J Biomed Mater Res A ; 112(1): 99-109, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37929658

RESUMEN

Developing an ambulatory assist lung (AAL) for patients who need continuous extracorporeal membrane oxygenation has been associated with several design objectives, including the design of compact components, optimization of gas transfer efficiency, and reduced thrombogenicity. In an effort to address thrombogenicity concerns with currently utilized component biomaterials, a low molecular weight water soluble siloxane-functionalized zwitterionic sulfobetaine (SB-Si) block copolymer was coated on a full-scale AAL device set via a one pot aqueous circulation coating. All device parts including hollow fiber bundle, housing, tubing and cannular were successfully coated with increasing atomic compositions of the SB block copolymer and the coated surfaces showed a significant reduction of platelet deposition while gas exchange performance was sustained. However, water solubility of the SB-Si was unstable, and the coating method, including oxygen plasma pretreatment on the surfaces were considered inconsistent with the objective of developing a simple aqueous coating. Addressing these weaknesses, SB block copolymers were synthesized bearing epoxy or epoxy-silane groups with improved water solubility (SB-EP & SB-EP-Si) and no requirement for surface pretreatment (SB-EP-Si). An SB-EP-Si triblock copolymer showed the most robust coating capacity and stability without prior pretreatment to represent a simple aqueous circulation coating on an assembled full-scale AAL device.


Asunto(s)
Plaquetas , Silanos , Humanos , Polímeros , Pulmón , Agua
2.
ASAIO J ; 69(2): e86-e92, 2023 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-36716073

RESUMEN

For infants born at the border of viability, care practices and morbimortality rates vary widely between centers. Trends show significant improvement, however, with increasing gestational age and weight. For periviable infants, the goal of critical care is to bridge patients to improved outcomes. Current practice involves ventilator therapy, resulting in chronic lung injuries. Research has turned to artificial uterine environments, where infants are submerged in an artificial amniotic fluid bath and provided respiratory assistance via an artificial placenta. We have developed the Preemie-Ox, a hollow fiber membrane bundle that provides pumpless respiratory support via umbilical cord cannulation. Computational fluid dynamics was used to design an oxygenator that could achieve a carbon dioxide removal rate of 12.2 ml/min, an outlet hemoglobin saturation of 100%, and a resistance of less than 71 mmHg/L/min at a blood flow rate of 165 ml/min. A prototype was utilized to evaluate in-vitro gas exchange, resistance, and plasma-free hemoglobin generation. In-vitro gas exchange was 4% higher than predicted results and no quantifiable plasma-free hemoglobin was produced.


Asunto(s)
Órganos Artificiales , Placenta , Embarazo , Femenino , Humanos , Dióxido de Carbono , Cateterismo , Hemoglobinas , Diseño de Equipo , Membranas Artificiales , Oxígeno
3.
Transplantation ; 105(5): 999-1007, 2021 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-33031226

RESUMEN

BACKGROUND: A wearable artificial lung could improve lung transplantation outcomes by easing implementation of physical rehabilitation during long-term pretransplant respiratory support. The Modular Extracorporeal Lung Assist System (ModELAS) is a compact pumping artificial lung currently under development. This study evaluated the long-term in vivo performance of the ModELAS during venovenous support in awake sheep. Feedback from early trials and computational fluid dynamic analysis guided device design optimization along the way. METHODS: The ModELAS was connected to healthy sheep via a dual-lumen cannula in the jugular vein. Sheep were housed in a fixed-tether pen while wearing the device in a holster during support. Targeted blood flow rate and support duration were 2-2.5 L/min and 28-30 days, respectively. Anticoagulation was maintained via systemic heparin. Device pumping and gas exchange performance and hematologic indicators of sheep physiology were measured throughout support. RESULTS: Computational fluid dynamic-guided design modifications successfully decreased pump thrombogenicity from initial designs. For the optimized design, 4 of 5 trials advancing past early perioperative and cannula-related complications lasted the full month of support. Blood flow rate and CO2 removal in these trials were 2.1 ± 0.3 L/min and 139 ± 15 mL/min, respectively, and were stable during support. One trial ended after 22 days of support due to intradevice thrombosis. Support was well tolerated by the sheep with no signs of hemolysis or device-related organ impairment. CONCLUSIONS: These results demonstrate the ability of the ModELAS to provide safe month-long support without consistent deterioration of pumping or gas exchange capabilities.


Asunto(s)
Órganos Artificiales , Circulación Extracorporea/instrumentación , Trasplante de Pulmón , Pulmón/cirugía , Intercambio Gaseoso Pulmonar , Respiración , Animales , Diseño de Equipo , Circulación Extracorporea/efectos adversos , Pulmón/fisiopatología , Circulación Pulmonar , Oveja Doméstica , Factores de Tiempo
4.
ASAIO J ; 66(10): 1161-1165, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33136604

RESUMEN

Extracorporeal CO2 removal (ECCO2R) can permit lung protective or noninvasive ventilation strategies in patients with chronic obstructive pulmonary disease (COPD) and acute respiratory distress syndrome (ARDS). With evidence supporting ECCO2R growing, investigating factors which affect CO2 removal is necessary. Multiple factors are known to affect the CO2 removal rate (vCO2) which can complicate the interpretation of changes in vCO2; however, the effect of hematocrit on the vCO2 of artificial lungs has not been investigated. This in vitro study evaluates the relationship between hematocrit level and vCO2 within an ECCO2R device. In vitro gas transfer was measured in bovine blood in accordance with the ISO 7199 standard. Plasma and saline were used to hemodilute the blood to hematocrits between 33% and 8%. The vCO2 significantly decreased as the blood was hemodiluted with saline and plasma by 42% and 32%, respectively, between a hematocrit of 33% and 8%. The hemodilution method did not significantly affect the vCO2. In conclusion, the hematocrit level significantly affects vCO2 and should be taken into account when interpreting changes in the vCO2 of an ECCO2R device.


Asunto(s)
Órganos Artificiales , Dióxido de Carbono/sangre , Circulación Extracorporea/métodos , Hematócrito , Pulmón , Animales , Bovinos , Circulación Extracorporea/instrumentación , Ventilación no Invasiva/métodos , Enfermedad Pulmonar Obstructiva Crónica , Síndrome de Dificultad Respiratoria
5.
Intensive Care Med Exp ; 8(1): 45, 2020 Aug 17.
Artículo en Inglés | MEDLINE | ID: mdl-32804310

RESUMEN

BACKGROUND: Non-invasive and lung-protective ventilation techniques may improve outcomes for patients with an acute exacerbation of chronic obstructive pulmonary disease or moderate acute respiratory distress syndrome by reducing airway pressures. These less invasive techniques can fail due to hypercapnia and require transitioning patients to invasive mechanical ventilation. Extracorporeal CO2 removal devices remove CO2 independent of the lungs thereby controlling the hypercapnia and permitting non-invasive or lung-protective ventilation techniques. We are developing the Modular Extracorporeal Lung Assist System as a platform technology capable of providing three levels of respiratory assist: adult and pediatric full respiratory support and adult low-flow CO2 removal. The objective of this study was to evaluate the in vivo performance of our device to achieve low-flow CO2 removal. METHODS: The Modular Extracorporeal Lung Assist System was connected to 6 healthy sheep via a 15.5 Fr dual-lumen catheter placed in the external jugular vein. The animals were recovered and tethered within a pen while supported by the device for 7 days. The pump speed was set to achieve a targeted blood flow of 500 mL/min. The extracorporeal CO2 removal rate was measured daily at a sweep gas independent regime. Hematological parameters were measured pre-operatively and regularly throughout the study. Histopathological samples of the end organs were taken at the end of each study. RESULTS: All animals survived the surgery and generally tolerated the device well. One animal required early termination due to a pulmonary embolism. Intra-device thrombus formation occurred in a single animal due to improper anticoagulation. The average CO2 removal rate (normalized to an inlet pCO2 of 45 mmHg) was 75.6 ± 4.7 mL/min and did not significantly change over the course of the study (p > 0.05). No signs of consistent hemolysis or end organ damage were observed. CONCLUSION: These in vivo results indicate positive performance of the Modular Extracorporeal Lung Assist System as a low-flow CO2 removal device.

6.
ASAIO J ; 66(5): 565-570, 2020 05.
Artículo en Inglés | MEDLINE | ID: mdl-31335366

RESUMEN

Ambulating patients on extracorporeal membrane oxygenation (ECMO) or extracorporeal CO2 removal (ECCO2R) improves outcomes. These systems would further simplify ambulation if made more compact. This study investigates blood recirculation to decrease device size by increasing efficiency. The required hollow fiber membrane (HFM) area was determined by numerically modeling gas transfer. An oxygenation device with recirculating blood flow was designed using computational fluid dynamics (CFD). Hydrodynamic performance and shear stresses of the device were analyzed using CFD at 2,000, 2,250 and 2,500 RPM. A prototype (0.38 m) was manufactured for in-vitro oxygenation testing. Oxygenation was measured at a constant 3.5 L/min blood flow while recirculation flow rate varied up to 6.5 L/min. Hemolysis was measured at 3.5 L/min blood flow and 6.5 L/min recirculation flow. A 0.3 m prototype device was used to test in-vitro ECCO2R recirculation at a constant 500 ml/min blood flow rate and recirculation flow rates up to 5.5 L/min. Computational fluid dynamics analysis showed that the oxygenation device could produce over 250 mm Hg while maintaining 3.5 L/min blood flow and 6.5 L/min recirculation flow. The model predicted oxygenation within 8% and overestimated ECCO2R by up to 32%. Measured gas transfer was 180 ml O2/min and 62 ml CO2/min. Normalized index of hemolysis contribution of the HFM was 0.012 gm/100 L.


Asunto(s)
Diseño de Equipo , Oxigenación por Membrana Extracorpórea/instrumentación , Hidrodinámica , Modelos Teóricos , Animales , Bovinos , Pulmón , Ventiladores Mecánicos
7.
ASAIO J ; 65(4): 395-400, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30507846

RESUMEN

Respiratory failure is a significant problem within the pediatric population. A means of respiratory support that readily allows ambulation could improve treatment. The Pittsburgh Pediatric Ambulatory Lung (P-PAL) is being developed as a wearable pediatric pump-lung for long-term respiratory support and has previously demonstrated positive benchtop results. This study aimed to evaluate acute (4-6 hours) in vivo P-PAL performance, as well as develop an optimal implant strategy for future long-term studies. The P-PAL was connected to healthy sheep (n = 6, 23-32 kg) via cannulation of the right atrium and pulmonary artery. Plasma-free hemoglobin (PfHb) and animal hemodynamics were measured throughout the study. Oxygen transfer rates were measured at blood flows of 1-2.5 L/min. All animals survived the complete study duration with no device exchanges. Flow limitation because of venous cannula occlusion occurred in trial 2 and was remedied via an altered cannulation approach. Blood exiting the P-PAL had 100% oxygen saturation with the exception of trial 4 during which inadequate device priming led to intrabundle clot formation. Plasma-free hemoglobin remained low (<20 mg/dl) for all trials. In conclusion, this study demonstrated successful performance of the P-PAL in an acute setting and established the necessary methods for future long-term evaluation.


Asunto(s)
Diseño de Equipo , Oxigenación por Membrana Extracorpórea/instrumentación , Insuficiencia Respiratoria , Animales , Modelos Animales de Enfermedad , Hemodinámica/fisiología , Ovinos
8.
ASAIO J ; 65(1): 94-100, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-29240631

RESUMEN

Recent studies show improved outcomes in ambulated lung failure patients. Ambulation still remains a challenge in these patients. This necessitates development of more compact and less cumbersome respiratory support specifically designed to be wearable. The Paracorporeal Ambulatory Assist Lung (PAAL) is being designed for providing ambulatory support in lung failure patients during bridge to transplant or recovery. We previously published in vitro and acute in vivo results of the PAAL. This study further evaluates the PAAL for 5 days. Five-day in vivo studies with the PAAL were conducted in 50-60 kg sheep after heparinization (activated clotting time range: 190-250 s) and cannulation with a 27 Fr. Avalon Elite dual-lumen cannula. The animals were able to move freely in a stanchion while device flow, resistance, and hemodynamics were recorded hourly. Oxygenation and hemolysis were measured daily. Platelet activation, blood chemistry, and comprehensive blood counts are reported for preoperatively, on POD 0, and POD 5. Three animals survived for 5 days. No study termination resulted from device failure. One animal was terminated on POD 0 and one animal was terminated at POD 3. The device was operated between 1.93 and 2.15 L/min. Blood left the device 100% oxygenated. Plasma-free hemoglobin ranged 10.8-14.5 mg/dl. CD62-P expression was under 10%. Minimal thrombus was seen in devices at explant. Chronic use of the PAAL in awake sheep is promising based on our study. There were no device-related complications over the study course. This study represents the next step in our pathway to eventual clinical translation.


Asunto(s)
Diseño de Equipo , Circulación Extracorporea/instrumentación , Oxigenadores de Membrana , Dispositivos Electrónicos Vestibles , Animales , Hemodinámica , Insuficiencia Respiratoria , Ovinos
9.
Intensive Care Med Exp ; 6(1): 34, 2018 Sep 24.
Artículo en Inglés | MEDLINE | ID: mdl-30251223

RESUMEN

BACKGROUND: There is increasing evidence demonstrating the value of partial extracorporeal CO2 removal (ECCO2R) for the treatment of hypercapnia in patients with acute exacerbations of chronic obstructive pulmonary disease and acute respiratory distress syndrome. Mechanical ventilation has traditionally been used to treat hypercapnia in these patients, however, it has been well-established that aggressive ventilator settings can lead to ventilator-induced lung injury. ECCO2R removes CO2 independently of the lungs and has been used to permit lung protective ventilation to prevent ventilator-induced lung injury, prevent intubation, and aid in ventilator weaning. The Low-Flow Pittsburgh Ambulatory Lung (LF-PAL) is a low-flow ECCO2R device that integrates the fiber bundle (0.65 m2) and centrifugal pump into a compact unit to permit patient ambulation. METHODS: A blood analog was used to evaluate the performance of the pump at various impeller rotation rates. In vitro CO2 removal tested under normocapnic conditions and 6-h hemolysis testing were completed using bovine blood. Computational fluid dynamics and a mass-transfer model were also used to evaluate the performance of the LF-PAL. RESULTS: The integrated pump was able to generate flows up to 700 mL/min against the Hemolung 15.5 Fr dual lumen catheter. The maximum vCO2 of 105 mL/min was achieved at a blood flow rate of 700 mL/min. The therapeutic index of hemolysis was 0.080 g/(100 min). The normalized index of hemolysis was 0.158 g/(100 L). CONCLUSIONS: The LF-PAL met pumping, CO2 removal, and hemolysis design targets and has the potential to enable ambulation while on ECCO2R.

10.
Ann Biomed Eng ; 46(5): 762-771, 2018 May.
Artículo en Inglés | MEDLINE | ID: mdl-29464460

RESUMEN

Gas transfer through hollow fiber membranes (HFMs) can be increased via fiber oscillation. Prior work, however, does not directly translate to present-day, full-scale artificial lungs. This in vitro study characterized the effects of HFM oscillations on oxygenation and hemolysis for a pediatric-sized HFM bundle. Effects of oscillation stroke length (2-10 mm) and frequency (1-25 Hz) on oxygen transfer were measured according to established standards. The normalized index of hemolysis was measured for select conditions. All measurements were performed at a 2.5 L min-1 blood flow rate. A lumped parameter model was used to predict oscillation-induced blood flow and elucidate the effects of system parameters on oxygenation. Oxygen transfer increased during oscillations, reaching a maximum oxygenation efficiency of 510 mL min-1 m-2 (97% enhancement relative to no oscillation). Enhancement magnitudes matched well with model-predicted trends and were dependent on stroke length, frequency, and physical system parameters. A 40% oxygenation enhancement was achieved without significant hemolysis increase. At a constant enhancement magnitude, a larger oscillation frequency resulted in increased hemolysis. In conclusion, HFM oscillation is a feasible approach to increasing artificial lung gas transfer efficiency. The optimal design for maximizing efficiency at small fiber displacements should minimize bundle resistance and housing compliance.


Asunto(s)
Órganos Artificiales , Pulmón , Membranas Artificiales , Modelos Cardiovasculares , Oxígeno/sangre , Animales , Bovinos
11.
ASAIO J ; 64(6): 806-811, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29240630

RESUMEN

Acute and chronic respiratory failure are a significant source of pediatric morbidity and mortality. Current respiratory support options used to bridge children to lung recovery or transplantation typically render them bedridden and can worsen long-term patient outcomes. The Pittsburgh Pediatric Ambulatory Lung (P-PAL) is a wearable pediatric blood pump and oxygenator (0.3 m surface area) integrated into a single compact unit that enables patient ambulation. The P-PAL is intended for long-term use and designed to provide up to 90% of respiratory support in children weighing 5-25 kg. Computational fluid dynamics and numerical gas exchange modeling were used to design the P-PAL and predict its performance. A P-PAL prototype was then used to obtain pressure versus flow curves at various impeller rotation rates using a blood analog fluid. In vitro oxygen exchange rates were obtained in blood in accordance with ISO standard 7199. The normalized index of hemolysis (NIH) was measured over a 6 hour period at blood flow rates of 1 and 2.5 L/min. The P-PAL provided blood flows of 1-2.5 L/min against the pressure drop associated with its intended-use pediatric cannulas. The oxygen exchange rate reached a maximum of 108 ml/min at a blood flow rate of 2.5 L/min and met our respiratory support design target. Device-induced hemolysis was low with NIH values of 0.022-0.027 g/100 L in the intended blood flow rate range. In conclusion, the current P-PAL design met our pumping, oxygenation, and hemolysis specifications and has the potential to improve treatment for pediatric respiratory failure.


Asunto(s)
Diseño de Equipo , Respiración Artificial/instrumentación , Insuficiencia Respiratoria/terapia , Niño , Simulación por Computador , Humanos , Hidrodinámica
12.
Intensive Care Med Exp ; 5(1): 41, 2017 Sep 06.
Artículo en Inglés | MEDLINE | ID: mdl-28875449

RESUMEN

BACKGROUND: Extracorporeal carbon dioxide removal (ECCO2R) systems have gained clinical appeal as supplemental therapy in the treatment of acute and chronic respiratory injuries with low tidal volume or non-invasive ventilation. We have developed an ultra-low-flow ECCO2R device (ULFED) capable of operating at blood flows comparable to renal hemodialysis (250 mL/min). Comparable operating conditions allow use of minimally invasive dialysis cannulation strategies with potential for direct integration to existing dialysis circuitry. METHODS: A carbon dioxide (CO2) removal device was fabricated with rotating impellers inside an annular hollow fiber membrane bundle to disrupt blood flow patterns and enhance gas exchange. In vitro gas exchange and hemolysis testing was conducted at hemodialysis blood flows (250 mL/min). RESULTS: In vitro carbon dioxide removal rates up to 75 mL/min were achieved in blood at normocapnia (pCO2 = 45 mmHg). In vitro hemolysis (including cannula and blood pump) was comparable to a Medtronic Minimax oxygenator control loop using a time-of-therapy normalized index of hemolysis (0.19 ± 0.04 g/100 min versus 0.12 ± 0.01 g/100 min, p = 0.169). CONCLUSIONS: In vitro performance suggests a new ultra-low-flow extracorporeal CO2 removal device could be utilized for safe and effective CO2 removal at hemodialysis flow rates using simplified and minimally invasive connection strategies.

13.
J Heart Lung Transplant ; 36(7): 806-811, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-28359655

RESUMEN

BACKGROUND: Conventional extracorporeal membrane oxygenation (ECMO) is cumbersome and is associated with high morbidity and mortality. We are currently developing the Pittsburgh Ambulatory Assist Lung (PAAL), which is designed to allow for ambulation of lung failure patients during bridge to transplant or recovery. In this study, we investigated the in vitro and acute in vivo performance of the PAAL. METHODS: The PAAL features a 1.75-inch-diameter, cylindrical, hollow-fiber membrane (HFM) bundle of stacked sheets, with a surface area of 0.65 m2 integrated with a centrifugal pump. The PAAL was tested on the bench for hydrodynamic performance, gas exchange and hemolysis. It was then tested in 40- to 60-kg adult sheep (n = 4) for 6 hours. The animals were cannulated with an Avalon Elite 27Fr dual-lumen catheter (DLC) inserted through the right external jugular into the superior vena cava (SVC), right atrium (RA) and inferior vena cava (IVC). RESULTS: The PAAL pumped >250 mm Hg at 3.5 liters/min at a rotation speed of 2,100 rpm. Oxygenation performance met the target of 180 ml/min at 3.5 liters/min of blood flow in vitro, resulting in a gas-exchange efficiency of 278 ml/min/m2. The normalized index of hemolysis (NIH) for the PAAL and cannula was 0.054 g per 100 liters (n = 2) at 3.5 liters/min, as compared with 0.020 g per 100 liters (n = 2) for controls (DLC cannula and a Centrimag pump). Plasma-free hemoglobin (pfHb) was <20 mg/dl for all animals. Blood left the device 100% oxygenated in vivo and oxygenation reached 181 ml/min at 3.8 liters/min. CONCLUSION: The PAAL met in vitro and acute in vivo performance targets. Five-day chronic sheep studies are planned for the near future.


Asunto(s)
Órganos Artificiales , Oxigenación por Membrana Extracorpórea/instrumentación , Enfermedades Pulmonares/terapia , Animales , Modelos Animales de Enfermedad , Diseño de Equipo , Ovinos
14.
ASAIO J ; 63(5): 631-636, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28187049

RESUMEN

Mechanical ventilation (MV) and extracorporeal membrane oxygenation (ECMO) are the only viable treatment options for lung failure patients at the end-stage, including acute respiratory distress syndrome (ARDS) and chronic obstructive pulmonary disease (COPD). These treatments, however, are associated with high morbidity and mortality because of long wait times for lung transplant. Contemporary clinical literature has shown ambulation improves post-transplant outcomes in lung failure patients. Given this, we are developing the Pittsburgh Ambulatory Assist Lung (PAAL), a truly wearable artificial lung that allows for ambulation. In this study, we targeted 180 ml/min oxygenation and determined the form factor for a hollow fiber membrane (HFM) bundle for the PAAL. Based on a previously published mass transfer correlation, we modeled oxygenation efficiency as a function of fiber bundle diameter. Three benchmark fiber bundles were fabricated to validate the model through in vitro blood gas exchange at blood flow rates from 1 to 4 L/min according to ASTM standards. We used the model to determine a final design, which was characterized in vitro through a gas exchange as well as a hemolysis study at 3.5 L/min. The percent difference between model predictions and experiment for the benchmark bundles ranged from 3% to 17.5% at the flow rates tested. Using the model, we predicted a 1.75 in diameter bundle with 0.65 m surface area would produce 180 ml/min at 3.5 L/min blood flow rate. The oxygenation efficiency was 278 ml/min/m and the Normalized Index of Hemolysis (NIH) was less than 0.05 g/100 L. Future work involves integrating this bundle into the PAAL for which an experimental prototype is under development in our laboratory.


Asunto(s)
Órganos Artificiales , Pulmón , Insuficiencia Respiratoria/terapia , Oxigenación por Membrana Extracorpórea , Humanos , Pulmón/fisiopatología , Oxígeno/sangre , Enfermedad Pulmonar Obstructiva Crónica/terapia , Respiración Artificial , Síndrome de Dificultad Respiratoria/terapia
15.
ASAIO J ; 62(3): 329-31, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-26809086

RESUMEN

Hollow fiber membranes (HFMs) are used in blood oxygenators for cardiopulmonary bypass or in next generation artificial lungs. Flow analyses of these devices is typically done using computational fluid dynamics (CFD) modeling HFM bundles as porous media, using a Darcy permeability coefficient estimated from the Blake-Kozeny (BK) equation to account for viscous drag from fibers. We recently published how well this approach can predict Darcy permeability for fiber bundles made from polypropylene HFMs, showing the prediction can be significantly improved using an experimentally derived correlation between the BK constant (A) and bundle porosity (ε). In this study, we assessed how well our correlation for A worked for predicting the Darcy permeability of fiber bundles made from Membrana polymethylpentene (PMP) HFMs, which are increasingly being used clinically. Swatches in the porosity range of 0.4 to 0.8 were assessed in which sheets of fiber were stacked in parallel, perpendicular, and angled configurations. Our previously published correlation predicted Darcy within ±8%. A new correlation based on current and past measured permeability was determined: A = 497ε - 103; using this correlation measured Darcy permeability was within ±6%. This correlation varied from 8% to -3.5% of our prior correlation over the tested porosity range.


Asunto(s)
Órganos Artificiales , Puente Cardiopulmonar , Pulmón , Membranas Artificiales , Oxigenadores de Membrana , Humanos , Hidrodinámica , Permeabilidad , Porosidad
16.
Artif Organs ; 38(12): 1007-17, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24749994

RESUMEN

Providing partial respiratory assistance by removing carbon dioxide (CO2 ) can improve clinical outcomes in patients suffering from acute exacerbations of chronic obstructive pulmonary disease and acute respiratory distress syndrome. An intravenous respiratory assist device with a small (25 Fr) insertion diameter eliminates the complexity and potential complications associated with external blood circuitry and can be inserted by nonspecialized surgeons. The impeller percutaneous respiratory assist catheter (IPRAC) is a highly efficient CO2 removal device for percutaneous insertion to the vena cava via the right jugular or right femoral vein that utilizes an array of impellers rotating within a hollow-fiber membrane bundle to enhance gas exchange. The objective of this study was to evaluate the effects of new impeller designs and impeller spacing on gas exchange in the IPRAC using computational fluid dynamics (CFD) and in vitro deionized water gas exchange testing. A CFD gas exchange and flow model was developed to guide a progressive impeller design process. Six impeller blade geometries were designed and tested in vitro in an IPRAC device with 2- or 10-mm axial spacing and varying numbers of blades (2-5). The maximum CO2 removal efficiency (exchange per unit surface area) achieved was 573 ± 8 mL/min/m(2) (40.1 mL/min absolute). The gas exchange rate was found to be largely independent of blade design and number of blades for the impellers tested but increased significantly (5-10%) with reduced axial spacing allowing for additional shaft impellers (23 vs. 14). CFD gas exchange predictions were within 2-13% of experimental values and accurately predicted the relative improvement with impellers at 2- versus 10-mm axial spacing. The ability of CFD simulation to accurately forecast the effects of influential design parameters suggests it can be used to identify impeller traits that profoundly affect facilitated gas exchange.


Asunto(s)
Dióxido de Carbono/sangre , Catéteres , Diseño de Equipo , Insuficiencia Respiratoria/sangre , Insuficiencia Respiratoria/terapia , Humanos , Intercambio Gaseoso Pulmonar
17.
ASAIO J ; 55(6): 569-74, 2009.
Artículo en Inglés | MEDLINE | ID: mdl-19779302

RESUMEN

Respiratory assist using an intravenous catheter may be a potential treatment for patients suffering from acute or acute-on-chronic lung failure. The objective of this study was to evaluate a novel respiratory catheter that uses an impeller within the fiber bundle to enhance gas exchange efficiency, thus requiring a smaller fiber bundle and insertional size (25 Fr) and permitting simple percutaneous insertion. Bench testing of gas exchange in deionized water was used to evaluate eight impeller designs. The three best performing impeller designs were evaluated in acute studies in four calves (122 + or - 10 kg). Gas exchange increased significantly with increasing impeller rotation rate. The degree of enhancement varied with impeller geometry. The maximum gas exchange efficiency (exchange per unit surface area) for the catheter with the best performing impeller was 529 + or - 20 ml CO(2)/min/m(2) and 513 + or - 21 ml CO(2)/min/m(2) for bench and animal studies, respectively, at a rotation rate of 20,000 rpm. Absolute CO(2) exchange was 37 and 36 ml CO(2)/min, respectively. Active mixing by rotating impellers produced 70% higher gas exchange efficiency than pulsating balloon catheters. The sensitivity of gas exchange to impeller design suggests that further improvements can be made by computational fluid dynamics-based optimization of the impeller.


Asunto(s)
Órganos Artificiales , Cateterismo , Intercambio Gaseoso Pulmonar/fisiología , Respiración Artificial/instrumentación , Animales , Bovinos , Diseño de Equipo/instrumentación , Insuficiencia Respiratoria/terapia
18.
Artif Organs ; 33(6): 411-8, 2009 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-19473135

RESUMEN

Respiratory assist using intravenous catheters may be a potential therapy for patients with acute and acute-on-chronic lung failure. An important design constraint is respiratory catheter size, and new strategies are needed that enable size reduction while maintaining adequate gas exchange. Our group is currently developing a percutaneous respiratory assist catheter (PRAC) that uses a rotating bundle of hollow fiber membranes to enhance CO(2) removal and O(2) supply with increasing bundle rotation rate. In this study, particle image velocimetry (PIV) was used to analyze the fluid flow patterns and velocity fields surrounding the rotating fiber bundle of the PRAC. The goal of the study was to assess the rotational flow patterns within the context of the gas exchange enhancement that occurs with increasing fiber bundle rotation. A PRAC prototype was placed in a 1-in. internal diameter test section of an in vitro flow loop designed specifically for PIV studies. The rotation rate of the PRAC was varied between 500 and 7000 rpm, and PIV was used to determine the velocity fields in the primary (r-theta) and secondary (r-z) flow planes. The secondary flow exhibited time-varying and incoherent vortices that were consistent with the classical Taylor vortices expected for Taylor numbers (Ta) corresponding to the rotation speeds studied (2200 < Ta < 31 000). In the primary flow, the tangential velocity exhibited boundary layers of less than (1/2) mm adjacent to the fiber bundle and vessel wall. The estimated shear stress associated with the Taylor vortices was approximately 11 dyne/cm(2) at 7000 rpm and was over 10 times smaller than the shear stress in the primary flow boundary layers.


Asunto(s)
Cateterismo Venoso Central/instrumentación , Catéteres de Permanencia , Respiración Artificial/instrumentación , Velocidad del Flujo Sanguíneo , Dióxido de Carbono/metabolismo , Diseño de Equipo , Análisis de Falla de Equipo , Humanos , Membranas Artificiales , Oxígeno/metabolismo , Respiración Artificial/métodos , Estrés Mecánico
19.
ASAIO J ; 53(3): 368-73, 2007.
Artículo en Inglés | MEDLINE | ID: mdl-17515731

RESUMEN

Supplemental oxygenation and carbon dioxide removal through an intravenous respiratory assist catheter can be used as a means of treating patients with acute respiratory failure. We are beginning development efforts toward a new respiratory assist catheter with an insertional size <25F, which can be inserted percutaneously. In this study, we evaluated fiber bundle rotation as an improved mechanism for active mixing and enhanced gas exchange in intravenous respiratory assist catheters. Using a simple test apparatus of a rotating densely packed bundle of hollow fiber membranes, water and blood gas exchange levels were evaluated at various rotation speeds in a mock vena cava. At 12,000 RPM, maximum CO2 gas exchange rates were 449 and 523 mL/min per m2, water and blood, respectively, but the rate of increase with increasing rotation rate diminished beyond 7500 RPM. These levels of gas exchange efficiency are two- to threefold greater than achieved in our previous respiratory catheters using balloon pulsation for active mixing. In preliminary hemolysis tests, which monitored plasma-free hemoglobin levels in vitro over a period of 6 hours, we established that the rotating fiber bundle per se did not cause significant blood hemolysis compared with an intra-aortic balloon pump. Accordingly, fiber bundle rotation appears to be a potential mechanism for increasing gas exchange and reducing insertional size in respiratory catheters.


Asunto(s)
Dióxido de Carbono/sangre , Cateterismo Venoso Central/instrumentación , Oxígeno/sangre , Respiración Artificial/instrumentación , Insuficiencia Respiratoria/terapia , Animales , Proteínas Sanguíneas , Bovinos , Hematócrito , Hemólisis , Técnicas In Vitro , Ensayo de Materiales , Modelos Biológicos , Oxígeno/farmacocinética , Flujo Pulsátil , Rotación , Venas Cavas , Agua/metabolismo
20.
Artif Organs ; 30(9): 657-64, 2006 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-16934093

RESUMEN

To treat acute lung failure, an intravenous membrane gas exchange device, the Hattler Catheter, is currently under development. Several methods were employed to evaluate the biocompatibility of the device during preclinical testing in bovines, and potential coatings for the fibers comprising the device were screened for their effectiveness in reducing thrombus deposition in vitro. Flow cytometric analysis demonstrated that the device had the capacity to activate platelets as evidenced by significant increases in circulating platelet microaggregates and activated platelets. Thrombus was observed on 20 +/- 6% of the surface area of devices implanted for up to 53 h. Adding aspirin to the antithrombotic therapy permitted two devices to remain implanted up to 96 h with reduced platelet activation and only 3% of the surface covered with thrombus. The application of heparin-based coatings significantly reduced thrombus deposition in vitro. The results suggest that with the use of appropriate antithrombotic therapies and surface coatings the Hattler Catheter might successfully provide support for acute lung failure without thrombotic complications.


Asunto(s)
Oxigenación por Membrana Extracorpórea/instrumentación , Oxigenadores de Membrana , Activación Plaquetaria/fisiología , Agregación Plaquetaria/fisiología , Animales , Catéteres de Permanencia , Bovinos , Materiales Biocompatibles Revestidos , Diseño de Equipo , Citometría de Flujo , Ensayo de Materiales , Polipropilenos , Factores de Tiempo