Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-39033331

RESUMEN

BACKGROUND: Although covered stents (CS) represent a potentially life-saving intervention for coronary perforation (CAP), their application has expanded to other contexts, including coronary aneurysms (CAA). However, data regarding mid- and long-term outcomes of CS in these settings scenarios remains limited. AIMS: This meta-analysis aims to evaluate major adverse cardiac events (MACE) from discharge through long-term follow-up in patients undergoing percutaneous coronary intervention with the new generation polyurethane-covered cobalt-chromium PK Papyrus CS. METHODS: We conducted a meta-analysis of data from three observational trials that included long-term follow-up of patients who underwent PK Papyrus CS implantation: Papyrus-Spain, SOS PK Papyrus, and PAST-PERF registry. RESULTS: 332 patients underwent PK Papyrus CS implantation, 236 (71.1%) for CAP, 70 (21.1%) for CAA and 26 (7.8%) for other indications. After a mean follow-up of 16.2 months, the MACE was 14.3%, with Target Lesion Revascularization (TLR) being the most frequent (8.5%), followed by stent thrombosis (ST), 3.3% and cardiac death (CD), 2.6%. Comparing CAP and CAA subgroups, the MACE rate in CAA was significantly higher than CAP (21.4% vs 9.7%, p < 0.01), primary driven by ST (CAA: 8.6% vs CAP: 1.3%; p = 0.0015). CONCLUSIONS: The clinical outcomes following PK Papyrus CS implantation are deemed acceptable, considering the challenging scenarios and the existing alternative treatments. However, MACE rates in patients with CAA who received Papyrus PK CS were significantly higher than in those with CAP, underscoring the importance of meticulous patient selection and optimization of CS in these complex patients and coronary anatomies.

2.
Sci Rep ; 14(1): 3790, 2024 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-38360982

RESUMEN

We uncover new features on the study of a two-level atom interacting with one of two cavities in a coherent superposition. The James-Cummings model is used to describe the atom-field interaction and to study the effects of quantum indefiniteness on such an interaction. We show that coherent control of the two cavities in an undefined manner allows novel possibilities to manipulate the atomic dynamics on demand which are not achievable in the conventional way. In addition, it is shown that the coherent control of the atom creates highly entangled states of the cavity fields taking a Bell-like or Schrödinger-cat-like state form. Our results are a step forward to understand and harness quantum systems in a coherent control, and open a new research avenue in the study of atom-field interaction exploiting quantum indefiniteness.

3.
Int J Mol Sci ; 24(13)2023 Jun 29.
Artículo en Inglés | MEDLINE | ID: mdl-37446061

RESUMEN

Fenna-Mathews-Olson complexes participate in the photosynthetic process of Sulfur Green Bacteria. These biological subsystems exhibit quantum features which possibly are responsible for their high efficiency; the latter may comprise multipartite entanglement and the apparent tunnelling of the initial quantum state. At first, to study these aspects, a multidisciplinary approach including experimental biology, spectroscopy, physics, and math modelling is required. Then, a global computer modelling analysis is achieved in the computational biology domain. The current work implements the Hierarchical Equations of Motion to numerically solve the open quantum system problem regarding this complex. The time-evolved states obtained with this method are then analysed under several measures of entanglement, some of them already proposed in the literature. However, for the first time, the maximum overlap with respect to the closest separable state is employed. This authentic multipartite entanglement measure provides information on the correlations, not only based on the system bipartitions as in the usual analysis. Our study has led us to note a different view of FMO multipartite entanglement as tiny contributions to the global entanglement suggested by other more basic measurements. Additionally, in another related trend, the initial state, considered as a Förster Resonance Energy Transfer, is tracked using a novel approach, considering how it could be followed under the fidelity measure on all possible permutations of the FMO subsystems through its dynamical evolution by observing the tunnelling in the most probable locations. Both analyses demanded significant computational work, making for a clear example of the complexity required in computational biology.


Asunto(s)
Proteínas Bacterianas , Chlorobi , Proteínas Bacterianas/química , Complejos de Proteína Captadores de Luz/metabolismo , Transferencia Resonante de Energía de Fluorescencia , Simulación por Computador , Teoría Cuántica
6.
Catheter Cardiovasc Interv ; 98(5): 874-881, 2021 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-33085150

RESUMEN

OBJECTIVES: To evaluate the rate of procedural success and long-term outcomes of the PK Papyrus (PKP) covered stent (CS). BACKGROUND: CS are essential in the treatment of coronary artery perforation (CAP). They have also been used to treat coronary artery aneurysms. Limited evidence is available on clinical outcomes with the PKP. METHODS: This was a multicenter, observational, retrospective, and prospective study. Consecutive patients undergoing intentional PKP implantation in 22 centers in France were included. The primary endpoint was the rate of procedural success. Secondary endpoints included rates of death, myocardial infarction (MI), target lesion revascularization (TLR), in-stent restenosis (ISR), and stent thrombosis (ST). RESULTS: Data from 130 patients were analyzed (mean age 72.5 ± 10.5 years; 71% men). The main indication for PKP was CAP, in 84 patients (65%). Delivery success was achieved in 95% and procedural success in 91%. During the in-hospital stay, 15 patients died (12%) and 7 (5%) presented with ST. Data from 127 patients were available at 19.2 ± 12.8 month follow-up. Thirty-three patients died (26%), 15 (12%) had an MI and 21 (17%) presented with TLR. TLR was due to ISR in 12 patients (9%), 10 had definite ST (8%) and 1 patient for stent under-expansion. CONCLUSIONS: The principal indication for PKP was CAP. PKP had high rates of delivery and procedural success. At long-term follow-up, there was a high rate of TLR, mainly due to ISR and ST. These results are consistent with previously reported data in these clinical settings.


Asunto(s)
Reestenosis Coronaria , Intervención Coronaria Percutánea , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Diseño de Prótesis , Sistema de Registros , Estudios Retrospectivos , Stents , Resultado del Tratamiento
8.
Am J Cardiol ; 123(7): 1120-1126, 2019 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-30709598

RESUMEN

Thrombocytopenia after transcatheter aortic valve implantation (TAVI) is common and has been related to worse clinical outcomes. Comparison of platelet kinetics among different types of valves is limited. Our objectives were to analyze the differences in drop platelet count (DPC) between balloon-expandable valves (BEVs) and self-expanding valves and their prognostic implications after TAVI. Patients who underwent transfemoral TAVI from 2008 to 2016 were included. Exclusion criteria were severe baseline thrombocytopenia and periprocedural death. Postprocedural platelet counts were collected. Two groups were created: DPC ≤30 and DPC >30%. Valve Academic Research Consortium-2 criteria were used to define outcomes. Study population included 609 patients (age 84.7 ± 6.0, 46.6% males). The mean DPC was 32.5 ± 13.9%. The DPC was higher in the BEV arm (33.9 ± 14.2 vs 30.7 ± 13.4%, p = 0.006), and the nadir was reached later in comparison to the self-expanding valve arm (3.0 ± 1.3 vs 2.5 ± 1.1 days, p <0.001). After multivariable analysis, the use of BEV, known coronary artery disease, and left ventricle ejection fraction were the factors associated with a higher rate of DPC >30%. At 30 days, the DPC >30% was related with a higher rate of life-threatening and/or major bleeding (6.8 vs 2.1%, p = 0.009) and death (3.5 vs 0.8%, p = 0.036). At 1 year, the difference in mortality disappeared. In conclusion, in this cohort of patients, the use of BEV seems to be associated with a higher risk of DPC after TAVI. A DPC ≥30% was related with increased risk of life-threatening and/or major bleeding and death at 30 days. Larger and prospective studies are needed to understand this phenomenon.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas , Complicaciones Posoperatorias/epidemiología , Trombocitopenia/epidemiología , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/diagnóstico , Femenino , Estudios de Seguimiento , Francia/epidemiología , Humanos , Incidencia , Masculino , Recuento de Plaquetas , Complicaciones Posoperatorias/sangre , Complicaciones Posoperatorias/etiología , Estudios Prospectivos , Diseño de Prótesis , Tasa de Supervivencia/tendencias , Trombocitopenia/sangre , Trombocitopenia/etiología
9.
Catheter Cardiovasc Interv ; 93(7): 1344-1351, 2019 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-30244545

RESUMEN

BACKGROUND: Thrombocytopenia after transcatheter aortic valve implantation (TAVI) is common and has been related to higher mortality and major complications. No comparison between balloon-expandable (BEV) and self-expanding valves (SEV) regarding drop platelet count (DPC) has been reported to date. The objectives of this study were to analyze the differences in DPC between BEVs or SEVs and their prognostic implications in clinical outcomes. METHODS: We retrospectively analyzed patients undergoing TAVI. Platelet counts after TAVI were collected. Two groups were created: DPC ≤ 30% and DPC > 30%. VARC-2 criteria were used to define outcomes. RESULTS: Study population was composed of 195 patients (age 77.5 ± 6.7, 57.4% males). All of them but one experienced DPC (mean DPC 31.9 ± 15.3%). DPC was significantly higher among the patients treated with BEV compared to those treated with SEV (36.3 ± 15.1% vs 27.7 ± 14.4, P < 0.001). After multivariate analysis, the use of BEV was independently associated with a higher rate of DPC > 30% (67.4% vs 36.0%; OR 3.4; 95% CI, 1.42-8.16). At 30 days, the DPC > 30% was associated with a higher rate of life-threatening/major bleeding, major vascular complications, in-hospital sepsis and mortality. At one year, there were no statistically significant differences in the mortality rate between groups (6.35% vs 10.0%, HR 1.54; 95% CI, 0.56-4.25). CONCLUSIONS: In this study, the use of BEV was associated with a higher risk of DPC after TAVI. A DPC rate > 30% was associated with an increased risk of major complications at 30 days.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas , Trombocitopenia/etiología , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/sangre , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Femenino , Mortalidad Hospitalaria , Humanos , Masculino , Recuento de Plaquetas , Diseño de Prótesis , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Índice de Severidad de la Enfermedad , España , Trombocitopenia/sangre , Trombocitopenia/diagnóstico , Trombocitopenia/mortalidad , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
10.
J Heart Valve Dis ; 27(1): 114-116, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-30560609

RESUMEN

A patient with ischemic myocardiopathy who had undergone resynchronization therapy was admitted to the authors' institution with progressive dyspnea. Echocardiography demonstrated a left ventricular ejection fraction (LVEF) of 25%, with a massive mitral regurgitation (MR) secondary to anterior leaflet prolapse and posterior leaflet restriction. Despite intensive medical treatment, the patient developed cardiogenic shock and required mechanical ventilation, inotropic support and intra-aortic balloon pumping. The patient was rejected for surgery due to the high operative risk, but subsequently underwent a successful percutaneous repair with two MitraClip® devices. Immediately after the intervention there was a progressive improvement that allowed the patient to be discharged, such that the clinical outcome was favorable at the six-month follow up (NYHA class II/IV). This case report describes the benefits of minimally invasive therapy in selected patients who are at very high surgical risk and who, despite being in a critical condition and with low LVEF, experience an outstanding clinical improvement following the resolution of a massive MR.


Asunto(s)
Insuficiencia de la Válvula Mitral/cirugía , Válvula Mitral/cirugía , Choque Cardiogénico/cirugía , Enfermedad Aguda , Humanos , Insuficiencia de la Válvula Mitral/complicaciones , Insuficiencia de la Válvula Mitral/fisiopatología , Choque Cardiogénico/etiología , Choque Cardiogénico/fisiopatología , Volumen Sistólico , Resultado del Tratamiento
13.
J Interv Cardiol ; 31(5): 617-623, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-29808511

RESUMEN

OBJECTIVES: To compare outcomes in patients receiving polytetrafluoroethylene (PTFE) and polyurethane (PL) covered stents (CS) after coronary artery perforation (CAP). BACKGROUND: The prognosis of CAP has improved with the advent of CSs. Information is scarce about the outcomes of new-generation CSs. METHODS: Sixty-one patients were treated with CSs in a 5-years period (age = 77 ± 8.75% males). Procedural and clinical data were retrospectively collected. The primary endpoint was procedural success. Secondary endpoints included death and major adverse cardiac events (MACE) defined as a composite of death, myocardial infarction, target vessel, and lesion revascularization and need for surgical repair). RESULTS: Twenty-two (36%) received PL-CSs and 39 (65%) PTFE-CSs. There were no differences in procedural success (86% vs 69%, P = 0.216). Time to deliver was shorter with PL-CS despite larger length of stents (8[11] vs 15[16] min, P = 0.001; 20[5] vs 16[3] mm, P < 0.001). This group had lower rate of pericardial effusion and cardiac arrest (41% vs 72%, P = 0.028; 5% vs 26%, P = 0.045). At 1-year follow-up, MACE rates were similar (58% vs 56%, P = 1.000) with atrend toward TVR in the PL-CS arm (21% vs 5%, P = 0.083). No differences were found in mortality (26% vs 41%, P = 0.385). Each group had 1 stent thrombosis and in-stent restenosis trended higher in the PL-CS group (12% vs 3%, P = 0.223). CONCLUSIONS: Time to deliver was shorter with the PL-CS and resulted in lower rate of pericardial effusion and cardiac arrest. However, there were no significant differences in procedural success and 1-year follow-up MACE in patients treated with PL-CS or PTFE-CS.


Asunto(s)
Implantación de Prótesis Vascular/instrumentación , Vasos Coronarios , Stents Liberadores de Fármacos/efectos adversos , Intervención Coronaria Percutánea/efectos adversos , Politetrafluoroetileno/uso terapéutico , Poliuretanos/uso terapéutico , Herida Quirúrgica/cirugía , Lesiones del Sistema Vascular , Anciano , Anciano de 80 o más Años , Materiales Biocompatibles Revestidos/uso terapéutico , Vasos Coronarios/lesiones , Vasos Coronarios/cirugía , Femenino , Humanos , Masculino , Diseño de Prótesis , Estudios Retrospectivos , Resultado del Tratamiento , Lesiones del Sistema Vascular/etiología , Lesiones del Sistema Vascular/cirugía
14.
J Interv Cardiol ; 31(4): 465-470, 2018 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-29372576

RESUMEN

OBJECTIVES: To analyze the procedural and long-term outcomes of the use of rotational atherectomy (RA) in underexpanded stents in our cohort and to provide an overview of currently available data on this technique. BACKGROUND: Stent underexpansion (SU) has been related to stent thrombosis and restenosis. RA has been used to treat undilatable SU as a bail-out strategy with encouraging results. METHODS: This is an observational, single-center study. We included patients who underwent stentablation between 2013 and 2017. Baseline demographics, procedural results, in-hospital major adverse cardiac events (MACE), and long-term follow-up MACE were retrospectively collected. RESULTS: A total of 11 patients (90.9% males, mean age 65.4 ± 18.6) were included in this study. Median left ventricle ejection fraction was 53.5% [46.2-55]. Median calculated Syntax score was 16 [9-31] and 45.5% of patients were admitted for acute coronary syndrome. Radial approach was used in 63.6% of cases. Most patients only required one burr (45% used a 1.5 mm diameter burr) during the intervention. Procedural success was achieved in 90.9% of the cases. Acute lumen gain was 42.7% [30.7-61.49]. There were no in-hospital deaths or MACE. At a median follow-up of 26 months, only one patient (9.1%) suffered MACE in the context of acute coronary syndrome, and two patients (18.2%) required non-target lesion revascularization. No deaths were reported. CONCLUSIONS: RA of under expanded stents is a feasible option with a high rate of procedural success. At long-term follow-up, all of them were alive and 90.9% of patients remained free from MACE.


Asunto(s)
Angioplastia Coronaria con Balón , Aterectomía Coronaria/métodos , Enfermedad de la Arteria Coronaria/cirugía , Stents Metálicos Autoexpandibles/efectos adversos , Anciano , Angioplastia Coronaria con Balón/efectos adversos , Angioplastia Coronaria con Balón/instrumentación , Estudios de Cohortes , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico , Femenino , Francia/epidemiología , Humanos , Efectos Adversos a Largo Plazo , Masculino , Persona de Mediana Edad , Falla de Prótesis , Reoperación/métodos , Estudios Retrospectivos , Resultado del Tratamiento
16.
Entropy (Basel) ; 20(10)2018 Sep 29.
Artículo en Inglés | MEDLINE | ID: mdl-33265834

RESUMEN

We study entanglement properties of generic three-qubit pure states. First, we obtain the distributions of both the coefficients and the only phase in the five-term decomposition of Acín et al. for an ensemble of random pure states generated by the Haar measure on U ( 8 ) . Furthermore, we analyze the probability distributions of two sets of polynomial invariants. One of these sets allows us to classify three-qubit pure states into four classes. Entanglement in each class is characterized using the minimal Rényi-Ingarden-Urbanik entropy. Besides, the fidelity of a three-qubit random state with the closest state in each entanglement class is investigated. We also present a characterization of these classes in terms of the corresponding entanglement polytope. The entanglement classes related to stochastic local operations and classical communication (SLOCC) are analyzed as well from this geometric perspective. The numerical findings suggest some conjectures relating some of those invariants with entanglement properties to be ground in future analytical work.

19.
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA