Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Sci Rep ; 12(1): 2108, 2022 02 08.
Artículo en Inglés | MEDLINE | ID: mdl-35136130

RESUMEN

Assessment of natural background radionuclides emanating from the subsurface geological features was carried out with the use of gamma-ray spectrometry at various locations at one of the secondary school in Canaan land, Ota, Ogun State. The activity concentrations of 226Ra, 232Th and 40K were revealed to be 12.66 ± 0.76-42.33 ± 1.37, 44.96 ± 1.41-128.70 ± 1.56, 31.30 ± 1.18-453.85 ± 2.43 Bq kg-1 respectively. The mean value of 232Th reported higher than the world reference standard of 50 Bq kg-1. Moreover, the stations closest to the school's laboratory were noticed to be prone to more gamma radiations than the other buildings in the school. Similarly, the results of the radiological parameters estimated varied between 86.04-243.7 Bq kg-1, 40.02-115.4 nGy h-1, 0.049-0.142 mSv y-1 and 0.232-0.658 for Raeq, D(out), AEDE and Hex, respectively. Although, the results of the radiological parameters did not exceed the world safe limits, higher values of these parameters were reported at some stations closer to the school laboratory. It can be concluded that the school laboratory is prone to more gamma radiation than the class rooms and the administrative block. Therefore, the laboratory instructors and staff, who spend longer time in the laboratory, are more liable to the health risk that could result from years of exposure to gamma radiation in the laboratory.

2.
Sci Rep ; 11(1): 17555, 2021 09 02.
Artículo en Inglés | MEDLINE | ID: mdl-34475416

RESUMEN

The risk of natural terrestrial radioactivity on human health is often underestimated, and environmental safety awareness is necessary. Hence, this study aims to assess natural sources of gamma radiation emitter in coastal urban-environment using the radiometric technique. The dosage of gamma radiation from a parent radionuclide such as Uranium-238 (238U), Thorium-232 (232Th) and Potassium-40 (40K) and were measured using portable gamma spectroscopy. The result showed that the measured value of 238U activity was between 10.81 [Formula: see text] 0.69 and 46.31 [Formula: see text] 1.43 Bqkg-1. The mean value was estimated to be 35.44 [Formula: see text] 0.97 Bqkg-1 which is slightly higher than the world average. Meanwhile, 232Th activity ranges from 28.42 [Formula: see text] 1.12 to 69.43 [Formula: see text] 1.76 Bqkg-1 with the calculated mean value of 92.57 [Formula: see text] 1.17 Bqkg-1 while 40K activity ranged between 31.30 ± 1.32 and 328.65 ± 2.32 Bqkg-1 with the estimated mean 137.59 [Formula: see text] 2.42 Bqkg-1. Radiological parameters such as radium equivalent (Req), internal hazard (Hint) and external hazard (Hext) assessment were in the range of 66.00 Bqkg-1 to 141.76 Bqkg-1, 0.232 to 0.452 and 0.178 to 0.383, respectively. The measured values of gamma dose-rates ranged between 54.283 ± 0.78 and 117.531 ± 1.14 nGyh-1 with the calculated mean value of 84.770 ± 0.97 nGyh-1.

3.
ScientificWorldJournal ; 2020: 3989563, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32774180

RESUMEN

H2S gas when exposed to metal can be responsible for both general and localized corrosion, which depend on several parameters such as H2S concentration and the corrosion product layer formed. Therefore, the formation of passive film on 316L steel when exposed to H2S environment was investigated using several analysis methods such as FESEM and STEM/EDS analyses, which identified a sulfur species underneath the porous structure of the passive film. X-ray photoelectron spectroscopy analysis demonstrated that the first layer of CrO3 and Cr2O3 was dissolved, accelerated by the presence of H2S-Cl-. An FeS2 layer was formed by incorporation of Fe and sulfide; then, passivation by Mo took place by forming a MoO2 layer. NiO, Ni(OH)2, and NiS barriers are formed as final protection for 316L steel. Therefore, Ni and Mo play an important role as a dual barrier to maintain the stability of 316L steel in high pH2S environments. For safety concern, this paper is aimed to point out a few challenges dealing with high partial pressure of H2S and limitation of 316L steel under highly sour condition for the oil and gas production system.

4.
Sci Rep ; 9(1): 4219, 2019 03 12.
Artículo en Inglés | MEDLINE | ID: mdl-30862825

RESUMEN

Natural radioactivity in coastaline area soil of Ado-Odo/Ota has been carried out to ascertain the presence of radionuclides using gamma-ray spectroscopy (HPGe detector). The result showed that U-238, Th-232 and K-40 ranged from 24 ± 7-49 ± 10; 67 ± 6-120 ± 9 and 88 ± 17-139 ± 20 Bqkg-1 respectively. The radium equivalent for the samples ranged from 132.51 to 230.91 Bqkg-1 with mean value of 185.89 Bqkg-1. The mean value for the gamma dose rate for the soil samples was estimated to be 81.32 nGyh-1. The estimated values of annual effective dose equivalent ranged from 0.61 to 1.07 mSv y-1. The estimation of alpha index representative (Iα) ranged from 0.12 to 0.24 with mean value of 0.21 while the gamma representative index ranged between 0.465 and 0.810. The activity utilization index of the soil samples ranged from 1.09 to 1.89 with mean value of 1.53. The radiological implication in the study area has shown that the soil samples with gamma dose rate value of 89.99 nGyh-1, 94.39 nGyh-1, 97.40 nGyh-1 and 101.04 nGyh-1 respectively are higher than the recommended value of 80 nGyh-1 and may pose health implication for long term exposure.

5.
MethodsX ; 5: 8-19, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29387568

RESUMEN

In this study, we evaluated the activity concentration of natural radionuclides (226Ra, 232Th and 40K) for fifteen (15) different brands of tile samples used for building purposes in Nigeria. The tile samples were analyzed using High purity Germanium gamma detector. The mean activity concentrations of 226Ra, 232Th, and 40K were observed to be 61.1 ±â€¯5.5 Bq/kg, 70.2 ±â€¯6.08 Bq/kg and 514.7 ±â€¯59.8 Bq/kg respectively. Various hazard indices such as absorbed dose rate, external and internal hazard index, annual effective dose rate, Gamma activity Index (Iγ) and Alpha Index (Iα) were calculated. The obtained results showed that the mean radium equivalent activity (Raeq), the absorbed dose rate (D), external and internal hazard index, the annual effective dose (AEDR) equivalent, Gamma activity Index (Iγ) and Alpha Index (Iα) were: 204.42 Bq/kg, 177.61 nGyh-1, 0.55, 0.77, 0.96 mSvyr-1, 0.74 and 0.32 respectively. The average value of radium equivalent obtained in this study is less than that of the recommended value of 370 Bq/kg but the average values of the other radiological hazards for some samples are found to be slightly above international recommended values except Hex, Hin and AEDE which are within the international reference value of unity. The measured concentrations of these radioactive materials were correlated with other previous result obtained from similar tile materials used in other countries and found to be in good agreement with the international standard, however, the tiles are recommended for decoration purposes in Nigeria.

6.
Radiat Prot Dosimetry ; 167(1-3): 160-4, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25920778

RESUMEN

The optimisation of electrokinetic remediation of an alluvial soil, locally named as Holyrood-Lunas from Sri Gading Industrial Area, Batu Pahat, Johor, Malaysia, had been conducted in this research. This particular soil was chosen due to its relatively high level of background radiation in a range between 139.2 and 539.4 nGy h(-1). As the background radiation is correlated to the amount of parent nuclides, (238)U and (232)Th, hence, a remediation technique, such as electrokinetic, is very useful in reducing these particular concentrations of heavy metal and radionuclides in soils. Several series of electrokinetics experiments were performed in laboratory scale in order to study the influence of certain electrokinetic parameters in soil. The concentration before (pre-electrokinetic) and after the experiment (post-electrokinetic) was determined via X-ray fluorescence (XRF) analysis technique. The best electrokinetic parameter that contributed to the highest achievable concentration removal of heavy metals and radionuclides on each experimental series was incorporated into a final electrokinetic experiment. Here, High Pure Germanium (HPGe) was used for radioactivity elemental analysis. The XRF results suggested that the most optimised electrokinetic parameters for Cr, Ni, Zn, As, Pb, Th and U were 3.0 h, 90 volts, 22.0 cm, plate-shaped electrode by 8 × 8 cm and in 1-D configuration order whereas the selected optimised electrokinetic parameters gave very low reduction of (238)U and (232)Th at 0.23 ± 2.64 and 2.74 ± 23.78 ppm, respectively.


Asunto(s)
Electrólisis/métodos , Restauración y Remediación Ambiental/métodos , Residuos Industriales/prevención & control , Metales Pesados/aislamiento & purificación , Radioisótopos/análisis , Contaminantes del Suelo/aislamiento & purificación , Descontaminación/métodos , Malasia , Metales Pesados/química , Eliminación de Residuos/métodos , Contaminantes del Suelo/química
7.
Med J Malaysia ; 68(1): 39-43, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23466765

RESUMEN

RetCam is an excellent screening tool for the detection of retinopathy of prematurity (ROP). However, affordability is a barrier when adopting the use of RetCam in developing countries. We aimed to describe different stages of ROP using ultrasonographic B-scan and to evaluate the association between funduscopic examinations and ultrasonographic B-scan findings in premature neonates with ROP in Malaysia. A descriptive cross sectional study was conducted in 90 eyes of 47 premature neonates with different stages of ROP in three tertiary hospitals in Malaysia. Experienced ophthalmologists performed detailed funduscopic examinations using binocular indirect ophthalmoscopy (BIO). A masked examiner performed a 10 MHz ultrasonographic B-scan evaluation with 12 meridian position images within 48 hours of clinical diagnosis. Data from the clinical examination and ultrasonographic findings were collected and analysed. We recruited 37 eyes (41.1%) with stage 1 ROP, 29 eyes (32.3%) with stage 2, 18 eyes (20.0%) with stage 3, and 3 eyes (3.3%) with stages 4 and 5 based on the clinical assessment. Ultrasonography correctly identified 3 (8.1%) stage 1 eyes, 17 (58.6%) stage 2 eyes, 13 (72.2%) stage 3 eyes, and 3 each (100%) of the stage 4 and 5 eyes. There was a significant association between the funduscopic signs and the ultrasound findings for stage 2 ROP and above (Fisher's exact test, p <0.001). In conclusion, all stages of ROP were detected and described with a 10 MHz ultrasonic B-scan system. A significant association was observed between funduscopic signs and ultrasonographic findings in premature Malaysian neonates with stage 2 ROP and above.


Asunto(s)
Oftalmoscopía , Retinopatía de la Prematuridad , Estudios Transversales , Humanos , Recién Nacido , Recién Nacido de muy Bajo Peso , Malasia , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA