(24): 9366-9372, 2023 06 20.
Artículo en Inglés | MEDLINE | ID: mdl-37276189

RESUMEN

Single-atom nanozymes (SANs) with highly exposed active sites and remarkable catalytic activity have shown noteworthy practicability in heterogeneous catalysis-based bioassay. Nevertheless, most of them were reported with peroxidase-like activity and ordinary loading capability. It is still a challenge to prepare high-loading SANs with desirable superoxide dismutase (SOD)-like activity. In this work, Mn SAN was successfully confined in the frameworks of Prussian blue analogues formed on Ti3C2 MXene sheets with the assistance of massive surfactants, which show a superior loading efficiency of 13.5 wt % (typically <2.0 wt %). The prepared Mn SAN exhibits desirable superoxide radical anion elimination capability because of its SOD-like activity. Moreover, due to the wide-spectrum absorption behavior of the carriers, Mn SAN shows a synergistically quenching efficiency up to 98.89% on the emission of the reactive oxygen species-mediated chemiluminescent (CL) system. Inspired by these features, a CL quenching method was developed on a lateral flow test strip platform by utilizing Mn SAN as a signal quencher and acetamiprid as a model analyte. The method for detecting acetamiprid shows a detection range of 1.0-10,000 pg mL-1 and a limit of detection of 0.3 pg mL-1. Its accuracy has been validated by detecting acetamiprid in medicinal herbs with acceptable recoveries. This work opens an avenue for preparing SANs with a surfactant-assisted protocol and pioneers the study of SANs with SOD-like activity in bioassay.


Asunto(s)
Superóxido Dismutasa , Superóxidos , Superóxido Dismutasa/química , Especies Reactivas de Oxígeno , Catálisis
15.
Anal Chem ; 95(26): 10008-10016, 2023 07 04.
Artículo en Inglés | MEDLINE | ID: mdl-37342882

RESUMEN

Phages have already been employed to detect bacteria because of their specific recognition capability and strong infectious activity toward their host. However, the reported single-phage-based techniques are inevitably restricted by false negative results that arose from extremely high strain specificity of phages. In this study, a cocktail composed of three Klebsiella pneumoniae (K. pneumoniae) phages was prepared as a recognition agent to broaden the recognition spectrum for detecting this bacterial species. A total of 155 clinically isolated strains of K. pneumoniae collected from four hospitals were adopted to test its recognition spectrum. A superior recognition rate of 91.6% for the strains was achieved due to the complementarity of the recognition spectra of the three phages composed of the cocktail. However, the recognition rate is as low as 42.3-62.2% if a single phage is employed. Based on the wide-spectrum recognition capability of the phage cocktail, a fluorescence resonance energy transfer method was established for detecting K. pneumoniae strains by employing fluorescein isothiocyanate labeled to the phage cocktail and Au nanoparticles labeled to p-mercaptophenylboronic acid as energy donors and acceptors, respectively. The detection process can be completed within 35 min, with a wide dynamic range of 5.0 × 102-1.0 × 107 CFU/mL. The application potential was verified by applying it to quantitate K. pneumoniae in different sample matrixes. This pioneer work opens an avenue for achieving wide-spectrum detection of different strains belonging to the same bacterial species with the phage cocktail.


Asunto(s)
Klebsiella pneumoniae , Klebsiella pneumoniae/química , Bacteriófagos/aislamiento & purificación , Especificidad de la Especie , Oro , Nanopartículas del Metal
16.
Langmuir ; 39(15): 5315-5322, 2023 Apr 18.
Artículo en Inglés | MEDLINE | ID: mdl-37018452

RESUMEN

Metal halide perovskites (MHPs) have been promising functional materials for developing solar cells, lasers, photodetectors, and sensors due to their outstanding optical and electrical characteristics. However, they suffer from very poor stability for their high sensitivity to some environmental factors such as temperature, UV irradiation, pH, and polar solvent, which limits their extensive practical applications. Herein, a derived metal organic framework material, Pb-ZIF-8, was prepared as a precursor via a doping protocol. Then, CH3NH3PbBr3 perovskites encapsulated in ZIF-8 (CH3NH3PbBr3@ZIF-8) with green fluorescent (FL) emission were synthesized via a facile in situ protocol by using the derived metal organic frameworks material as a source of Pb element. With the protection of encapsulated ZIF-8, the perovskites material shows good FL properties under various harsh environmental conditions, which facilitates facile application in various fields. To verify the practical application potential of CH3NH3PbBr3@ZIF-8, we utilized them as FL probes to establish a highly sensitive method for detecting glutathione. Furthermore, the rapid conversion process from non-FL Pb-ZIF-8 to FL CH3NH3PbBr3@ZIF-8 was utilized to realize encryption and decryption of confidential information. This work opens an avenue to the development of perovskites-based devices with greatly improved stability in harsh external environments.

17.
Anal Chem ; 95(7): 3754-3760, 2023 02 21.
Artículo en Inglés | MEDLINE | ID: mdl-36758121

RESUMEN

Non-tuberculosis mycobacteria (NTM) is one family of pathogens usually leading to nosocomial infections. Exploration of high-performance biological recognition agent plays a pivotal role for the development of point-of-care testing device and kit for detecting NTM. Mycobacterium smegmatis (M. smegmatis) is a NTM which has been frequently applied as an alternative model for highly pathogenic mycobacteria. Herein, a recombinant tail protein derived from mycobacteriophage SWU1 infecting M. smegmatis was expressed with Escherichia coli system and noted as GP89. It shows a fist-like structure according to the results of homology modeling and ab initio modeling. It is confirmed as a lipoarabinomannan (LAM) binding protein, which can recognize studied NTM genus since abundant LAM constructed with d-mannan and d-arabinan is distributed over the mycobacterial surface. Meanwhile an enhanced green fluorescent protein (eGFP)-fused GP89 protein was acquired with a fusion expression technique. Then GP89 and eGFP-fused GP89 were applied to establish a sensitive and rapid method for fluorescent detection of M. smegmatis with a broad linear range of 1.0 × 102 to 1.0 × 106 CFU mL-1 and a low detection limit of 69 CFU mL-1. Rapid and reliable testing of antimicrobial susceptibility was achieved by the GP89-based fluorescent method. The present work provides a promising recognition agent for studied NTM and opens an avenue for clinical diagnosis of NTM-induced infections.


Asunto(s)
Micobacteriófagos , Mycobacterium tuberculosis , Mycobacterium , Proteínas Portadoras , Micobacterias no Tuberculosas , Mycobacterium smegmatis
18.
Anal Chem ; 95(2): 1359-1365, 2023 01 17.
Artículo en Inglés | MEDLINE | ID: mdl-36575992

RESUMEN

Pressure has been a facile signal readout mode for developing point-of-care testing devices due to the attractive features of portability, accessibility, rapidity, and affordability. Herein, a pressure signal readout device was designed by integrating two homemade needle-type piezoresistive transducers, a controller for a thin-film piezoresistive sensor and a smartphone. Meanwhile, a bidirectional immunochromatographic test strip was designed as an immunoreaction platform for dual-analyte detection. Using PdCuPt nanoparticles with catalase-mimic activity as signal tags, the pressure signals triggered by catalyzed aerogenous reaction were monitored by the pressure signal readout device and read on a smartphone with the Bluetooth module. In this proof-of-principle work, imidacloprid and carbendazim were detected as model analytes. The dynamic ranges for quantitating imidacloprid and carbendazim are 20 pg mL-1 to 50 ng mL-1 and 50 pg mL-1 to 50 ng mL-1, respectively. The whole immunoassay process was completed within 16 min. The recovery values for imidacloprid and carbendazim spiked into herbal medicines are 82.0-110.0 and 84.0-116.0%, respectively, verifying its reliability for real sample detection. As the smartphone APP and controller for a thin-film piezoresistive sensor contain 12 signal channels, the system can be easily extended to meet the demand for high-throughput screening.


Asunto(s)
Bencimidazoles , Teléfono Inteligente , Reproducibilidad de los Resultados , Inmunoensayo/métodos , Límite de Detección
19.
Dig Dis Sci ; 68(4): 1574-1584, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-35989385

RESUMEN

OBJECTIVES: Pancreatitis is the most common complication of post-endoscopic retrograde cholangiopancreatography (ERCP). There are currently no prediction models, particularly for post-ERCP pancreatitis (PEP) after biliary stent placement due to malignant biliary obstruction (MBO). To that end, we aim to develop and validate a predictive model for PEP. METHODS: We retrospectively analyzed the data of patients who underwent ERCP for biliary stent placement due to MBO at the Second Affiliated Hospital of Harbin Medical University from January 1, 2014 to August 31, 2021. The eligible patients were randomly allocated to the development and validation cohorts. A prediction model was built using the development cohort, and the model's effect was validated using a validation cohort. RESULTS: A total of 1524 patients were enrolled, including 1016 in the development cohort and 508 in the validation cohort, with an overall PEP rate of 7.1%. The model's predictors included acute pancreatitis history, the absence of pancreatic duct dilation, nonpancreatic cancer, difficult cannulation, and pancreatic injection. The area under the curve (AUC) in the development cohort was 0.810, and the incidence of PEP in the low-risk, medium-risk, and high-risk groups was 1.53%, 9.12%, and 36.36%, respectively. Meanwhile, the AUC of the validation cohort was 0.781, and the incidence of PEP in the low-risk, medium-risk, and high-risk groups was 4.17%, 8.75%, and 41.67%, respectively. CONCLUSIONS: This study was the first to build and validate a risk prediction model, especially for PEP after biliary stent placement due to MBO. Moreover, this model might assist clinicians in identifying high-risk patients and help implement preventive measures in a more timely manner.


Asunto(s)
Colestasis , Neoplasias , Pancreatitis , Humanos , Colangiopancreatografia Retrógrada Endoscópica/efectos adversos , Pancreatitis/epidemiología , Estudios Retrospectivos , Enfermedad Aguda , Stents/efectos adversos , Colestasis/diagnóstico por imagen , Colestasis/etiología , Colestasis/cirugía , Factores de Riesgo
20.
Anal Chim Acta ; 1232: 340478, 2022 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-36257748

RESUMEN

In view of the optimal catalytic efficiency (∼100%), single-atom site catalysts are being widely exploited in a range of areas including organic synthesis, energy conversion, environmental remediation, biotherapy, etc. However, low loading ratio of the unitary active sites on single-atom site catalysts dramatically hinders the remarkable improvement of their catalytic activity. Hereby, a facile low-temperature reduction protocol was adopted for synthesizing CoN4-supported Co2N metal clusters on graphitic carbon nitride, which show the remarkably superior chemiluminescent (CL) catalytic capacity than some reported pure single-atom site catalysts. Nitrogen-encapsulated Co2N clusters coupled with isolated Co-N4 moieties (Co2N@Co-N4) endowed the synergetic catalysts with high Co content of 53.2 wt%. Through X-ray absorption spectroscopy, the synergetic active sites (Co2N@Co-N4) afforded the CoN4-supported Co2N clusters with the remarkable catalytic activity for accelerating the decomposition of H2O2 to produce extensive superoxide radical anion rather than singlet oxygen or hydroxyl radical. Therefore, the CoN4-supported Co2N clusters possessed the superb enhancement effect on luminol-H2O2 CL reaction by ∼22829 times. The CoN4-supported Co2N clusters were utilized as signal probes to establish a CL immunochromatographic assay (ICA) platform for quantitating mycotoxins. Herein, aflatoxin B1 was employed as a mode analyte and the limit of detection was as low as 0.33 pg mL-1 (3σ). As a proof-of-principle work, the developed ICA protocol was successfully employed on the detection of aflatoxin B1 spiked in Angelica dahurica and Ganoderma lucidum with acceptable recoveries of 84.0-107.0%. The ideal practicability of the work elucidates that CoN4-supported Co2N clusters showed a new perspective for developing the sensitive CL biosensing.


Asunto(s)
Radical Hidroxilo , Luminol , Luminol/química , Superóxidos , Oxígeno Singlete/química , Peróxido de Hidrógeno/química , Límite de Detección , Aflatoxina B1 , Metales , Nitrógeno , Inmunoensayo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA