Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Int Orthop ; 44(9): 1761-1766, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-32248265

RESUMEN

OBJECTIVE: Optimal position and fixation of the baseplate is essential for the longevity of the reverse shoulder arthroplasty (RSA) and the patient-specific instrumentation (PSI) can help the surgeon to achieve that purpose. The aim of this study was to assess the reliability of the PSI guides for the positioning of the baseplate and the fixation's screws. METHOD: Prospective study involving 35 patients operated for RSA. The PSI guides were planned and used by the senior surgeon in all cases. We compared the planned orientation (frontal and axial) of the baseplate and the screws with the post-operative CT scan. RESULTS: The mean difference between the planned measures and the post-op measures was inferior to 2.5°. The screw's length corresponded with the pre-op plan in 70% of the cases. CONCLUSION: The use of a PSI guide to position the glenoid implant in total reverse shoulder arthroplasty is reliable, reduces the risk of positioning errors and improves the quality of fixation with the screws.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Cavidad Glenoidea , Articulación del Hombro , Cavidad Glenoidea/cirugía , Humanos , Imagenología Tridimensional , Estudios Prospectivos , Reproducibilidad de los Resultados , Articulación del Hombro/diagnóstico por imagen , Articulación del Hombro/cirugía
2.
J Shoulder Elbow Surg ; 27(12): 2207-2213, 2018 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-30041944

RESUMEN

BACKGROUND: The main mechanical effect after reverse shoulder arthroplasty (RSA) is the lowering of the glenohumeral rotation center. The optimal value of the humeral lowering after RSA is still debated. The main objective of our study was to determine the lowering and medialization of the humerus and to correlate these parameters with short-term functional results. MATERIALS AND METHODS: The study included 70 patients with complete radiographic and clinical data. A multivariate analysis was used to compare the clinical and radiographic outcomes with the humeral lowering. RESULTS: The mean humeral lowering was 25.4 mm (range, 6-38 mm), and the mean medialization was 9.2 mm (range, 0-20 mm). Humeral lowering significantly influenced active forward elevation and the rate of scapular notching. DISCUSSION: The best clinical results and the lowest incidence of scapular notching were found after a lowering of more than 24 mm in our series. We recommend humeral lengthening of at least 24 mm after implanting a total reverse shoulder prosthesis.


Asunto(s)
Artroplastía de Reemplazo de Hombro/métodos , Húmero/diagnóstico por imagen , Húmero/cirugía , Articulación del Hombro/diagnóstico por imagen , Articulación del Hombro/cirugía , Anciano , Anciano de 80 o más Años , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Rotación , Lesiones del Manguito de los Rotadores/cirugía , Escápula/diagnóstico por imagen
3.
Int Orthop ; 42(1): 141-147, 2018 01.
Artículo en Inglés | MEDLINE | ID: mdl-28573515

RESUMEN

BACKGROUND: Reverse shoulder arthroplasty (RSA) requires lowering the humerus and medialisation of the centre of rotation. Several techniques based on standard X-rays are available in the literature. The aim of this study was to expose and validate a new technique for measuring these parameters. MATERIALS AND METHODS: Radiographic data of 20 patients were included. Three observers examined each X-rays three times to establish the inter- and intra-reproducibility of each technique (Jobin, Renaud and our method). RESULTS: Intra-observer reproducibility was between 0.10 and 0.94. The best intra-observer intraclass correlation coefficient (ICC) was obtained using Renaud's and our techniques. The inter-observer reproducibility was between 0.37 and 0.74. The best inter-observer ICC was obtained with our technique. DISCUSSION: We describe a reliable and reproducible method to evaluate lowering and medialisation of the humerus after RSA. This technique may allow determine the optimal threshold of lengthening after RSA.


Asunto(s)
Artroplastía de Reemplazo de Hombro/métodos , Alargamiento Óseo/métodos , Húmero/diagnóstico por imagen , Articulación del Hombro/diagnóstico por imagen , Anciano , Artroplastía de Reemplazo de Hombro/efectos adversos , Femenino , Humanos , Húmero/cirugía , Masculino , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Estudios Retrospectivos , Articulación del Hombro/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA