Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Catheter Cardiovasc Interv ; 90(1): 39-47, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-27651317

RESUMEN

BACKGROUND: In a number of coronary bifurcation lesions, both the main vessel and the side branch (SB) need stent coverage. OBJECTIVES: To analyze the procedural performance and the impact on radiation times (RT) and contrast medium consumption (CMC) of the Axxess™ stent system (Biosensors, Switzerland) treating de novo bifurcation lesions (DBL). METHODS: One hundred and ten consecutive prospectively enrolled cases (Axxess Group) and 110 age, sex, and lesion location matched controls undergoing mandatory (Group A, n = 56) or provisional (Group B, n = 54) SB intervention were analyzed. RESULTS: Although more pre-dilatation was performed in the Axxess Group (92.7% vs. 46.4% [Group A] vs. 24.1% [Group B]), and more stents were used (2.4 vs. 1.2 vs. 1.05), RT and CMC were significantly lower in the Axxess Group [7.9 min/129 ml vs. 14.2 min/209 ml vs. 7.8 min/152 ml; P < 0.001]. Final Thrombolysis In Myocardial Infarction three flow in both branches was significantly more frequent in the Axxess Group (98.2% vs. 94.6% vs. 88.9%; P = 0.02), and post-interventional troponin T elevations were the lowest in the Axxess Group. Eighty one percent of the Axxess-stents could be implanted without technical difficulties. Difficult implantations procedures were mainly related to coronary anatomy. There was no safety concerns (cardiac death, stent-thrombosis) compared to controls. Cumulative 6-months MACE rates were 11% versus 23% versus 25%. TLR rates at 6-months were 5%, 18%, and 15%, respectively. CONCLUSIONS: Axxess bifurcation stent system procedures were associated with significantly less RT and CMC compared to conventional DBL therapy strategies. Difficult coronary anatomy may hinder successful implantation and a learning curve has to be considered. © 2016 Wiley Periodicals, Inc.


Asunto(s)
Fármacos Cardiovasculares/administración & dosificación , Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea/instrumentación , Sirolimus/análogos & derivados , Anciano , Anciano de 80 o más Años , Fármacos Cardiovasculares/efectos adversos , Estudios de Casos y Controles , Medios de Contraste/administración & dosificación , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/mortalidad , Trombosis Coronaria/etiología , Femenino , Alemania , Humanos , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/métodos , Intervención Coronaria Percutánea/mortalidad , Estudios Prospectivos , Diseño de Prótesis , Dosis de Radiación , Exposición a la Radiación , Radiografía Intervencional , Sistema de Registros , Factores de Riesgo , Infarto del Miocardio con Elevación del ST/etiología , Sirolimus/administración & dosificación , Sirolimus/efectos adversos , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA