Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Gynecol Oncol ; 120(3): 353-7, 2011 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-21215440

RESUMEN

OBJECTIVE: The aim of this study was to investigate the feasibility of the sentinel lymph node (SLN) identification with SPECT/CT lymphoscintigraphy imaging in the early stage invasive cervical cancer in patients undergoing radical hysterectomy and pelvic lymphadenectomy. METHODS: Between March 2007 and June 2009, a prospective consecutive study was designed for SLN mapping. Twenty-two patients with cervical cancer FIGO stage IB1 (n=20) or stage IIA1 (n=2) underwent SLN identification with preoperative SPECT/CT and planar images (technetium-99m colloid albumin injection around the tumor) and posterior intraoperative detection with both blue dye and a handheld or laparoscopic gamma probe. Complete pelvic lymphadenectomy was performed in all cases by open (n=2) or laparoscopic (n=20) surgery. RESULTS: In the present series, a total of 35 SLN were detected with planar images and 40 SLN were identified and well located by SPECT/CT lymphoscintigraphy (median 2.0 nodes per patient). In 5/22 patients (22.7%) SPECT/CT procedure improves the number of localized SLN. Intraoperatively, 57 SLNs were identified, with a median of 3 SLNs per patient by gamma probe (a total of 53 hot nodes) and a median of 2 nodes per patient after blue dye injection (a total of 42 blue nodes). Microscopic nodal metastases (eight nodes, corresponding to four patients) were confirmed in 18.18% of cases; all these lymph nodes were previously detected as SLN. The remaining 450 nodes, including SLNs, following complete pelvic lymphadenectomy, were histologically negative. CONCLUSIONS: Sentinel lymph node detection is improved by SPECT/CT imaging because of the increased number of SLN detected and the better tridimensional anatomic location, allowing easier intra-operative detection with gamma probe and showing, in this series, a 100% negative predictive value.


Asunto(s)
Biopsia del Ganglio Linfático Centinela/métodos , Tomografía Computarizada de Emisión de Fotón Único/métodos , Tomografía Computarizada por Rayos X/métodos , Neoplasias del Cuello Uterino/patología , Adulto , Anciano , Femenino , Humanos , Persona de Mediana Edad , Estadificación de Neoplasias , Estudios Prospectivos , Neoplasias del Cuello Uterino/mortalidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA