RESUMEN
A magneto immunofluorescence assay for the detection of anti-transglutaminase antibodies (ATG2) in celiac disease was developed. The ATG2 were recognized by transglutaminase enzyme immobilized on the magnetic beads and then the immunological reaction was revealed by antibodies labeled with peroxidase. The fluorescent response of the enzymatic reaction with o-phenylenediamine and H2O2 as substrates was correlated with anti-transglutaminase titer, showing EC50 and LOD values of 1:11,600 and 1:74,500 of antibody titers, respectively. A total number of 29 sera samples from clinically confirmed cases of celiac disease and 19 negative control samples were tested by the novel magneto immunofluorescence assay. The data were submitted to the receiver-operating characteristic plot (ROC) analysis which indicated that 8.1 U was the most effective cut-off value to discriminate correctly between celiac and non-celiac patients. The immunofluorescence assay exhibited a sensitivity of 96.6%, a specificity of 89.5% and an efficiency 93.8% compared with the commercial optical ELISA kit.
Asunto(s)
Anticuerpos/sangre , Enfermedad Celíaca/diagnóstico , Técnica del Anticuerpo Fluorescente Indirecta , Proteínas de Unión al GTP/análisis , Magnetismo , Transglutaminasas/análisis , Anticuerpos/inmunología , Enfermedad Celíaca/sangre , Ensayo de Inmunoadsorción Enzimática , Enzimas Inmovilizadas/química , Enzimas Inmovilizadas/inmunología , Proteínas de Unión al GTP/inmunología , Humanos , Proteína Glutamina Gamma Glutamiltransferasa 2 , Curva ROC , Transglutaminasas/inmunologíaRESUMEN
An electrochemical magneto biosensor for the rapid determination of biotin in food samples is reported. The affinity reaction was performed on streptavidin-modified magnetic microbeads as a solid support in a direct competitive format. The biotinylated horseradish peroxidase enzyme (biotin-HRP) competes with free biotin in the sample for the binding sites of streptavidin on the magnetic microbeads. The modified magnetic beads were then easily captured by a magneto graphite-epoxy composite electrode and the electrochemical signal was based on the enzymatic activity of the HRP enzyme under the addition of H(2)O(2) as the substrate and o-phenilendiamine as cosubstrate. The response was electrochemically detected by square wave voltammetry. The limit of detection was 8.4×10(-8) mol L(--1) of biotin (20 µg L(--1)) with a dynamic range from 0.94 to 2.4×10(-7) mol L(--1). Biotin-fortified commercial dietary supplement and infant formula samples were evaluated obtaining good performances in the results. Total time of analysis was 40 min per 20 assays.