Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Int J Surg Case Rep ; 114: 109176, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38128293

RESUMEN

INTRODUCTION: Plasmacytoma is a rare hematological malignancy with a more favorable prognosis than multiple myeloma. This case report focuses on a unique solitary bone plasmacytoma (SBP) at the craniovertebral junction (CVJ), managed through surgery and radiotherapy. CASE PRESENTATION: A 50-year-old patient presented with four months of worsening neck pain and cervicobrachial neuralgia. Despite treatment and physiotherapy, symptoms persisted. Clinical examination revealed neck stiffness, with no motor or sensory deficits. Radiographs and MRI showed an infiltrating axis lesion without instability signs. A CT-guided biopsy yielded inconclusive results. To address instability and establish a diagnosis, a curettage biopsy of the C2 posterior arch was performed, followed by occipito-C4 fusion using an iliac crest graft. Histological examination confirmed SBP. Adjuvant radiotherapy and chemotherapy were administered. At four-year follow-up, there was no multiple myeloma progression, but limited neck mobility were reported, with stable fusion observed on imaging. DISCUSSION: Solitary bone plasmacytoma primarily affects the axial skeleton, with rare upper cervical spine involvement. Diagnostic criteria include histological confirmation, normal bone marrow analysis, unremarkable imaging (except for the primary lesion), and absence of end-organ damage related to lymphoplasmacytic proliferative disorders. Clinical presentation is nonspecific, and MRI is valuable for soft tissue assessment. Radiotherapy is the primary treatment, with surgery reserved for specific indications. CONCLUSION: Solitary bone plasmacytoma is a rare condition with a favorable prognosis when promptly managed. This case underscores the importance of early diagnosis and treatment to prevent recurrence or multiple myeloma progression. A multidisciplinary approach, including surgery when necessary, is crucial for optimal outcomes.

2.
Int J Surg Case Rep ; 113: 109086, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38007866

RESUMEN

INTRODUCTION AND IMPORTANCE: Surface osteosarcoma, a rare variant of osteosarcoma, poses unique challenges in diagnosis and treatment. This report discusses the application of 3D printing technology in the surgical management of a complex case involving a 27-year-old female patient with surface osteosarcoma in the proximal tibia. CASE PRESENTATION: A 27-year-old female patient presented with a progressively growing mass on her right knee, initially misdiagnosed as a benign bone tumor. Over five years, the lesion expanded from a well-corticated metaphyseal-epiphyseal outgrowth on the proximal tibia to involve the anterior tibial tuberosity. Radiological and histological evaluations confirmed well-differentiated paraosteal surface osteosarcoma. A multidisciplinary team opted for a conservative surgical approach, including resection of the anterior tibial tuberosity and patellar tendon. Precision was enhanced through 3D printing technology, which provided custom cutting guides. The reconstruction involved non-vascularized peroneus and iliac crest bone grafts. CLINICAL DISCUSSION: Accurate differentiation from benign lesions presents challenges. Achieving surgical resection with clear margins is pivotal for favourable outcomes, particularly in young patients. Chemotherapy yields limited benefits in low-grade surface osteosarcomas. Functional prognosis hinges on effective post-resection reconstruction. 3D printing technology facilitates meticulous surgical planning and guidance, enhancing the success of conservative surgical interventions. CONCLUSION: This case underscores the significance of a multidisciplinary approach, accurate diagnosis, and the integration of 3D printing technology in managing surface osteosarcomas. Conservative surgical resection, guided by precise planning and reconstruction, is critical for preserving functionality. Continued research and the adoption of innovative techniques hold promise for improving the quality of life and functional outcomes of individuals grappling with musculoskeletal tumors.

3.
Acta Orthop Belg ; 70(2): 189-92, 2004 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-15165025

RESUMEN

The authors report a case of Fielding type II acute atlanto-axial rotatory fixation (AARF). The CT scan with coronal reconstruction showed an avulsion of the apical and right alar ligament. These findings are exceptionally reported in the literature, especially concerning the apical ligament which might be a stabiliser in flexion and extension of the occipitocervical joint.


Asunto(s)
Articulación Atlantoaxoidea/lesiones , Luxaciones Articulares/rehabilitación , Tracción , Articulación Atlantoaxoidea/fisiopatología , Vértebras Cervicales/lesiones , Traumatismos Craneocerebrales/diagnóstico por imagen , Traumatismos Craneocerebrales/terapia , Estudios de Seguimiento , Humanos , Puntaje de Gravedad del Traumatismo , Luxaciones Articulares/diagnóstico por imagen , Ligamentos Articulares/lesiones , Radiografía , Rango del Movimiento Articular/fisiología , Medición de Riesgo , Negativa del Paciente al Tratamiento
4.
Tunis Med ; 82(9): 827-36, 2004 Sep.
Artículo en Francés | MEDLINE | ID: mdl-15693476

RESUMEN

On the basis of a retrospective study comprising 91 cases of femoral neck fracture treated by DHS, unrecognized screw articular penetration was observed in 9 cases (9.9%). The coxa valga (Garden I) fractures are the most interested by this complication (7 cases out of 9). With a practical purpose and to avoid remarking each time complex measurements again we found that the distance "d" separating the end of the implant from subchondral bone calculated on antero posterior and lateral views and so the angle measured on the lateral view were two criteria significantly predictive of this technical error with respectively P: 0.005 and P: 0.0005. Thus during the surgical procedure taking these two measurements after the installation of the pin guide would allow attention on the risk incurred. In case of doubt, we have changed the way of this pin before resorting to drilling and tapping.


Asunto(s)
Fracturas del Cuello Femoral/cirugía , Fijación Interna de Fracturas/efectos adversos , Clavos Ortopédicos , Tornillos Óseos , Fracturas del Cuello Femoral/diagnóstico por imagen , Fijación Interna de Fracturas/instrumentación , Fijación Interna de Fracturas/métodos , Humanos , Errores Médicos , Valor Predictivo de las Pruebas , Radiografía , Estudios Retrospectivos , Factores de Riesgo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA