Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Saudi J Kidney Dis Transpl ; 31(6): 1263-1272, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33565438

RESUMEN

The evaluation of iron status in dialysis patients provides information essential to the planning of adequate recombinant human erythropoietin treatment. To diagnose iron deficiency in patients undergoing hemodialysis (HD), reticulocyte hemoglobin content and percentage of hypochromic red cells are incorporated into the European best practice guidelines on anemia management in chronic kidney disease (CKD), the mean reticulocyte hemoglobin content (Ret-HE) was proposed as alternatives to standard biochemical tests. Reticulocyte hemoglobin content and percentage of hypochromic red cells are incorporated into the European best practice guidelines on anemia management in CKD. Our aim was to assess the value of Ret-HE parameter, in terms of the sensitivity and specificity for detecting iron deficiency, in HD patients. We studied 50 patients undergoing HD three times weekly , to clarify the accuracy of Ret-HE in diagnosing iron deficiency in dialysis patients, we initially compared Ret-HE with such iron parameters as serum ferritin levels, transferrin saturation, and hypochromic red blood cell (Hypo%) which has been established as indicators of functional iron deficiency. Ret-HE mean value in anemic patients was (25.84 ± 4.23 pg) and had good correlation (P <0.001) between Ret-HE, serum iron, ferritin, transferrin, and transferin saturation in dialysis patients. Receiver operating characteristic curve analysis revealed, values of the area was 0.887, and at a cutoff value of 27.0 pg, a sensitivity of 90.4% and a specificity of 80.8% were achieved. The newly proposed Ret-HE can provide clinicians with information equivalent to iron deficiency anemia markers. Ret-HE is a new parameter that is easily measurable is suggested as reliable parameters for the study of erythropoiesis status in HD patients.


Asunto(s)
Anemia Ferropénica/sangre , Anemia Ferropénica/diagnóstico , Hemoglobinas/metabolismo , Deficiencias de Hierro , Reticulocitos/metabolismo , Anciano , Anciano de 80 o más Años , Femenino , Ferritinas/sangre , Humanos , Hierro/sangre , Sobrecarga de Hierro/prevención & control , Masculino , Persona de Mediana Edad , Curva ROC , Diálisis Renal , Insuficiencia Renal Crónica/terapia , Transferrina/metabolismo
2.
Transplantation ; 91(12): 1386-91, 2011 Jun 27.
Artículo en Inglés | MEDLINE | ID: mdl-21508898

RESUMEN

BACKGROUND: Recurrent glomerulonephritis (GN) remains an important cause of kidney allograft loss and whether rapid discontinuation of steroids (RDS) is associated with a higher risk of recurrence is not known. METHODS: We studied recurrence rate, and graft and patient survival in four groups of recipients: 216 recipients with GN transplanted under RDS (group 1), 978 concurrent non-GN recipients transplanted under RDS (group 2), 260 historic comparator group transplanted for GN between 1994 and 1999 with steroid maintenance (group 3), and 950 recipients who were also transplanted between 1994 and 1999 for non-GN and also maintained on steroids (group 4). Regression analysis adjusting for donor and recipient factors, steroid and sirolimus use, and also GN type was used to address factors associated with recurrent disease. RESULTS: The 1-, 5-, and 7-year recurrence rate in the GN group under RDS was 6.7%, 13.7%, and 19.2% and in historic GN recipients maintained on steroids it was 2.4%, 3.8%, and 5.3%, respectively (P<0.0001). RDS was associated with a higher adjusted risk of recurrent disease for all GN types (hazard ratio 4.86; 95% confidence interval 2.34-10.07; P<0.0001). Graft and patient survival were similar in the two GN groups and both were highest among all groups. Notably, death-censored graft survival was not different among the groups. CONCLUSION: Steroid avoidance may be associated with a higher rate of recurrent GN but no apparent increase in risk of graft loss. This group of recipients needs to be studied more carefully, in larger numbers, and for a longer time period.


Asunto(s)
Glomerulonefritis/etiología , Insuficiencia Renal/diagnóstico , Adulto , Femenino , Glomerulonefritis/mortalidad , Rechazo de Injerto , Supervivencia de Injerto , Humanos , Inmunosupresores/uso terapéutico , Trasplante de Riñón/métodos , Donadores Vivos , Masculino , Persona de Mediana Edad , Recurrencia , Insuficiencia Renal/mortalidad , Insuficiencia Renal/terapia , Riesgo , Esteroides/uso terapéutico , Resultado del Tratamiento
3.
Nephrol Dial Transplant ; 25(5): 1653-61, 2010 May.
Artículo en Inglés | MEDLINE | ID: mdl-20118486

RESUMEN

BACKGROUND: How to best estimate glomerular filtration rate (GFR) in kidney transplant recipients on steroid-free immunosuppression has not been established. METHODS: Within 3 months of transplantation, iothalamate GFR (iGFR) was measured in 107 recipients on steroid-free and 27 on steroid-maintenance immunosuppression. A year later, a second GFR was performed. Serum creatinine was calibrated against a reference laboratory, and GFR was estimated (eGFR) using the re-expressed Cockcroft-Gault equation, eGFRCG; the Mayo Clinic equation, eGFRMC; the Modification of Diet in Renal Disease (MDRD) study equation, eGFRMDRD; and the newly introduced Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) equation. RESULTS: All models overestimated GFR regardless of steroid use or timing of GFR. In those not receiving steroids, eGFRCG was least biased: 1.85 +/- 15.2 ml/min at the first GFR and 0.23 +/- 15.2 ml/min at the second. eGFRMC and eGFRCKD-EPI were most biased and were within 30% of iGFR less than 60% of the time in contrast to eGFRCG which was within 30% of iGFR 80.2% of the time. eGFRMDRD was intermediate in its performance at the first GFR but was comparable to eGFRCG at the second measurement. Importantly, the four models had comparable but poor precision. Exposure to steroids for a whole year did not appreciably alter the models' bias or relative accuracy but resulted in a dramatic fall in their precision, R2 = 0.05-0.12. CONCLUSIONS: GFR prediction equations overestimate measured GFR in recipients on and off steroid regimens. Long-term exposure to steroids results in a marked reduction in the precision of all models. In all, eGFRCG and eGFRMDRD are the two best available models.


Asunto(s)
Corticoesteroides/efectos adversos , Tasa de Filtración Glomerular , Trasplante de Riñón , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA