RESUMEN
BACKGROUND: There are limited real-world data on the clinical course of untreated coronary lesions according to their functional severity. OBJECTIVE: To evaluate the 5-year clinical outcomes of patients with revascularized lesions with fractional flow reserve (FFR) ≤ 0.8 and patients with non-revascularized lesions with FFR > 0.8. METHODS: The FFR assessment was performed in 218 patients followed for up to 5 years. Participants were classified based on FFR into ischemia group (≤ 0.8, intervention group, n = 55), low-normal FFR group (> 0.8-0.9, n = 91), and high-normal FFR group (> 0.9, n = 72). The primary endpoint was major adverse cardiac events (MACEs), a composite of death, myocardial infarction, and need for repeat revascularization. The significance level was set at 0.05; therefore, results with a p-value < 0.05 were considered statistically significant. RESULTS: Most patients were male (62.8%) with a mean age of 64.1 years. Diabetes was present in 27%. On coronary angiography, the severity of stenosis was 62% in the ischemia group, 56.4% in the low-normal FFR group, and 54.3% in the high-normal FFR group (p<0.05). Mean follow-up was 3.5 years. The incidence of MACEs was 25.5%, 13.2%, and 11.1%, respectively (p=0.037). MACE incidence did not differ significantly between the low-normal and high-normal FFR groups. CONCLUSION: Patients with FFR indicative of ischemia had poorer outcomes than those in non-ischemia groups. There was no difference in the incidence of events between the low-normal and high-normal FFR groups. Long-term studies with a large sample size are needed to better assess cardiovascular outcomes in patients with moderate coronary stenosis with FFR values between 0.8 and 1.0.
FUNDAMENTO: Existem dados limitados sobre a evolução clínica de lesões coronarianas não tratadas de acordo com sua gravidade funcional no mundo real. OBJETIVO: Este estudo teve como objetivo avaliar os resultados clínicos de até 5 anos em pacientes com lesões revascularizadas com reserva de fluxo fracionada (FFR) ≤ 0,8 e em pacientes com lesões não revascularizadas com FFR > 0,8. MÉTODOS: A avaliação pelo FFR foi realizada em 218 pacientes seguidos por até 5 anos. Os participantes foram classificados com base na FFR no grupo isquêmico (≤ 0,8, grupo intervenção, n = 55), no grupo FFR normal-baixa (> 0,8-0,9, n = 91) e no grupo FFR normal-alta (> 0,9, n = 72). O desfecho primário foram eventos cardíacos adversos maiores (ECAMs), um composto de morte, infarto do miocárdio e necessidade de nova revascularização. O nível de significância adotado neste estudo foi alfa = 0,05; deste modo, resultados com valores de p < 0,05 foram considerados estatisticamente significativos. RESULTADOS: A maioria dos participantes era do sexo masculino (62,8%) com média de idade de 64,1 anos. Diabetes estava presente em 27%. À angiografia coronariana, a gravidade da estenose avaliada foi de 62%, 56,4% e 54,3% nos grupos isquêmico, FFR normal-baixa e FFR normal-alta, respectivamente (p < 0,05). O período médio de acompanhamento foi de 3,5 anos. A incidência ECAM foi de 25,5%, 13,2% e 11,1%, respectivamente (p = 0,037). Não houve diferença na incidência de ECAM entre os grupos FFR normal-baixa e FFR normal-alta (p = NS). CONCLUSÃO: Pacientes com FFR indicativa de isquemia apresentaram piores desfechos quando comparados aos dos grupos não isquêmicos. Entre os grupos que apresentaram valores de FFR considerados normal-baixo e normal-alto, não houve diferença na incidência de eventos. Há necessidade de estudos de longo prazo e com grande número de pacientes para melhor avaliar os desfechos cardiovasculares em pacientes portadores de estenose coronariana moderada com valores de FFR entre 0,8 e 1,0.
Asunto(s)
Enfermedad de la Arteria Coronaria , Reserva del Flujo Fraccional Miocárdico , Infarto del Miocardio , Humanos , Masculino , Persona de Mediana Edad , Femenino , Enfermedad de la Arteria Coronaria/diagnóstico , Pronóstico , CorazónRESUMEN
Coordinated and harmonic (synchronous) ventricular electrical activation is essential for better left ventricular systolic function. Intraventricular conduction abnormalities, such as left bundle branch block due to artificial cardiac pacing, lead to electromechanical "dyssynchronopathy" with deleterious structural and clinical consequences. The aim of this review was to describe and improve the understanding of all the processes connecting the several mechanisms involved in the development of artificially induced ventricular dyssynchrony by cardiac pacing, most known as pacing-induced cardiomyopathy (PiCM). The chronic effect of abnormal impulse conduction and nonphysiological ectopic activation by artificial cardiac pacing is suspected to affect metabolism and myocardial perfusion, triggering regional differences in the activation/contraction processes that cause electrical and structural remodeling due to damage, inflammation, and fibrosis of the cardiac tissue. The effect of artificial cardiac pacing on ventricular function and structure can be multifactorial, and biological factors underlying PiCM could affect the time and probability of developing the condition. PiCM has not been included in the traditional classification of cardiomyopathies, which can hinder detection. This article reviews the available evidence for pacing-induced cardiovascular disease, the current understanding of its pathophysiology, and reinforces the adverse effects of right ventricular pacing, especially right ventricular pacing burden (commonly measured in percentage) and its repercussion on ventricular contraction (reflected by the impact on left ventricular systolic function). These effects might be the main defining criteria and determining mechanisms of the pathophysiology and the clinical repercussion seen on patients.
Asunto(s)
Cardiomiopatías , Insuficiencia Cardíaca , Humanos , Cardiomiopatías/etiología , Cardiomiopatías/terapia , Insuficiencia Cardíaca/etiología , Insuficiencia Cardíaca/terapia , Estimulación Cardíaca Artificial/efectos adversos , Función Ventricular Izquierda , Arritmias CardíacasRESUMEN
ABSTRACT Coordinated and harmonic (synchronous) ventricular electrical activation is essential for better left ventricular systolic function. Intraventricular conduction abnormalities, such as left bundle branch block due to artificial cardiac pacing, lead to electromechanical "dyssynchronopathy" with deleterious structural and clinical consequences. The aim of this review was to describe and improve the understanding of all the processes connecting the several mechanisms involved in the development of artificially induced ventricular dyssynchrony by cardiac pacing, most known as pacing-induced cardiomyopathy (PiCM). The chronic effect of abnormal impulse conduction and nonphysiological ectopic activation by artificial cardiac pacing is suspected to affect metabolism and myocardial perfusion, triggering regional differences in the activation/contraction processes that cause electrical and structural remodeling due to damage, inflammation, and fibrosis of the cardiac tissue. The effect of artificial cardiac pacing on ventricular function and structure can be multifactorial, and biological factors underlying PiCM could affect the time and probability of developing the condition. PiCM has not been included in the traditional classification of cardiomyopathies, which can hinder detection. This article reviews the available evidence for pacing-induced cardiovascular disease, the current understanding of its pathophysiology, and reinforces the adverse effects of right ventricular pacing, especially right ventricular pacing burden (commonly measured in percentage) and its repercussion on ventricular contraction (reflected by the impact on left ventricular systolic function). These effects might be the main defining criteria and determining mechanisms of the pathophysiology and the clinical repercussion seen on patients.
RESUMEN
Resumo Fundamento Existem dados limitados sobre a evolução clínica de lesões coronarianas não tratadas de acordo com sua gravidade funcional no mundo real. Objetivo Este estudo teve como objetivo avaliar os resultados clínicos de até 5 anos em pacientes com lesões revascularizadas com reserva de fluxo fracionada (FFR) ≤ 0,8 e em pacientes com lesões não revascularizadas com FFR > 0,8. Métodos A avaliação pelo FFR foi realizada em 218 pacientes seguidos por até 5 anos. Os participantes foram classificados com base na FFR no grupo isquêmico (≤ 0,8, grupo intervenção, n = 55), no grupo FFR normal-baixa (> 0,8-0,9, n = 91) e no grupo FFR normal-alta (> 0,9, n = 72). O desfecho primário foram eventos cardíacos adversos maiores (ECAMs), um composto de morte, infarto do miocárdio e necessidade de nova revascularização. O nível de significância adotado neste estudo foi alfa = 0,05; deste modo, resultados com valores de p < 0,05 foram considerados estatisticamente significativos. Resultados A maioria dos participantes era do sexo masculino (62,8%) com média de idade de 64,1 anos. Diabetes estava presente em 27%. À angiografia coronariana, a gravidade da estenose avaliada foi de 62%, 56,4% e 54,3% nos grupos isquêmico, FFR normal-baixa e FFR normal-alta, respectivamente (p < 0,05). O período médio de acompanhamento foi de 3,5 anos. A incidência ECAM foi de 25,5%, 13,2% e 11,1%, respectivamente (p = 0,037). Não houve diferença na incidência de ECAM entre os grupos FFR normal-baixa e FFR normal-alta (p = NS). Conclusão Pacientes com FFR indicativa de isquemia apresentaram piores desfechos quando comparados aos dos grupos não isquêmicos. Entre os grupos que apresentaram valores de FFR considerados normal-baixo e normal-alto, não houve diferença na incidência de eventos. Há necessidade de estudos de longo prazo e com grande número de pacientes para melhor avaliar os desfechos cardiovasculares em pacientes portadores de estenose coronariana moderada com valores de FFR entre 0,8 e 1,0.
Abstract Background There are limited real-world data on the clinical course of untreated coronary lesions according to their functional severity. Objective To evaluate the 5-year clinical outcomes of patients with revascularized lesions with fractional flow reserve (FFR) ≤ 0.8 and patients with non-revascularized lesions with FFR > 0.8. Methods The FFR assessment was performed in 218 patients followed for up to 5 years. Participants were classified based on FFR into ischemia group (≤ 0.8, intervention group, n = 55), low-normal FFR group (> 0.8-0.9, n = 91), and high-normal FFR group (> 0.9, n = 72). The primary endpoint was major adverse cardiac events (MACEs), a composite of death, myocardial infarction, and need for repeat revascularization. The significance level was set at 0.05; therefore, results with a p-value < 0.05 were considered statistically significant. Results Most patients were male (62.8%) with a mean age of 64.1 years. Diabetes was present in 27%. On coronary angiography, the severity of stenosis was 62% in the ischemia group, 56.4% in the low-normal FFR group, and 54.3% in the high-normal FFR group (p<0.05). Mean follow-up was 3.5 years. The incidence of MACEs was 25.5%, 13.2%, and 11.1%, respectively (p=0.037). MACE incidence did not differ significantly between the low-normal and high-normal FFR groups. Conclusion Patients with FFR indicative of ischemia had poorer outcomes than those in non-ischemia groups. There was no difference in the incidence of events between the low-normal and high-normal FFR groups. Long-term studies with a large sample size are needed to better assess cardiovascular outcomes in patients with moderate coronary stenosis with FFR values between 0.8 and 1.0.
RESUMEN
BACKGROUND: Artificial cardiac pacing by direct or indirect His bundle capture results in synchronous ventricular contraction (physiological pacing). OBJECTIVES: To compare cardiac synchronization, technical characteristics, and electronic parameters between two techniques of indirect His-bundle pacing: non-selective (NS-HBP) vs para-Hisian pacing (PHP). METHODS: The experimental intervention (between November 2019 and April 2020) consisted of implanting a DDD pacemaker in patients who had left ventricular ejection fraction (LVEF) > 35%. The resulting cardiac synchronization was compared using an electrocardiographic algorithm that analyzed QRS variation and the technical characteristics of non-selective Hisian pacing (DDD-His) and para-Hisian pacing (DDD-Var). RESULTS: Of 51 total patients (men: 28), 66.7% (34) were allocated to the DDD-Var group and 33.3% (17) to the DDD-His group. The mean ages in each group were 74 and 79 years, respectively. In the DDD-Var group, QRS variation (ventricular synchrony) improved after implantation (p < 0.001). In post-implantation ECG, 91.2% of the DDD-Var group presented a physiological pacing pattern, which was similar to the DDD-His group (88.2%; p = 0.999). The paced QRS axis was also similar (physiological) for both groups. Intraoperative fluoroscopy time (XRay) during implantation was lower for the para-Hisian technique (median 7 min in the DDD-Var group vs 21 min in the DDD-His group, p < 0.001). The mean QRS duration increased in the DDD-Var group (114.7 ms pre-implantation vs 128.2 ms post-implantation, p = 0.044). The mean post-implantation R-wave amplitude was 11.2 mV in the DDD-Var group vs 6.0 mV in the DDD-His group, p = 0.001. CONCLUSION: Para-Hisian pacing appears to indirectly recruit the His bundle, which would make this an effective and comparable strategy for physiological pacing, resulting in synchronous ventricular contraction similar to that of non-selective Hisian pacing.
FUNDAMENTO: A estimulação cardíaca artificial (ECA) por captura direta ou indireta do feixe de His resulta em contração ventricular sincrônica (ECA fisiológica). OBJETIVOS: Comparar sincronia cardíaca, características técnicas e resultados de parâmetros eletrônicos entre duas técnicas de ECA indireta do feixe de His: a não seletiva e a parahissiana. MÉTODOS: Intervenção experimental (novembro de 2019 a abril de 2020) com implante de marca-passo definitivo (MPd) DDD em pacientes com fração de ejeção ventricular esquerda > 35%. Foram comparadas a sincronia cardíaca resultante mediante algoritmo de análise eletrocardiográfica da variância espacial do QRS e as características técnicas associadas a cada método entre ECA hissiana não seletiva (DDD-His) e parahissiana (DDD-Var). RESULTADOS: De 51 pacientes (28 homens), 34 (66,7%) foram alocados no grupo DDD-Var e 17 (33,3%), no grupo DDD-His, com idade média de 74 e 79 anos, respectivamente. No grupo DDD-Var, a análise da variância espacial do QRS (índice de sincronia ventricular) mostrou melhora após o implante de MPd (p < 0,001). Ao ECG pós-implante, 91,2% dos pacientes do grupo DDD-Var mostraram padrão fisiológico de ECA, comprovando ativação similar à do DDD-His (88,2%; p = 0,999). O eixo do QRS estimulado também foi similar (fisiológico) para ambos os grupos. A mediana do tempo de fluoroscopia do implante foi de 7 minutos no grupo DDD-Var e de 21 minutos no DDD-His (p < 0,001), favorecendo a técnica parahissiana. A duração média do QRS aumentou nos pacientes do DDD-Var (114,7 ms pré-MPd e 128,2 ms pós-implante, p = 0,044). A detecção da onda R foi de 11,2 mV no grupo DDD-Var e de 6,0 mV no DDD-His (p = 0,001). CONCLUSÃO: A ECA parahissiana comprova recrutamento indireto do feixe de His, mostrando-se uma estratégia eficaz e comparável à ECA fisiológica ao resultar em contração ventricular sincrônica similar à obtida por captura hissiana não seletiva.
Asunto(s)
Fascículo Atrioventricular , Función Ventricular Izquierda , Anciano , Estimulación Cardíaca Artificial/métodos , Electrocardiografía/métodos , Humanos , Masculino , Volumen Sistólico , Resultado del Tratamiento , Función Ventricular Izquierda/fisiologíaRESUMEN
Resumo Fundamento A estimulação cardíaca artificial (ECA) por captura direta ou indireta do feixe de His resulta em contração ventricular sincrônica (ECA fisiológica). Objetivos Comparar sincronia cardíaca, características técnicas e resultados de parâmetros eletrônicos entre duas técnicas de ECA indireta do feixe de His: a não seletiva e a parahissiana. Métodos Intervenção experimental (novembro de 2019 a abril de 2020) com implante de marca-passo definitivo (MPd) DDD em pacientes com fração de ejeção ventricular esquerda > 35%. Foram comparadas a sincronia cardíaca resultante mediante algoritmo de análise eletrocardiográfica da variância espacial do QRS e as características técnicas associadas a cada método entre ECA hissiana não seletiva (DDD-His) e parahissiana (DDD-Var). Resultados De 51 pacientes (28 homens), 34 (66,7%) foram alocados no grupo DDD-Var e 17 (33,3%), no grupo DDD-His, com idade média de 74 e 79 anos, respectivamente. No grupo DDD-Var, a análise da variância espacial do QRS (índice de sincronia ventricular) mostrou melhora após o implante de MPd (p < 0,001). Ao ECG pós-implante, 91,2% dos pacientes do grupo DDD-Var mostraram padrão fisiológico de ECA, comprovando ativação similar à do DDD-His (88,2%; p = 0,999). O eixo do QRS estimulado também foi similar (fisiológico) para ambos os grupos. A mediana do tempo de fluoroscopia do implante foi de 7 minutos no grupo DDD-Var e de 21 minutos no DDD-His (p < 0,001), favorecendo a técnica parahissiana. A duração média do QRS aumentou nos pacientes do DDD-Var (114,7 ms pré-MPd e 128,2 ms pós-implante, p = 0,044). A detecção da onda R foi de 11,2 mV no grupo DDD-Var e de 6,0 mV no DDD-His (p = 0,001). Conclusão A ECA parahissiana comprova recrutamento indireto do feixe de His, mostrando-se uma estratégia eficaz e comparável à ECA fisiológica ao resultar em contração ventricular sincrônica similar à obtida por captura hissiana não seletiva.
Abstract Background Artificial cardiac pacing by direct or indirect His bundle capture results in synchronous ventricular contraction (physiological pacing). Objectives To compare cardiac synchronization, technical characteristics, and electronic parameters between two techniques of indirect His-bundle pacing: non-selective (NS-HBP) vs para-Hisian pacing (PHP). Methods The experimental intervention (between November 2019 and April 2020) consisted of implanting a DDD pacemaker in patients who had left ventricular ejection fraction (LVEF) > 35%. The resulting cardiac synchronization was compared using an electrocardiographic algorithm that analyzed QRS variation and the technical characteristics of non-selective Hisian pacing (DDD-His) and para-Hisian pacing (DDD-Var). Results Of 51 total patients (men: 28), 66.7% (34) were allocated to the DDD-Var group and 33.3% (17) to the DDD-His group. The mean ages in each group were 74 and 79 years, respectively. In the DDD-Var group, QRS variation (ventricular synchrony) improved after implantation (p < 0.001). In post-implantation ECG, 91.2% of the DDD-Var group presented a physiological pacing pattern, which was similar to the DDD-His group (88.2%; p = 0.999). The paced QRS axis was also similar (physiological) for both groups. Intraoperative fluoroscopy time (XRay) during implantation was lower for the para-Hisian technique (median 7 min in the DDD-Var group vs 21 min in the DDD-His group, p < 0.001). The mean QRS duration increased in the DDD-Var group (114.7 ms pre-implantation vs 128.2 ms post-implantation, p = 0.044). The mean post-implantation R-wave amplitude was 11.2 mV in the DDD-Var group vs 6.0 mV in the DDD-His group, p = 0.001. Conclusion Para-Hisian pacing appears to indirectly recruit the His bundle, which would make this an effective and comparable strategy for physiological pacing, resulting in synchronous ventricular contraction similar to that of non-selective Hisian pacing.