Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Pol J Radiol ; 89: e281-e291, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39040560

RESUMEN

Purpose: We aimed to compare the diagnostic performance of different cone-beam computed tomography (CBCT) scan modes with and without the application of a metal artifact reduction (MAR) option under 5 different restorative materials. Material and methods: Our research was an in vitro study with 150 caries-free premolars and molars. The teeth were randomly divided into experimental (with artificially induced caries, n = 75) and control (without caries, n = 75) groups and were prepared based on 5 types of restorative materials, including conventional composites (Filtek Z250, Gradia), flow composite, glass ionomer, and amalgam. The teeth were examined under 2 CBCT scan modes (high-resolution [HIRes] and standard) with and without MAR application. Finally, the diagnostic accuracy index values (area under the receiver operating characteristic curve [AUC], sensitivity, and specificity) were calculated. Results: The AUC of standard scan mode with the MAR option was significantly lower than that of HIRes with MAR (p = 0.018) and without MAR option (p = 0.011) in detecting recurrent caries. Also, without MAR option, the diagnostic accuracy (AUC) of the standard mode was significantly lower than that of the HIRes (p = 0.020). Similar findings were observed for sensitivity and specificity. Moreover, diagnostic performance of standard and HIRes scan modes with and without MAR in the amalgam group was lower than that in other restorative material groups. Conclusions: Diagnostic performance of HIRes CBCT mode was higher than that of standard mode for recurrent caries and remained unaffected by MAR application. However, the accuracy in detecting recurrent caries was lower in the amalgam group compared with other restorative material groups.

2.
Clin Exp Dent Res ; 10(3): e884, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38798053

RESUMEN

OBJECTIVES: This study compared the effects of glazing versus polishing on mechanical, optical, and surface properties of zirconia ceramics with different translucencies. MATERIALS AND METHODS: In this in vitro study, 120 bar-shaped specimens (25 × 4 × 1.2 mm) were fabricated from three different types of zirconia with different translucencies (n = 40, DD Bio ZW, ZX2, and Cube X2). After sintering, each zirconia group was randomly divided into five subgroups of control (glazing), glazing + bur abrasion, glazing + bur abrasion + polishing with EVE Diacera® kit, glazing + bur abrasion + reglazing, and glazing + bur abrasion + polishing with EVE Diacera® kit + reglazing. The specimens underwent surface roughness, hardness, flexural strength, and translucency tests, as well as X-ray diffraction (XRD) and scanning electron microscopy (SEM) for assessment of surface topography. Data were analyzed by one-way analysis of variance, Tukey test, and Pearson test (α = .05). RESULTS: Flexural strength, surface hardness, and translucency were significantly correlated with zirconia type. ZW zirconia had significantly higher flexural strength and surface hardness and significantly lower translucency than Cube X2 and ZX2 (p < .001). Surface roughness had no significant correlation with zirconia type (p = .274). Polishing created the smoothest, and bur abrasion created the roughest surface (p < .001). Flexural strength and hardness in most experimental groups were significantly lower than in the control group (p < .001). Translucency was not significantly different in bur abrasion and polishing groups, compared with the control group; however, reglazing significantly increased the translucency (p < .001). SEM micrographs confirmed the surface roughness results. XRD showed monoclinic phase only in reglazed groups. CONCLUSION: Of different surface treatments, polishing improved the surface properties and caused the smallest change in mechanical properties of zirconia with different translucencies.


Asunto(s)
Cerámica , Pulido Dental , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Propiedades de Superficie , Circonio , Circonio/química , Pulido Dental/métodos , Cerámica/química , Dureza , Materiales Dentales/química , Resistencia Flexional , Difracción de Rayos X , Técnicas In Vitro
3.
Front Dent ; 20: 9, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37312827

RESUMEN

Objectives: This study aimed to assess the microtensile bond strength (µTBS) of etch-and-rinse (E&R), self-etch (SE), and universal adhesives to superficial and deep dentin. Materials and Methods: In this in vitro study, 40 sound third molars were randomly divided into two main groups of superficial and deep dentin. Based on our classification, superficial dentin was right beneath the deepest occlusal groove, and deep dentin was 2mm beneath the deepest occlusal groove. Each group was divided into 4 subgroups (n=20) for application of Adper Single Bond 2 (ASB), Clearfil SE Bond (CSE), and Scotchbond Universal (SBU) in E&R and SE modes along with Charisma Smart composite resin on dentin. The specimens were incubated in distilled water at 37°C for 24 hours and their µTBS was then measured. The mode of failure was determined under a stereomicroscope at ×40 magnification. Data were analyzed by one-way ANOVA (alpha=0.05). Results: The highest µTBS belonged to the superficial dentin/SBU/E&R group. The µTBS was significantly higher in superficial dentin than deep dentin for all adhesives (P=0.005). There was no significant difference in mode of failure among the groups. Conclusion: Based on the results obtained in the present study, type of bonding agent and application mode affected µTBS. In use of universal adhesive, E&R mode can improve µTBS.

4.
Front Dent ; 20: 10, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37312832

RESUMEN

Objectives: The durability of composite restorations is directly affected by the mechanical properties of the composite. The aim of this study was to evaluate the hardness and wear resistance of self-adhesive flowable composite (SAF) in comparison with conventional flowable composites. Materials and Methods: In this in vitro study, 50 composite specimens were prepared in brass molds with 10mm ×10mm ×2mm and divided into five groups (n=10). Specimens included three conventional flowable composites (Grandio flow, Filtek flow and Admira fusion flow), one self-adhering flowable composite (SAF, Vertise flow) and a microhybrid composite (filtek z250). After polishing, the micro-hardness of the specimens was measured in a Vickers hardness device, and the specimens were then subjected to 5000, 10000, 20000, 40000, 80000 and 120000 wear cycles in a wear tester. One-way ANOVA/Games-Howell, Kruskal Wallis, and Friedman tests were used for statistical analysis. The significance level was set at P<0.05. Results: The surface micro-hardness of the SAF was significantly lower than that of the microhybrid composite (P=0.01). There was no significant difference between the surface hardness of the different tested flowable composites (P>0.05). Also, the wear resistance of the studied composites was not significantly different in various cycles (P>0.05). Conclusion: Based on our results, SAF would not be an ideal substitute for conventional flowable composites in high-stress areas.

5.
Oral Radiol ; 39(4): 722-730, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37335388

RESUMEN

OBJECTIVE: The aim of this study was to compare and evaluate diagnostic accuracy of two different CBCT scan modes and digital bitewing radiography for detection of recurrent caries under five different restorative materials, and determine the relationship between the types of restorative materials. MATERIALS AND METHODS: In this in vitro study, 200 caries-free upper and lower premolars and molars were selected. A standard deep Class II cavities was created in the middle of the mesial surface of all teeth. In 100 teeth of the experimental and control groups, secondary caries was artificially demineralized. All teeth were filled with five types of restorative material including two types of conventional composite resins, flow composite resin, glass ionomer and amalgam. The teeth were imaged with high resolution (HIRes) and standard CBCT scan modes and digital bitewing. The AUC, sensitivity, specificity and areas under the ROC curve were calculated and verified through SPSS. RESULTS: CBCT technique was the best option in diagnosing recurrent caries. The diagnostic accuracy and specificity of HIRes CBCT scan mode was significantly higher than standard mode (P = 0.031) and bitewing (P = 0.029) for detection of recurrent caries, especially under composite group. There were no significant differences in accuracy value of bitewing and standard CBCT scan mode. CONCLUSION: CBCT showed higher accuracy and specificity on the detection of recurrent caries which was more accurate than bitewing radiography. The HIRes CBCT scan mode achieved the highest accuracy and performed the best in recurrent caries detection.


Asunto(s)
Tomografía Computarizada de Haz Cónico , Diente Molar , Sensibilidad y Especificidad , Radiografía de Mordida Lateral , Curva ROC , Tomografía Computarizada de Haz Cónico/métodos
6.
Dent Res J (Isfahan) ; 19: 32, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35669608

RESUMEN

Background: Considering the studies on the effects of bleaching materials on properties of dental materials, The aims of this in vitro study were to evaluate the effects of two different concentrations of bleaching agents on flexural strength and microhardness of VITA ENAMIC. Materials and Methods: In this experimental in vitro study, 30 rectangular-shaped specimens (2 mm width × 2 mm height × 12 mm length) for flexural strength and 30 specimens (5 mm width × 5 mm length × 2 mm height) for microhardness tests were prepared from VITA ENAMIC blocks 12 × 14 × 18 mm. The specimens were polished using silicon-carbide sandpapers 400, 600, 800, 1200, 2000 under flow of water for 60 s each. The prepared samples for flexural strength and microhardness were divided into 3 subgroups (n = 10): control group (C), samples bleached using Opalescence PF 15% (B15), and samples bleached with Opalescence Xtra Boost 40% (B40). Flexural strength measurement was done using a universal testing machine, and microhardness test was done using Vickers. Data were analyzed using analysis of variance and post hoc tests and P < 0.05 was considered significant. Results: The mean microhardness values of C, B15, and B40 groups were 255.46 ± 3.02, 249.86 ± 4.18, and 235.53 ± 4.61 kgf/mm2. Opalescence PF 15% and Opalescence Xtra Boost 40% affected microhardness of ENAMIC significantly (P < 0.05). The mean flexural strength values of C, B15, and B40 groups were 155.26 ± 16.13, 142.14 ± 11.52, and 133.39 ± 16.13 MPa. A significant decrease in flexural strength was found between the C and B40 groups (P = 0.007). However, the difference between flexural strength of the C and B15 groups was not significant (P > 0.05). Conclusion: Our study showed that both concentrations of bleaching agents can affect microhardness of ENAMIC. Moreover, hydrogen peroxide 40% has a negative effect on the flexural strength of ENAMIC.

7.
Front Dent ; 16(2): 136-143, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31777855

RESUMEN

OBJECTIVES: Microleakage is the most important factor responsible for the destruction of restoration margins. The aim of this study was to assess the effect of mechanical load cycling on microleakage of four types of glass ionomer cement (GIC) in comparison with a flowable composite resin. MATERIALS AND METHODS: In this in-vitro experimental study, 100 Class V cavities were prepared on the buccal and lingual surfaces of 50 intact premolars. The prepared cavities were divided into five groups of (A) Z350, (B) Equia Forte, (C) encapsulated Fuji II LC, (D) hand-mixed Fuji II LC, and (E) Ketac Molar. All the samples were thermocycled (×2,000, 5-55°C), and half of the samples in each group were load cycled. All the teeth were then immersed in 0.5% basic fuchsine for 24 hours, sectioned, and observed under a stereomicroscope. Data were analyzed with Kruskal-Wallis and Mann-Whitney-U tests. Comparison between the incisal and gingival microleakage was made with Wilcoxon test. P<0.05 was considered statistically significant. RESULTS: Load cycling and type of restorative material had a significant effect on microleakage. Gingival microleakage was significantly higher than occlusal microleakage with Equia Forte, encapsulated Fuji II LC, hand-mixed Fuji II LC, and Ketac Molar in the absence of loading, and with Z350 after loading. CONCLUSION: The sealing ability of Z350 under load cycling was better than that of Equia Forte, hand-mixed Fuji II LC, and Ketac Molar. The marginal integrity of encapsulated Fuji II LC was not significantly different than that of Z350.

8.
J Orthod Sci ; 6(1): 16-21, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28197398

RESUMEN

OBJECTIVES: To evaluate comparatively the effect of quercetin on postbleaching shear bond strength (SBS) and adhesive remnant index (ARI). MATERIALS AND METHODS: Intact maxillary premolars were divided randomly into 12 groups of 10 each: (1) bonding the bracket immediately after bleaching, (2) bonding 1 week after bleaching, (3-8) application of three experimental concentrations of quercetin (0.1%, 0.5%, and 1%) at two time durations (5 and 10 min), (9-10) application of the solvent of quercetin at two time periods (5 and 10 min), (11) application of 10% sodium ascorbate for 10 min, and (12) bonding the brackets on nonbleached teeth. Bleaching was performed using 15% carbamide peroxide gel for 5 days (6 h daily). After incubation and thermocycling, the SBS of brackets was measured. The ARI too was recorded at ×20. The data were analyzed statistically (α =0.05). RESULTS: Bleaching reduced the SBS below 10 Megapascal (MPa) level (P < 0.05) while all the postbleaching treatments (except the application of the solvent of quercetin) recovered the SBS back to values greater than 10 MPa (P < 0.05) and also back to nonbleached SBS levels (P > 0.01). All eight postbleaching treatments had rather similar efficacies (P = 0.1396). The concentration of quercetin (beta = 0.259, P = 0.042) but not its duration (beta = 0.213, P = 0.093) significantly improved its efficacy. CONCLUSION: Bleaching can weaken the bond strength of orthodontic brackets below acceptable levels. The application of quercetin or Vitamin C or delaying the bracket bonding improved the postbleaching SBS.

9.
J Dent (Tehran) ; 13(1): 29-39, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-27536326

RESUMEN

OBJECTIVES: Micromechanical retention of resin cements to alloys is an important factor affecting the longevity of metal base restorations. This study aimed to compare the bond strength and etching pattern of a newly introduced experimental etchant gel namely Nano Met Etch with those of conventional surface treatment techniques for nickel-chrome (Ni-Cr) and high noble alloys. MATERIALS AND METHODS: A total of 120 discs (8×10×15 mm) were cast with Ni-Cr (n=20), high noble BegoStar (n=50) and gold coin alloys (n=50). Their Surfaces were ground with abrasive papers. Ni-Cr specimens received sandblasting and etching. High noble alloy specimens (BegoStar and gold coin) received sandblasting, sandblasting-alloy primer, etching, etch-alloy primer and alloy primer alone. Cylindrical specimens of Panavia were bonded to surfaces using Tygon tubes. Specimens were subjected to micro-shear bond strength testing after storing at 37°C for 24 hours. RESULTS: In gold coin group, the highest bond strength was achieved after sandblasting (25.82±1.37MPa, P<0.001) and etching+alloy primer (26.60 ± 5.47 MPa, P<0.01). The lowest bond strength belonged to sandblasting+alloy primer (17.79±2.96MPa, P<0.01). In BegoStar group, the highest bond strength was obtained in the sandblasted group (38.40±3.29MPa, P<0.001) while the lowest bond strength was detected in the sandblast+ alloy primer group (15.38±2.92MPa, P<0.001). For the Ni-Cr alloy, bond strength in the etched group (20.79±2.01MPa) was higher than that in the sandblasted group (18.25±1.82MPa) (P<0.01). CONCLUSIONS: For the Ni-Cr alloy, etching was more efficient than sandblasting but for the high noble alloys, higher Au content increased the efficacy of etching.

10.
J Dent (Tehran) ; 12(10): 705-11, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-27252753

RESUMEN

OBJECTIVES: This study aimed to assess the effect of applying casein phosphopeptide- amorphous calcium phosphate (CPP-ACP) paste, casein phosphopeptide-amorphous calcium phosphate fluoride (CPP-ACPF) paste and sodium fluoride gel on surface microhardness of enamel after microabrasion. MATERIALS AND METHODS: Thirty freshly extracted human premolars were selected. All samples were subjected to hardness indentations made with the Vickers hardness machine and the average value was recorded as the initial surface microhardness. The specimens were then randomly divided into three groups (n=10) of CPP-ACPF, fluoride and CPPACP. The teeth were micro-abraded with Opalustre. Microhardness test was performed to assess the post-abrasion hardness. Three remineralization modalities were performed on samples of each group. The enamel surface microhardness measurements were performed. To compare the difference between groups, the rehardening and softening values were defined. One-way ANOVA and Tukey's post hoc test at a significance level of 5% were used for statistical analysis. RESULTS: The mean microhardness value (MMV) had a significant decrease after microabrasion from baseline. The MMV had a significant increase after remineralization in all groups. The MMV of CPP-ACPF group was significantly more than that of fluoride group (P=0.027). The rehardening value of fluoride group was significantly more than that of other groups (P<0.001). CONCLUSION: All the remineralizing agents were effective for rehardening the enamel after microabrasion. The CPP-ACP and CPP-ACPF pastes are effective, but to a lesser extent than neutral sodium fluoride gel in remineralizing enamel surface. Incorporation of fluoride to CPP-ACP formulation does not provide any additional remineralizing potential.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA