RESUMEN
The purpose of this study was to evaluate the effects of lumbar myelography on subarachnoid pressure, cardiorespiratory parameters and pressure-volume index in sheep. Eight sheep were evaluated. The animals were submitted to puncture of the cisterna magna for monitoring of subarachnoid pressure (SaP). Lumbar myelography was performed through applying Iohexol (0.4mL/kg). ToC, PAS, PAD, MAP, InspISO, FeISO, SaP and CPP were recorded immediately after anesthetic stabilization (M0), during lumbar puncture (M1), and two, four and six minutes after contrast application (M2, M3 and M4, respectively). Blood pressure initially increased, then decreased, returning to basal level, similarly observed for InspISo and FeISo. The SaP rose initially thereafter remaining stable. Despite of the effect on subarachnoid pressure, lumbar myelography can be considered safe in sheep.(AU)
O objetivo foi avaliar os efeitos da mielografia lombar na pressão subaracnóidea, parâmetros cardiorrespiratórios e índice pressão-volume em ovinos. Oito ovelhas foram avaliadas. Os animais foram submetidos à punção da cisterna magna para monitoramento da pressão subaracnoidea (SaP). A mielografia lombar foi realizada com a aplicação de Iohexol (0,4mL/kg). Os momentos estudados foram: imediatamente após a estabilização anestésica (M0), durante a punção lombar (M1), dois, quatro e seis minutos após a aplicação do contraste (M2, M3 e M4, respectivamente), para avaliar as seguintes variáveis: ToC, PAS, PAD, MAP, InspISO, FeISO, Sap e CPP. A pressão arterial aumentou inicialmente, depois diminuiu, retornando aos valores iniciais, padrão também observado para o InspISo e o FeISo. O SaP subiu inicialmente, posteriormente, permanecendo estável. A mielografia lombar, apesar de influenciar a pressão subaracnoidea, pode ser considerada segura em ovinos.(AU)
Asunto(s)
Animales , Femenino , Presión Sanguínea , Ovinos , Mielografía/efectos adversos , Presión Intracraneal , Región LumbosacraRESUMEN
The purpose of this study was to evaluate the effects of lumbar myelography on subarachnoid pressure, cardiorespiratory parameters and pressure-volume index in sheep. Eight sheep were evaluated. The animals were submitted to puncture of the cisterna magna for monitoring of subarachnoid pressure (SaP). Lumbar myelography was performed through applying Iohexol (0.4mL/kg). ToC, PAS, PAD, MAP, InspISO, FeISO, SaP and CPP were recorded immediately after anesthetic stabilization (M0), during lumbar puncture (M1), and two, four and six minutes after contrast application (M2, M3 and M4, respectively). Blood pressure initially increased, then decreased, returning to basal level, similarly observed for InspISo and FeISo. The SaP rose initially thereafter remaining stable. Despite of the effect on subarachnoid pressure, lumbar myelography can be considered safe in sheep.(AU)
O objetivo foi avaliar os efeitos da mielografia lombar na pressão subaracnóidea, parâmetros cardiorrespiratórios e índice pressão-volume em ovinos. Oito ovelhas foram avaliadas. Os animais foram submetidos à punção da cisterna magna para monitoramento da pressão subaracnoidea (SaP). A mielografia lombar foi realizada com a aplicação de Iohexol (0,4mL/kg). Os momentos estudados foram: imediatamente após a estabilização anestésica (M0), durante a punção lombar (M1), dois, quatro e seis minutos após a aplicação do contraste (M2, M3 e M4, respectivamente), para avaliar as seguintes variáveis: ToC, PAS, PAD, MAP, InspISO, FeISO, Sap e CPP. A pressão arterial aumentou inicialmente, depois diminuiu, retornando aos valores iniciais, padrão também observado para o InspISo e o FeISo. O SaP subiu inicialmente, posteriormente, permanecendo estável. A mielografia lombar, apesar de influenciar a pressão subaracnoidea, pode ser considerada segura em ovinos.(AU)
Asunto(s)
Animales , Femenino , Presión Sanguínea , Ovinos , Mielografía/efectos adversos , Presión Intracraneal , Región LumbosacraRESUMEN
ABSTRACT: The purpose of this study was to evaluate the effects of lumbar myelography on subarachnoid pressure, cardiorespiratory parameters and pressure-volume index in sheep. Eight sheep were evaluated. The animals were submitted to puncture of the cisterna magna for monitoring of subarachnoid pressure (SaP). Lumbar myelography was performed through applying Iohexol (0.4mL/kg). ToC, PAS, PAD, MAP, InspISO, FeISO, SaP and CPP were recorded immediately after anesthetic stabilization (M0), during lumbar puncture (M1), and two, four and six minutes after contrast application (M2, M3 and M4, respectively). Blood pressure initially increased, then decreased, returning to basal level, similarly observed for InspISo and FeISo. The SaP rose initially thereafter remaining stable. Despite of the effect on subarachnoid pressure, lumbar myelography can be considered safe in sheep.
RESUMO: O objetivo foi avaliar os efeitos da mielografia lombar na pressão subaracnóidea, parâmetros cardiorrespiratórios e índice pressão-volume em ovinos. Oito ovelhas foram avaliadas. Os animais foram submetidos à punção da cisterna magna para monitoramento da pressão subaracnoidea (SaP). A mielografia lombar foi realizada com a aplicação de Iohexol (0,4mL/kg). Os momentos estudados foram: imediatamente após a estabilização anestésica (M0), durante a punção lombar (M1), dois, quatro e seis minutos após a aplicação do contraste (M2, M3 e M4, respectivamente), para avaliar as seguintes variáveis: ToC, PAS, PAD, MAP, InspISO, FeISO, Sap e CPP. A pressão arterial aumentou inicialmente, depois diminuiu, retornando aos valores iniciais, padrão também observado para o InspISo e o FeISo. O SaP subiu inicialmente, posteriormente, permanecendo estável. A mielografia lombar, apesar de influenciar a pressão subaracnoidea, pode ser considerada segura em ovinos.
RESUMEN
This study aimed to develop a locking T-plate and to evaluate its mechanical properties in synthetic models. A titanium 2.7mm T-plate was designed with a shaft containing three locked screw holes and one dynamic compression hole, and a head with two locked screw holes. Forty T-shaped polyurethane blocks, and 20 T-plates were used for mechanical testing. Six bone-plate constructs were tested to failure, three in axial compression and three in cantilever bending. Fourteen bone-plate constructs were tested for failure in fatigue, seven in axial compression and seven in cantilever bending. In static testing higher values of axial compression test than cantilever bending test were observed for all variables. In axial compression fatigue testing all bone-plate constructs withstood 1,000,000 cycles. Four bone-plate constructs failure occurred before 1,000,000 cycles in cantilever bending fatigue testing. In conclusion, the locking T-plate tested has mechanical properties that offer greatest resistance to fracture under axial loading than bending forces.(AU)
O objetivo deste estudo foi desenvolver uma placa bloqueada em formato de T e avaliar as propriedades mecânicas em um modelo sintético. Uma placa-T em liga de titânio 2,7mm foi desenhada com uma haste contendo três orifícios para parafusos bloqueados e um orifício para realização de compressão dinâmica. 40 blocos de poliuretano em formato de T e 20 placas-T foram utilizados para os ensaios mecânicos. Seis montagens osso-placa foram testados até a falha, sendo três em força de compressão axial e três em flexão engastada. 14 montagens osso-placa foram testadas até a falha em fatiga, sendo 7 em força de compressão axial e 7 em flexão engastada. No teste estático, os valores mais altos foram observados em todas as variáveis no teste de compressão axial quando comparado à flexão engastada. Já nos testes de fadiga na força de compressão axial, todas as montagens osso-placa resistiram à 1000000 de ciclos. No teste de fadiga em flexão engastada, quatro montagens osso-placa falharam antes de alcançarem 1000000 de ciclos. Em conclusão, a placa-T estudada apresenta propriedades mecânicas que oferecem uma melhor resistência em estabilizar as fraturas na atuação das forças de compressão axial que nas forças de flexão.(AU)
Asunto(s)
Placas Óseas/tendencias , Fracturas Óseas/terapia , Fenómenos MecánicosRESUMEN
This study aimed to develop a locking T-plate and to evaluate its mechanical properties in synthetic models. A titanium 2.7mm T-plate was designed with a shaft containing three locked screw holes and one dynamic compression hole, and a head with two locked screw holes. Forty T-shaped polyurethane blocks, and 20 T-plates were used for mechanical testing. Six bone-plate constructs were tested to failure, three in axial compression and three in cantilever bending. Fourteen bone-plate constructs were tested for failure in fatigue, seven in axial compression and seven in cantilever bending. In static testing higher values of axial compression test than cantilever bending test were observed for all variables. In axial compression fatigue testing all bone-plate constructs withstood 1,000,000 cycles. Four bone-plate constructs failure occurred before 1,000,000 cycles in cantilever bending fatigue testing. In conclusion, the locking T-plate tested has mechanical properties that offer greatest resistance to fracture under axial loading than bending forces.(AU)
O objetivo deste estudo foi desenvolver uma placa bloqueada em formato de T e avaliar as propriedades mecânicas em um modelo sintético. Uma placa-T em liga de titânio 2,7mm foi desenhada com uma haste contendo três orifícios para parafusos bloqueados e um orifício para realização de compressão dinâmica. 40 blocos de poliuretano em formato de T e 20 placas-T foram utilizados para os ensaios mecânicos. Seis montagens osso-placa foram testados até a falha, sendo três em força de compressão axial e três em flexão engastada. 14 montagens osso-placa foram testadas até a falha em fatiga, sendo 7 em força de compressão axial e 7 em flexão engastada. No teste estático, os valores mais altos foram observados em todas as variáveis no teste de compressão axial quando comparado à flexão engastada. Já nos testes de fadiga na força de compressão axial, todas as montagens osso-placa resistiram à 1000000 de ciclos. No teste de fadiga em flexão engastada, quatro montagens osso-placa falharam antes de alcançarem 1000000 de ciclos. Em conclusão, a placa-T estudada apresenta propriedades mecânicas que oferecem uma melhor resistência em estabilizar as fraturas na atuação das forças de compressão axial que nas forças de flexão.(AU)
Asunto(s)
Titanio , Placas Óseas , Soporte de Peso , Fenómenos Mecánicos , Prótesis e ImplantesRESUMEN
OBJECTIVE--To compare ultrasonographic, CT, and surgical findings in dogs infested with giant kidney worms (Dioctophyme renale). DESIGN--Case series. ANIMALS--15 crossbred dogs infected with D renale. PROCEDURES--Immediately after ultrasonography was performed with dogs in dorsal recumbency, sequential transverse images of the abdomen were acquired with a helical CT scanner. After plain CT, contrast CT was performed with a nonionic iodinated contrast agent. Subsequently, exploratory celiotomy was performed. RESULTS--In the corticomedullary area of the right kidney of 12 dogs, ultrasonography revealed several ring-like structures with an echogenic wall and anechoic central area in the transverse plane and arrayed as bands in the longitudinal plane. Similar structures were observed in the abdominal cavity of 10 dogs. In 13 dogs, CT revealed loss of corticomedullary differentiation in the right kidney, with discrete uptake of contrast material in the periphery of the kidney, and several ring-like or elongated structures with a hyperdense wall and hypodense center. In 11 dogs, the same structures were observed free in the abdominal cavity. Surgery revealed that 13 dogs had a damaged right kidney that required nephrectomy. Parasites were found free in the abdominal cavity of 7 dogs. CONCLUSIONS AND CLINICAL RELEVANCE--Ultrasonography and CT were effective imaging methods for detecting D renale in the kidney and less effective for detecting parasites in the abdominal cavity. Care should be taken to avoid erroneously interpreting normal structures as parasites, especially in the abdominal cavity.