Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Materials (Basel) ; 16(8)2023 Apr 10.
Artículo en Inglés | MEDLINE | ID: mdl-37109834

RESUMEN

Pulsed thermography is a nondestructive method commonly used to explore anomalies in composite materials. This paper presents a procedure for the automated detection of defects in thermal images of composite materials obtained with pulsed thermography experiments. The proposed methodology is simple and novel as it is reliable in low-contrast and nonuniform heating conditions and does not require data preprocessing. Nonuniform heating correction and the gradient direction information combined with a local and global segmentation phase are used to analyze carbon fiber-reinforced plastic (CFRP) thermal images with Teflon inserts with different length/depth ratios. Additionally, a comparison between the actual depths and estimated depths of detected defects is performed. The performance of the nonuniform heating correction proposed method is superior to that obtained on the same CFRP sample analyzed with a deep learning algorithm and the background thermal compensation by filtering strategy.

2.
Data Brief ; 32: 106313, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-32995401

RESUMEN

This paper presents a thermal imaging dataset from composite material samples (carbon and glass fiber reinforced plastic) that were inspected by pulsed thermography with the goal of detecting and characterizing subsurface defective zones (Teflon inserts representing delaminations between plies). The pulsed thermography experiment was applied to 6 academic plates (inspected from both sides) all having the dimensions of 300 mm x 300 mm x 2 mm and same distribution of defects but made of different materials: three plates on carbon fiber-reinforced plastic (CFRP) and three plates made on glass fiber reinforced plastic (GFRP) specimens with three different geometries: planar, curved and trapezoidal. Each plate contains 25 inserts having length/depth ratios between 1.7 and 75. Two FX60 BALCAR photographic flashes (6.2 kJ per flash) were used to generate the heat pulse (2 ms duration), an X6900 FLIR infrared camera using ResearchIR software to record the thermal images and a custom-built software/control unit to synchronize data recording with pulse generation. Finally, the dataset proposed consists of 12 sequences of approximately 2000 images of 512 × 512 pixels each.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA