RESUMEN
Introduction-The dynamics of SARS-CoV-2 shedding and replication in humans remain incompletely understood. Methods-We analyzed SARS-CoV-2 shedding from multiple sites in individuals with an acute COVID-19 infection by weekly sampling for five weeks in 98 immunocompetent and 25 immunosuppressed individuals. Samples and culture supernatants were tested via RT-PCR for SARS-CoV-2 to determine viral clearance rates and in vitro replication. Results-A total of 2447 clinical specimens were evaluated, including 557 nasopharyngeal swabs, 527 saliva samples, 464 urine specimens, 437 anal swabs and 462 blood samples. The SARS-CoV-2 genome sequences at each site were classified as belonging to the B.1.128 (ancestral strain) or Gamma lineage. SARS-CoV-2 detection was highest in nasopharyngeal swabs regardless of the virus strain involved or the immune status of infected individuals. The duration of viral shedding varied between clinical specimens and individual patients. Prolonged shedding of potentially infectious virus varied from 10 days up to 191 days, and primarily occurred in immunosuppressed individuals. Virus was isolated in culture from 18 nasal swab or saliva samples collected 10 or more days after onset of disease. Conclusions-Our findings indicate that persistent SARS-CoV-2 shedding may occur in both competent or immunosuppressed individuals, at multiple clinical sites and in a minority of subjects is capable of in vitro replication.
Asunto(s)
COVID-19 , Humanos , COVID-19/diagnóstico , SARS-CoV-2/genética , Prueba de COVID-19 , Manejo de Especímenes , Esparcimiento de Virus , ARN Viral/genéticaRESUMEN
COVID-19 disease is spread worldwide and diagnostic techniques have been studied in order to contain the pandemic. Immunochromatographic (IC) assays are feasible and a low-cost alternative especially in low and middle-income countries, which lack structure to perform certain diagnostic techniques. Here we evaluate the sensitivity and specificity of eleven different IC tests in 145 serum samples from confirmed cases of COVID-19 using RT-PCR and 100 negative serum samples from blood donors collected in February 2019. We also evaluated the cross-reactivity with dengue using 20 serum samples from patients with confirmed diagnosis for dengue collected in early 2019 through four different tests. We found high sensitivity (92%), specificity (100%) and an almost perfect agreement (Kappa 0.92) of IC assay, especially when we evaluated IgG and IgM combined after 10 days from the onset of symptoms with RT-PCR. However, we detected cross-reactivity between dengue and COVID-19 mainly with IgM antibodies (5 to 20% of cross-reaction) and demonstrated the need for better studies about diagnostic techniques for these diseases.
Asunto(s)
COVID-19 , Dengue , Anticuerpos Antivirales , COVID-19/diagnóstico , Dengue/diagnóstico , Humanos , Inmunoensayo/métodos , Inmunoglobulina G , Inmunoglobulina M , SARS-CoV-2 , Sensibilidad y EspecificidadRESUMEN
ABSTRACT COVID-19 disease is spread worldwide and diagnostic techniques have been studied in order to contain the pandemic. Immunochromatographic (IC) assays are feasible and a low-cost alternative especially in low and middle-income countries, which lack structure to perform certain diagnostic techniques. Here we evaluate the sensitivity and specificity of eleven different IC tests in 145 serum samples from confirmed cases of COVID-19 using RT-PCR and 100 negative serum samples from blood donors collected in February 2019. We also evaluated the cross-reactivity with dengue using 20 serum samples from patients with confirmed diagnosis for dengue collected in early 2019 through four different tests. We found high sensitivity (92%), specificity (100%) and an almost perfect agreement (Kappa 0.92) of IC assay, especially when we evaluated IgG and IgM combined after 10 days from the onset of symptoms with RT-PCR. However, we detected cross-reactivity between dengue and COVID-19 mainly with IgM antibodies (5 to 20% of cross-reaction) and demonstrated the need for better studies about diagnostic techniques for these diseases.
RESUMEN
Mobile phones (MPs) have become an important work tool around the world including in hospitals. We evaluated whether SARS-CoV-2 can remain on the surface of MPs of first-line healthcare workers (HCW) and also the knowledge of HCWs about SARS-CoV-2 cross-transmission and conceptions on the virus survival on the MPs of HCWs. A cross-sectional study was conducted in the COVID-19 Intensive Care Unit of a teaching hospital. An educational campaign was carried out on cross-transmission of SARS-CoV-2, and its permanence in fomites, in addition to the proper use and disinfection of MPs. Herewith an electronic questionnaire was applied including queried conceptions about hand hygiene and care with MP before and after the pandemic. The MPs were swabbed with a nylon FLOQ Swab™, in an attempt to increase the recovery of SARS-CoV-2. All MP swab samples were subjected to SARS-CoV-2 RT-PCR; RT-PCR positive samples were subjected to viral culture in Vero cells (ATCC® CCL-81™). Fifty-one MPs were swabbed and a questionnaire on hand hygiene and the use and disinfection of MP was applied after an educational campaign. Most HCWs increased adherence to hand hygiene and MP disinfection during the pandemic. Fifty-one MP swabs were collected and two were positive by RT-PCR (4%), with Cycle threshold (Ct ) values of 34-36, however, the cultures of these samples were negative. Although most HCWs believed in the importance of cross-transmission and increased adherence to hand hygiene and disinfection of MP during the pandemic, SARS-CoV-2 RNA was detected in MPs. Our results suggest the need for a universal policy in infection control guidelines on how to care for electronic devices in hospital settings.
Asunto(s)
COVID-19 , Teléfono Celular , Animales , Chlorocebus aethiops , Estudios Transversales , Hospitales , Humanos , ARN Viral , SARS-CoV-2 , Células VeroRESUMEN
This study assessed the disinfection using 70% ethanol; H2O2-quaternary ammonium salt mixture; 0.1% sodium hypochlorite and autoclaving of four 3D-printed face shields with different designs, visor materials; and visor thickness (0.5-0.75 mm). We also investigated their clinical suitability by applying a questionnaire to health workers (HW) who used them. Each type of disinfection was done 40 times on each type of mask without physical damage. In contrast, autoclaving led to appreciable damage.
Asunto(s)
COVID-19/prevención & control , Desinfectantes/farmacología , Desinfección/métodos , Equipo de Protección Personal/virología , Impresión Tridimensional , SARS-CoV-2 , COVID-19/epidemiología , Recolección de Datos , Diseño de Equipo , Etanol/farmacología , Personal de Salud , Humanos , Peróxido de Hidrógeno/farmacología , Hipoclorito de Sodio/farmacologíaRESUMEN
OBJECTIVES: We evaluated a rapid chromatographic immunoassay (IgG/IgM antibodies) and an ELISA assay to diagnose COVID-19 in patient sat two Brazilian hospitals. METHODS: A total of 122 subjects with COVID-19 were included: 106 SARS-COV-2 RT-PCR-positive patients and 16 RT-PCR-negative patients with symptoms and chest computed tomography (CT) consistent with COVID-19. Ninety-six historical blood donation samples were used as controls. Demographic and clinical characteristics were retrieved from electronic records. Sensitivity and specificity were calculated, as were their 95% binomial confidence intervals using the Clopper-Pearson method. All analyses were performed in R version 3.6.3. RESULTS: The sensitivity of the chromatographic immunoassay in all RT-PCR-positive patients, irrespective of the timing of symptom onset, was 85.8% (95% binomial CI 77.7% to 91.9%). This increased with time after symptom onset, and at >14 days was 94.9% (85.9% to 98.9%). The specificity was 100% (96.4% to 100%). 15/16 (94%) RT- PCR-negative cases tested positive. The most frequent comorbidities were hypertension and diabetes mellitus and the most frequent symptoms were fever, cough, and dyspnea. All RT-PCR-negative patients had pneumonia. The most frequent thoracic CT findings were ground glass changes (nâ¯=â¯11, 68%), which were bilateral in 9 (56%) patients, and diffuse reticulonodular infiltrates (nâ¯=â¯5, 31%). CONCLUSIONS: The COVID-19 rapid chromatographic immunoassay evaluated in this study had a high sensitivity and specificity using plasma, particularly after 14 days from symptom onset. ELISA and qualitative rapid chromatographic immunoassays can be used for the diagnosis of RT-PCR-negative patients.
Asunto(s)
Anticuerpos Antivirales/sangre , Cromatografía , Infecciones por Coronavirus/diagnóstico , Inmunoensayo , Neumonía Viral/diagnóstico , Adulto , Anciano , Anciano de 80 o más Años , Betacoronavirus , Brasil , COVID-19 , Prueba de COVID-19 , Técnicas de Laboratorio Clínico , Infecciones por Coronavirus/inmunología , Femenino , Hospitalización/estadística & datos numéricos , Humanos , Inmunoglobulina G/sangre , Masculino , Persona de Mediana Edad , Pandemias , Neumonía Viral/inmunología , Estudios Prospectivos , SARS-CoV-2 , Sensibilidad y Especificidad , Adulto JovenRESUMEN
BACKGROUND: The use of combined antibiotic therapy has become an option for infections caused by multidrug-resistant (MDR) bacteria. The time-kill (TK) assay is considered the gold standard method for the evaluation of in vitro synergy, but it is a time-consuming and expensive method. The purpose of this study was to evaluate two methods for testing in vitro antimicrobial combinations: the disk diffusion method through disk approximation (DA) and the agar gradient diffusion method via the MIC:MIC ratio. The TK assay was included as the gold standard. MDR Gram-negative clinical isolates (n = 62; 28 Pseudomonas aeruginosa, 20 Acinetobacter baumannii, and 14 Serratia marcescens) were submitted to TK, DA, and MIC:MIC ratio synergy methods. RESULTS: Overall, the agreement between the DA and TK assays ranged from 20 to 93%. The isolates of A. baumannii showed variable results of synergism according to TK, and the calculated agreement was statistically significant in this species against fosfomycin with meropenem including colistin-resistant isolates. The MIC:MIC ratiometric agreed from 35 to 71% with TK assays. The kappa test showed good agreement for the combination of colistin with amikacin (K = 0.58; P = 0.04) among the colistin-resistant A. baumannii isolates. CONCLUSIONS: The DA and MIC:MIC ratiometric methods are easier to perform and might be a more viable tool for clinical microbiology laboratories.