Front Surg ; 11: 1440042, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39296348

RESUMEN

Background: Craniosynostosis is a type of skull deformity caused by premature ossification of cranial sutures in children. Given its variability and anatomical complexity, three-dimensional visualization is crucial for effective teaching and understanding. We developed a VR database with 3D models to depict these deformities and evaluated its impact on teaching efficiency, motivation, and memorability. Methods: We included all craniosynostosis cases with preoperative CT imaging treated at our institution from 2012 to 2022. Preoperative CT scans were imported into SpectoVR using a transfer function to visualize bony structures. Measurements, sub-segmentation, and anatomical teaching were performed in a fully immersive 3D VR experience using a headset. Teaching sessions were conducted in group settings where students and medical personnel explored and discussed the 3D models together, guided by a host. Participants' experiences were evaluated with a questionnaire assessing understanding, memorization, and motivation on a scale from 1 (poor) to 5 (outstanding). Results: The questionnaire showed high satisfaction scores (mean 4.49 ± 0.25). Participants (n = 17) found the VR models comprehensible and navigable (mean 4.47 ± 0.62), with intuitive operation (mean 4.35 ± 0.79). Understanding pathology (mean 4.29 ± 0.77) and surgical procedures (mean 4.63 ± 0.5) was very satisfactory. The models improved anatomical visualization (mean 4.71 ± 0.47) and teaching effectiveness (mean 4.76 ± 0.56), with participants reporting enhanced comprehension and memorization, leading to an efficient learning process. Conclusion: Establishing a 3D VR database for teaching craniosynostosis shows advantages in understanding and memorization and increases motivation for the study process, thereby allowing for more efficient learning. Future applications in patient consent and teaching in other medical areas should be explored.

2.
Int J Comput Assist Radiol Surg ; 18(11): 1951-1959, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37296352

RESUMEN

PURPOSE: Understanding the properties and aspects of the robotic system is essential to a successful medical intervention, as different capabilities and limits characterize each. Robot positioning is a crucial step in the surgical setup that ensures proper reachability to the desired port locations and facilitates docking procedures. This very demanding task requires much experience to master, especially with multiple trocars, increasing the barrier of entry for surgeons in training. METHODS: Previously, we demonstrated an Augmented Reality-based system to visualize the rotational workspace of the robotic system and proved it helps the surgical staff to optimize patient positioning for single-port interventions. In this work, we implemented a new algorithm to allow for an automatic, real-time robotic arm positioning for multiple ports. RESULTS: Our system, based on the rotational workspace data of the robotic arm and the set of trocar locations, can calculate the optimal position of the robotic arm in milliseconds for the positional and in seconds for the rotational workspace in virtual and augmented reality setups. CONCLUSIONS: Following the previous work, we extended our system to support multiple ports to cover a broader range of surgical procedures and introduced the automatic positioning component. Our solution can decrease the surgical setup time and eliminate the need to repositioning the robot mid-procedure and is suitable both for the preoperative planning step using VR and in the operating room-running on an AR headset.

3.
Sci Rep ; 13(1): 10076, 2023 06 21.
Artículo en Inglés | MEDLINE | ID: mdl-37344554

RESUMEN

Currently, most medical image data, such as optical coherence tomography (OCT) images, are displayed in two dimensions on a computer screen. Advances in computer information technology have contributed to the growing storage of these data in electronic form. However, the data are usually processed only locally on site. To overcome such hurdles, a cyberspace virtual reality (csVR) application was validated, in which interactive OCT data were presented simultaneously to geographically distant sites (Lucerne, London, and Barcelona) where three graders independently measured the ocular csVR OCT diameters. A total of 109 objects were measured, each three times, resulting in a total of 327 csVR measurements. A minor mean absolute difference of 5.3 µm was found among the 3 measurements of an object (standard deviation 4.2 µm, coefficient of variation 0.3% with respect to the mean object size). Despite the 5 h of online work, csVR was well tolerated and safe. Digital high-resolution OCT data can be remotely and collaboratively processed in csVR. With csVR, measurements and actions enhanced with spatial audio communication can be made consistently in near real time, even if the users are situated geographically far apart. The proposed visuo-auditory framework has the potential to further boost the convenience of digital medicine toward csVR precision and collaborative medicine.


Asunto(s)
Ojo , Tomografía de Coherencia Óptica , Tomografía de Coherencia Óptica/métodos , Internet , Londres
4.
Int J Comput Assist Radiol Surg ; 15(11): 1797-1805, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-32959159

RESUMEN

PURPOSE: We present a feasibility study for the visuo-haptic simulation of pedicle screw tract palpation in virtual reality, using an approach that requires no manual processing or segmentation of the volumetric medical data set. METHODS: In a first experiment, we quantified the forces and torques present during the palpation of a pedicle screw tract in a real boar vertebra. We equipped a ball-tipped pedicle probe with a 6-axis force/torque sensor and a motion capture marker cluster. We simultaneously recorded the pose of the probe relative to the vertebra and measured the generated forces and torques during palpation. This allowed us replaying the recorded palpation movements in our simulator and to fine-tune the haptic rendering to approximate the measured forces and torques. In a second experiment, we asked two neurosurgeons to palpate a virtual version of the same vertebra in our simulator, while we logged the forces and torques sent to the haptic device. RESULTS: In the experiments with the real vertebra, the maximum measured force along the longitudinal axis of the probe was 7.78 N and the maximum measured bending torque was 0.13 Nm. In an offline simulation of the motion of the pedicle probe recorded during the palpation of a real pedicle screw tract, our approach generated forces and torques that were similar in magnitude and progression to the measured ones. When surgeons tested our simulator, the distributions of the computed forces and torques were similar to the measured ones; however, higher forces and torques occurred more frequently. CONCLUSIONS: We demonstrated the suitability of direct visual and haptic volume rendering to simulate a specific surgical procedure. Our approach of fine-tuning the simulation by measuring the forces and torques that are prevalent while palpating a real vertebra produced promising results.


Asunto(s)
Simulación por Computador , Tornillos Pediculares , Fusión Vertebral/métodos , Porcinos/cirugía , Realidad Virtual , Animales , Estudios de Factibilidad , Masculino , Movimiento (Física) , Palpación , Entrenamiento Simulado , Torque , Interfaz Usuario-Computador
5.
Sci Rep ; 10(1): 11815, 2020 07 16.
Artículo en Inglés | MEDLINE | ID: mdl-32678297

RESUMEN

Clinical science and medical imaging technology are traditionally displayed in two dimensions (2D) on a computer monitor. In contrast, three-dimensional (3D) virtual reality (VR) expands the realm of 2D image visualization, enabling an immersive VR experience with unhindered spatial interaction by the user. Thus far, analysis of data extracted from VR applications was mainly qualitative. In this study, we enhance VR and provide evidence for quantitative VR research by validating digital VR display of computed tomography (CT) data of the orbit. Volumetric CT data were transferred and rendered into a VR environment. Subsequently, seven graders performed repeated and blinded diameter measurements. The intergrader variability of the measurements in VR was much lower compared to measurements in the physical world and measurements were reasonably consistent with their corresponding elements in the real context. The overall VR measurements were 5.49% higher. As such, this study attests the ability of VR to provide similar quantitative data alongside the added benefit of VR interfaces. VR entails a lot of potential for the future research in ophthalmology and beyond in any scientific field that uses three-dimensional data.