Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
PLOS Glob Public Health ; 3(9): e0002389, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37725631

RESUMEN

Historically, viruses have demonstrated airborne transmission. Emerging evidence suggests the novel coronavirus (SARS-CoV-2) that causes COVID-19 also spreads by airborne transmission. This is more likely in indoor environments, particularly with poor ventilation. In the context of airborne transmission, a vital mitigation strategy for the built environment is heating, ventilation, and air conditioning (HVAC) systems. HVAC features could modify virus transmission potential. A systematic review was conducted to identify and synthesize research examining the effectiveness of filters within HVAC systems in reducing virus transmission. A comprehensive search of OVID MEDLINE, Compendex, and Web of Science Core was conducted to January 2021. Two authors were involved in study selection, data extraction, and risk of bias assessments. Study characteristics and results were displayed in evidence tables and findings were synthesized narratively. Twenty-three relevant studies showed that: filtration was associated with decreased transmission; filters removed viruses from the air; increasing filter efficiency (efficiency of particle removal) was associated with decreased transmission, decreased infection risk, and increased viral filtration efficiency (efficiency of virus removal); increasing filter efficiency above MERV 13 was associated with limited benefit in further reduction of virus concentration and infection risk; and filters with the same efficiency rating from different companies showed variable performance. Adapting HVAC systems to mitigate virus transmission requires a multi-factorial approach and filtration is one factor offering demonstrated potential for decreased transmission. For filtration to be effective, proper installation is required. Of note, similarly rated filters from different companies may offer different virus reduction results. While increasing filtration efficiency (i.e., increasing MERV rating or moving from MERV to HEPA) is associated with virus mitigation, there are diminishing returns for filters rated MERV 13 or higher. Although costs increase with filtration efficiency, they are lower than the cost of ventilation options with the equivalent reduction in transmission. Systematic review registration: PROSPERO 2020 CRD42020193968.

2.
Interact J Med Res ; 11(2): e37232, 2022 Dec 23.
Artículo en Inglés | MEDLINE | ID: mdl-36343208

RESUMEN

BACKGROUND: The COVID-19 or SARS-CoV-2 outbreak was declared a pandemic by the World Health Organization in March 2020. Almost 2 years later (early February 2022), the World Health Organization reported over 383 million cases of the disease caused by the virus, with over 5.6 million deaths worldwide. Debate regarding the routes of transmission was substantial early in the pandemic; however, airborne transmission emerged as an important consideration. Infectious airborne agents can spread within the built environment through heating, ventilation, and air-conditioning (HVAC) systems. Multiple features of HVAC systems can influence transmission (eg, ventilation, filtration, UV radiation, and humidity). Understanding how HVAC features influence airborne transmission is critical to mitigate the spread of infectious agents. OBJECTIVE: Given the airborne transmission of SARS-CoV-2, an overview of reviews was conducted to understand what is already known from the scientific literature about how virus transmission may be affected by HVAC design features in the built environment. METHODS: Ovid MEDLINE and Compendex were searched from inception to January 2021. Two reviewers independently screened the titles, abstracts, and full text of potentially relevant reviews, using a priori inclusion criteria: systematic reviews examining the effects of HVAC design features on virus transmission. Two reviewers independently assessed the methodological quality using AMSTAR2. RESULTS: Searching identified 361 citations, of which 45 (12.5%) were potentially relevant and 7 (2%) were included. Reviews were published between 2007 and 2021 and included 47 virus studies. Two earlier reviews (2007 and 2016) of 21 studies found sufficient evidence that mechanical ventilation (airflow patterns and ventilation rates) plays a role in airborne transmission; however, both found insufficient evidence to quantify the minimum mechanical ventilation requirements. One review (2017) of 9 studies examining humidity and indoor air quality found that influenza virus survival was lowest between 40% and 80% relative humidity; the authors noted that ventilation rates were a confounding variable. Two reviews (2021) examined mitigation strategies for coronavirus transmission, finding that transmission decreased with increasing temperature and relative humidity. One review (2020) identified 14 studies examining coronavirus transmission in air-conditioning systems, finding that HVAC systems played a role in virus spread during previous coronavirus outbreaks. One review (2020) examined virus transmission interventions in public ground transportation, finding ventilation and filtration to be effective. CONCLUSIONS: Seven reviews synthesizing 47 studies demonstrated a role for HVAC in mitigating airborne virus transmission. Ventilation, humidity, temperature, and filtration can play a role in the viability and transmission of viruses, including coronaviruses. Recommendations for minimum standards were not possible owing to few studies investigating a given HVAC parameter. This overview examining HVAC design features and their effects on the airborne transmission of viruses serves as a starting point for future systematic reviews and identifying priorities for primary research.

3.
PLoS One ; 17(10): e0275654, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36215321

RESUMEN

The aerosol route has been a pathway for transmission of many viruses. Similarly, recent evidence has determined aerosol transmission for SARS-CoV-2 to be significant. Consequently, public health officials and professionals have sought data regarding the role of Heating, Ventilation, and Air Conditioning (HVAC) features as a means to mitigate transmission of viruses, particularly coronaviruses. Using international standards, a systematic review was conducted to comprehensively identify and synthesize research examining the effect of humidity on transmission of coronaviruses and influenza. The results from 24 relevant studies showed that: increasing from mid (40-60%) to high (>60%) relative humidity (RH) for SARS-CoV-2 was associated with decreased virus survival; although SARS-CoV-2 results appear consistent, coronaviruses do not all behave the same; increasing from low (<40%) to mid RH for influenza was associated with decreased persistence, infectivity, viability, and survival, however effects of increased humidity from mid to high for influenza were not consistent; and medium, temperature, and exposure time were associated with inconsistency in results for both coronaviruses and influenza. Adapting humidity to mitigate virus transmission is complex. When controlling humidity as an HVAC feature, practitioners should take into account virus type and temperature. Future research should also consider the impact of exposure time, temperature, and medium when designing experiments, while also working towards more standardized testing procedures. Clinical trial registration: PROSPERO 2020 CRD42020193968.


Asunto(s)
COVID-19 , Gripe Humana , Aire Acondicionado , Calefacción , Humanos , Humedad , Aerosoles y Gotitas Respiratorias , SARS-CoV-2 , Ventilación
4.
PLoS One ; 17(4): e0266487, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35395010

RESUMEN

Respiratory viruses are capable of transmitting via an aerosol route. Emerging evidence suggests that SARS-CoV-2 which causes COVID-19 can be spread through airborne transmission, particularly in indoor environments with poor ventilation. Heating, ventilation, and air conditioning (HVAC) systems can play a role in mitigating airborne virus transmission. Ultraviolet germicidal irradiation (UVGI), a feature that can be incorporated into HVAC systems, can be used to impede the ability of viruses to replicate and infect a host. We conducted a systematic review of the scientific literature examining the effectiveness of HVAC design features in reducing virus transmission-here we report results for ultraviolet (UV) radiation. We followed international standards for conducting systematic reviews and developed an a priori protocol. We conducted a comprehensive search to January 2021 of published and grey literature using Ovid MEDLINE, Compendex, and Web of Science Core. Two reviewers were involved in study selection, data extraction, and risk of bias assessments. We presented study characteristics and results in evidence tables, and synthesized results across studies narratively. We identified 32 relevant studies published between 1936 and 2020. Research demonstrates that: viruses and bacteriophages are inactivated by UV radiation; increasing UV dose is associated with decreasing survival fraction of viruses and bacteriophages; increasing relative humidity is associated with decreasing susceptibility to UV radiation; UV dose and corresponding survival fraction are affected by airflow pattern, air changes per hour, and UV device location; and UV radiation is associated with decreased transmission in both animal and human studies. While UV radiation has been shown to be effective in inactivating viruses and reducing disease transmission, practical implementation of UVGI in HVAC systems needs to consider airflow patterns, air changes per hour, and UV device location. The majority of the scientific literature is comprised of experimental, laboratory-based studies. Further, a variety of viruses have been examined; however, there are few studies of coronaviruses and none to date of SARS-CoV-2. Future field studies of UVGI systems could address an existing research gap and provide important information on system performance in real-world situations, particularly in the context of the current COVID-19 pandemic. This comprehensive synthesis of the scientific evidence examining the impact of UV radiation on virus transmission can be used to guide implementation of systems to mitigate airborne spread and identify priorities for future research. Trial registration PROSPERO 2020 CRD42020193968.


Asunto(s)
Contaminación del Aire Interior , COVID-19 , Aire Acondicionado , Calefacción , Humanos , Pandemias/prevención & control , SARS-CoV-2 , Rayos Ultravioleta , Ventilación
5.
PLOS Glob Public Health ; 2(7): e0000552, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36962357

RESUMEN

Aerosol transmission has been a pathway for the spread of many viruses. Similarly, emerging evidence has determined aerosol transmission for Severe Acute Respiratory Syndrome coronavirus 2 (SARS-CoV-2) and the resulting COVID-19 pandemic to be significant. As such, data regarding the effect of Heating, Ventilation, and Air Conditioning (HVAC) features to control and mitigate virus transmission is essential. A systematic review was conducted to identify and comprehensively synthesize research examining the effectiveness of ventilation for mitigating transmission of coronaviruses. A comprehensive search was conducted in Ovid MEDLINE, Compendex, Web of Science Core to January 2021. Study selection, data extraction, and risk of bias assessments were performed by two authors. Evidence tables were developed and results were described narratively. Results from 32 relevant studies showed that: increased ventilation rate was associated with decreased transmission, transmission probability/risk, infection probability/risk, droplet persistence, virus concentration, and increased virus removal and virus particle removal efficiency; increased ventilation rate decreased risk at longer exposure times; some ventilation was better than no ventilation; airflow patterns affected transmission; ventilation feature (e.g., supply/exhaust, fans) placement influenced particle distribution. Few studies provided specific quantitative ventilation parameters suggesting a significant gap in current research. Adapting HVAC ventilation systems to mitigate virus transmission is not a one-solution-fits-all approach. Changing ventilation rate or using mixing ventilation is not always the only way to mitigate and control viruses. Practitioners need to consider occupancy, ventilation feature (supply/exhaust and fans) placement, and exposure time in conjunction with both ventilation rates and airflow patterns. Some recommendations based on quantitative data were made for specific scenarios (e.g., using air change rate of 9 h-1 for a hospital ward). Other recommendations included using or increasing ventilation, introducing fresh air, using maximum supply rates, avoiding poorly ventilated spaces, assessing fan placement and potentially increasing ventilation locations, and employing ventilation testing and air balancing checks. Trial registration: PROSPERO 2020 CRD42020193968.

6.
J Colloid Interface Sci ; 532: 309-320, 2018 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-30096525

RESUMEN

This paper presents a comprehensive experimental study of the effects of vertically and horizontally applied magnetic fields on the dynamics of magnetowetting and the formation of satellite droplet. Besides explaining the physics of the transient variation of different drop shape parameters, the role of a magnetic field on controlling the dynamics of spreading is also presented. Ultimately the magnetic field maneuvers the droplet spreading without altering the surface chemistry. The morphological evolution and dynamics of an impacting ferrofluid droplet has also been studied. By observing the spreading at an appropriate time scale, the contrary spreading behavior of the paramagnetic ferrofluid under the effect of magnetic field is noticed. Special attention is given to the droplet break-up and satellite droplet formation. A universal relationship is presented between the drop shape parameters before and after the impact. The destination and travel path of the satellite droplet is also analyzed in a vertical as well as horizontal magnetic field, which governs the satellite droplet merging with the already deposited parent droplet.

7.
Sci Rep ; 6: 22069, 2016 Feb 29.
Artículo en Inglés | MEDLINE | ID: mdl-26924449

RESUMEN

A practical method is reported to enhance water permeability of thin film composite (TFC) polyamide (PA) membranes by decreasing the thickness of the selective PA layer. The composite membranes were prepared by interfacial polymerization (IP) reaction between meta-phenylene diamine (MPD)-aqueous and trimesoyl chloride (TMC)-organic solvents at the surface of polyethersulfone (PES) microporous support. Several PA TFC membranes were prepared at different temperatures of the organic solution ranging from -20 °C to 50 °C. The physico-chemical and morphological properties of the synthesized membranes were carefully characterized using serval analytical techniques. The results confirmed that the TFC membranes, synthesized at sub-zero temperatures of organic solution, had thinner and smoother PA layer with a greater degree of cross-linking and wettability compared to the PA films prepared at 50 °C. We demonstrated that reducing the temperature of organic solution effectively decreased the thickness of the PA active layer and thus enhanced water permeation through the membranes. The most water permeable membrane was prepared at -20 °C and exhibited nine times higher water flux compared to the membrane synthesized at room temperature. The method proposed in this report can be effectively applied for energy- and cost-efficient development of high performance nanofiltration and reverse osmosis membranes.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA