Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Prosthodont ; 2023 Dec 06.
Artículo en Inglés | MEDLINE | ID: mdl-38056598

RESUMEN

PURPOSE: Many elastomeric impressions sent to commercial laboratory dental technicians may include marginal defects. To fabricate accurate restorations, digital technology may be used to merge digital files of defective impressions into a single standard tessellation language (STL) file free of errors. This would save clinicians and patients time and may improve clinical care. The purpose of this study was to compare the accuracy of digital master casts reconstructed from merged STL files of defective impressions with the file of the original defect-free preparations. MATERIAL AND METHODS: Ivorine teeth on a dentoform were prepared to receive a posterior fixed dental prosthesis (FDP) with complete coverage preparations. An impression was made in a stock tray using polyvinyl siloxane (PVS) impression material and an extraoral scanner (E3, 3Shape, Denmark) was used to digitize the impression; this was the reference cast. Wax was used to create defects on the buccal and lingual margins of the preparations. Fifteen PVS impressions were made of the FDP preparations with defects in the mesial and distal margins; another set of 15 PVS impressions was made of FDP preparations with defects in the buccal and palatal margins for a total of 30 impressions. All impressions were digitized using the same extraoral scanner (E3, 3Shape, Denmark). Corresponding STL files were paired and merged, and a master cast was created by eliminating the defects using the scanned data. This master cast was compared to the reference cast using reverse engineering software (Geomagic, Morrisville, NC, USA). The results were expressed as average errors and standard deviations in the master casts relative to the reference cast. To account for the presence of positive and negative values in the data set, in terms of errors, the root mean square (RMS) value was calculated for each sample. RESULTS: The mean average error in the sample was -0.4 µm. The average upper limit of 95% confidence interval was +36.5 µm, while the average lower limit of 95% confidence interval was -37.3 µm. The mean RMS of the errors found was 18.9 µm. CONCLUSIONS: The results of this study indicated that merging digitized definitive impressions to correct marginal defects resulted in master casts with a high level of accuracy relative to the reference cast.

2.
J Prosthodont ; 30(1): 13-18, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33196131

RESUMEN

For most of the last century, conventional complete dentures have been the standard of care and the most common treatment for edentulous patients. Technological advancements in fabrication techniques may significantly reduce the number of office visits required to fabricate complete dentures. Immediate occlusal loading with mandibular full arch prostheses has been extensively researched and is now one of the standards of care for edentulous patients. A clinical technique for converting a mandibular immediate complete denture to an interim full arch, screw-retained fixed prosthesis with novel implant restorative components for immediate loading on four implants is described.


Asunto(s)
Implantes Dentales , Carga Inmediata del Implante Dental , Arcada Edéntula , Tornillos Óseos , Diseño de Prótesis Dental , Prótesis Dental de Soporte Implantado , Dentadura Completa , Estudios de Seguimiento , Humanos , Arcada Edéntula/cirugía , Resultado del Tratamiento
3.
World J Orthop ; 7(1): 55-60, 2016 Jan 18.
Artículo en Inglés | MEDLINE | ID: mdl-26807357

RESUMEN

Calcific tendinitis within the rotator cuff tendon is a common shoulder disorder that should be differentiated from dystrophic calcification as the pathogenesis and natural history of both is totally different. Calcific tendinitis usually occurs in the fifth and sixth decades of life among sedentary workers. It is classified into formative and resorptive phases. The chronic formative phase results from transient hypoxia that is commonly associated with repeated microtrauma causing calcium deposition into the matrix vesicles within the chondrocytes forming bone foci that later coalesce. This phase may extend from 1 to 6 years, and is usually asymptomatic. The resorptive phase extends from 3 wk up to 6 mo with vascularization at the periphery of the calcium deposits causing macrophage and mononuclear giant cell infiltration, together with fibroblast formation leading to an aggressive inflammatory reaction with inflammatory cell accumulation, excessive edema and rise of the intra-tendineous pressure. This results in a severely painful shoulder. Radiological investigations confirm the diagnosis and suggest the phase of the condition and are used to follow its progression. Although routine conventional X-ray allows detection of the deposits, magnetic resonance imaging studies allow better evaluation of any coexisting pathology. Various methods of treatment have been suggested. The appropriate method should be individualized for each patient. Conservative treatment includes pain killers and physiotherapy, or "minimally invasive" techniques as needling or puncture and aspiration. It is almost always successful since the natural history of the condition ends with resorption of the deposits and complete relief of pain. Due to the intolerable pain of the acute and severely painful resorptive stage, the patient often demands any sort of operative intervention. In such case arthroscopic removal is the best option as complete removal of the deposits is unnecessary.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA