1.
Hip Int ; 12(3): 263-273, 2002.
Artículo en Inglés | MEDLINE | ID: mdl-28124316

RESUMEN

In this study we have compared the mechanical stability of custom (n=8) and anatomical (n=8) uncemented femoral components, following insertion into human cadaveric femurs, during simulated single leg stance and stair climbing. In the custom group two specimens were excluded from the study due to detachment of the greater trochanter during cyclical loading. As a consequence of their mechanical behaviour both types of stems could be divided into subgroups of "unstable" and "stable" implants. In the course of one thousand loading cycles three anatomical stems and one custom stem migrated more than 1 mm, which was interpreted as mechanical loosening. This difference in rate of mechanical loosening was not significant. However, the majority of the stems were remarkably stable and showed micromotion of less than 18 m and migration of less than 35 m at the proximal implant-bone interface. The corresponding figures for the tip of the stems were 243 m and 170 m, respectively. During torsional loading the custom stems showed less rotatory motion than the anatomical stem (p<0.05). There were no significant differences in the magnitude of cyclical micromotion or migration for the two types of femoral stems. (Hip International 2002; 12: 263-73).

2.
J Bone Joint Surg Br ; 83(6): 921-9, 2001 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-11521940

RESUMEN

We have compared the changes in the pattern of the principal strains in the proximal femur after insertion of eight uncemented anatomical stems and eight customised stems in human cadaver femora. During testing we aimed to reproduce the physiological loads on the proximal femur and to simulate single-leg stance and stair-climbing. The strains in the intact femora were measured and there were no significant differences in principal tensile and compressive strains in the left and right femora of each pair. The two types of femoral stem were then inserted randomly into the left or right femora and the cortical strains were again measured. Both induced significant stress shielding in the proximal part of the metaphysis, but the deviation from the physiological strains was most pronounced after insertion of the anatomical stems. The principal compressive strain at the calcar was reduced by 90% for the anatomical stems and 67% for the customised stems. Medially, at the level of the lesser trochanter, the corresponding figures were 59% and 21%. The anatomical stems induced more stress concentration on the anterior aspect of the femur than did the customised stems. They also increased the hoop strains in the proximomedial femur. Our study shows a consistently more physiological pattern of strain in the proximal femur after insertion of customised stems compared with standard, anatomical stems.


Asunto(s)
Fémur/patología , Prótesis de Cadera , Anciano , Fenómenos Biomecánicos , Cementación , Femenino , Humanos , Masculino , Persona de Mediana Edad
3.
J Bone Joint Surg Br ; 81(1): 143-7, 1999 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-10068022

RESUMEN

Ct and advanced computer-aided design techniques offer the means for designing customised femoral stems. Our aim was to determine the Hounsfield (HU) value of the bone at the corticocancellous interface, as part of the criteria for the design algorithm. We obtained transverse CT images from eight human cadaver femora. The proximal femoral canal was rasped until contact with dense cortical bone was achieved. The femora were cut into several sections corresponding to the slice positions of the CT images. After obtaining a computerised image of the anatomical sections using a scanner, the inner cortical contour was outlined and transferred to the corresponding CT image. The pixels beneath this contour represent the CT density of the bone remaining after surgical rasping. Contours were generated automatically at nine HU levels from 300 to 1100 and the mean distance between the transferred contour and each of the HU-generated contours was computed. The contour generated along the 600-HU pixels was closest to the inner cortical contour of the rasped femur and therefore 600 HU seem to be the CT density of the corticocancellous interface in the proximal part of cadaver femora. Generally, femoral bone with a CT density beyond 600 HU is not removable by conventional reamers. Thus, we recommend the 600 HU threshold as one of several criteria for the design of custom femoral implants from CT data.


Asunto(s)
Prótesis de Cadera , Tomografía Computarizada por Rayos X , Adulto , Anciano , Anciano de 80 o más Años , Cadáver , Fémur , Humanos , Persona de Mediana Edad , Diseño de Prótesis
4.
J Orthop Res ; 15(6): 927-31, 1997 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-9497820

RESUMEN

Two conflicting theories exist concerning the stress pattern for the proximal lateral aspect of the human femur. According to the classic theory of Pauwels, a bending moment on the femur leads to compression medially and to tension laterally. The alternative theory is that muscle forces contribute to a moment-free loading of the femur, with both the medial and lateral cortices subjected to compression. To examine these theories, we measured the strain at the external surface of the proximal lateral aspect of the femur of two female patients undergoing surgery for "snapping hip syndrome." During the surgical procedure, a strain-gauge rosette was bonded to the lateral aspect of the femur and the cortical strains were monitored while the patient performed a series of activities. In both patients, principle tensile strain increased significantly during one-legged stance, walking, and stair climbing as compared with that during two-legged stance. During each loading situation, the principal tensile strain was aligned within 22 degrees to the longitudinal femoral axis. Dynamic strain measurements consistently revealed tensile axial strain at the lateral aspect of the femur during each activity. The present study supports the classic bending theory of Pauwels and demonstrates that the proximal lateral aspect of the femur is subjected to tension during the stance phase of gait.


Asunto(s)
Cabeza Femoral/fisiopatología , Articulación de la Cadera/fisiopatología , Artropatías/fisiopatología , Resistencia a la Tracción/fisiología , Adulto , Fenómenos Biomecánicos , Femenino , Articulación de la Cadera/cirugía , Humanos , Artropatías/cirugía , Locomoción/fisiología , Persona de Mediana Edad , Postura/fisiología , Estrés Mecánico
5.
Skeletal Radiol ; 24(2): 105-9, 1995 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-7747174

RESUMEN

Both computed tomography (CT) and ultrasonography have been used successfully to estimate the femoral anteversion (AV) angle. In this study, AV angles in 20 human adult femurs were determined by ultrasonography and CT and the measurements compared. On CT the real AV angle was measured as the angle between the head-neck centreline and the posterior condylar plane. In addition, the angle between the anterior head-trochanter (HT) tangent and the posterior condylar plane was determined. The latter angle was also measured by ultrasonography using the tilted transducer technique. The mean interobserver variation in the ultrasound measurements was 1.9 degrees. We found ultrasonography to correlate very well with CT, both when comparing with the HT angle (r = 0.95) and with the AV angle (r = 0.93). The HT angle was on average 4 degrees greater than the AV angle. In this study the accuracy of ultrasonography was +/- 5 degrees and the method is recommended for screening in patients with rotational disorders of the femur.


Asunto(s)
Fémur/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Adulto , Humanos , Ultrasonografía