Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Front Aging Neurosci ; 7: 133, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26388764

RESUMEN

AIMS: Pilot studies applying a humanoid robot (NAO), a pet robot (PARO) and a real animal (DOG) in therapy sessions of patients with dementia in a nursing home and a day care center. METHODS: In the nursing home, patients were assigned by living units, based on dementia severity, to one of the three parallel therapeutic arms to compare: CONTROL, PARO and NAO (Phase 1) and CONTROL, PARO, and DOG (Phase 2). In the day care center, all patients received therapy with NAO (Phase 1) and PARO (Phase 2). Therapy sessions were held 2 days per week during 3 months. Evaluation, at baseline and follow-up, was carried out by blind raters using: the Global Deterioration Scale (GDS), the Severe Mini Mental State Examination (sMMSE), the Mini Mental State Examination (MMSE), the Neuropsychiatric Inventory (NPI), the Apathy Scale for Institutionalized Patients with Dementia Nursing Home version (APADEM-NH), the Apathy Inventory (AI) and the Quality of Life Scale (QUALID). Statistical analysis included descriptive statistics and non-parametric tests performed by a blinded investigator. RESULTS: In the nursing home, 101 patients (Phase 1) and 110 patients (Phase 2) were included. There were no significant differences at baseline. The relevant changes at follow-up were: (Phase 1) patients in the robot groups showed an improvement in apathy; patients in NAO group showed a decline in cognition as measured by the MMSE scores, but not the sMMSE; the robot groups showed no significant changes between them; (Phase 2) QUALID scores increased in the PARO group. In the day care center, 20 patients (Phase 1) and 17 patients (Phase 2) were included. The main findings were: (Phase 1) improvement in the NPI irritability and the NPI total score; (Phase 2) no differences were observed at follow-up.

2.
J Alzheimers Dis ; 42(1): 325-32, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-24898637

RESUMEN

We conducted a randomized, cross-over trial to investigate the feasibility, safety, and motor effects of brain stimulation with radio electric asymmetric conveyer (REAC) technique in patients with Alzheimer's disease (AD). Neuropostural optimization (NPO) and sham protocol were administered to 60 patients from the nursing home and day care units of the Alzheimer Center Reina Sofía Foundation. The mean age was 84.1 (SD 7.9) years and 86.7% of the subjects were female. Motor measures were collected at baseline (T1), immediately (T2), seven (T3), and 11 days (T4) after treatment and, following cross-over, immediately (T5), seven (T6), and 11 (T7) days after treatment. Close safety surveillance was conducted from seven days before T1 to the end of the study (T7), with total study duration of 35 days. Wilcoxon test was utilized in the efficacy analysis, considering T1 and T5 as independent baseline assessments and using a threshold of p < 0.05 (corrected) for statistical significance. The NPO protocol was easily administered and well accepted by the participants. Axial movements improved at T3 and T4 after NPO and at T2 after sham NPO, but no significant effects were observed in axial movements in the second phase of the trial. The effects of NPO in gait performance were not consistent. There were six falls between T2 and T7, but only two of them occurred in patients who had received NPO. In light of safety and feasibility of REAC, a trial with the more intense neuropsycho-physical optimization protocol is warranted.


Asunto(s)
Enfermedad de Alzheimer/terapia , Terapia por Estimulación Eléctrica/métodos , Actividad Motora , Terapia por Radiofrecuencia , Anciano de 80 o más Años , Enfermedad de Alzheimer/fisiopatología , Encéfalo/fisiopatología , Estudios Cruzados , Centros de Día , Método Doble Ciego , Terapia por Estimulación Eléctrica/efectos adversos , Femenino , Humanos , Masculino , Casas de Salud , Ondas de Radio/efectos adversos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA