1.
Gait Posture ; 40(3): 333-40, 2014 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-24984692

RESUMEN

The purpose of this study was to systematically review the current literature to determine the effect of a femoral derotation osteotomy (FDRO) on hip and pelvic rotation kinematics during gait compared to no intervention in children with spastic cerebral palsy (CP). We performed a systematic search for prospective and retrospective cohort studies of children with CP, who were treated with a FDRO, and were assessed with pre and post surgery three-dimensional gait analysis. Medline, CINAHL, EMBASE, the Cochrane Library and Web of Science were searched up to December 2013. Data sources were prospective and retrospective studies. Mean differences were calculated on pooled data for both pelvic and hip rotation kinematics. Thirteen of 196 articles met the inclusion criteria (5 prospective, 8 retrospective). All included studies were of sufficient quality for meta-analysis as assessed using a customised version of the STROBE checklist. Meta-analysis showed that FDRO significantly reduced pelvic retraction by 9.0 degrees and hip internal rotation by 17.6 degrees in participants with unilateral CP involvement and hip internal rotation by 14.3 degrees in participants with bilateral CP involvement. Pelvic symmetry in children with unilateral spastic CP is significantly improved by FDRO. Patients with bilateral involvement do not improve their transverse plane pelvic rotation profiles during gait as a result to FDRO, although this result should be interpreted with caution due to the heterogeneous nature of these participants and of the methods used in the studies assessed.


Asunto(s)
Parálisis Cerebral/cirugía , Fémur/cirugía , Marcha/fisiología , Hemiplejía/cirugía , Cadera/cirugía , Osteotomía/métodos , Fenómenos Biomecánicos , Parálisis Cerebral/fisiopatología , Niño , Fémur/fisiopatología , Hemiplejía/fisiopatología , Cadera/fisiopatología , Articulación de la Cadera/fisiopatología , Articulación de la Cadera/cirugía , Humanos , Rotación
2.
Am J Health Syst Pharm ; 70(24): 2185-98, 2013 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-24296841

RESUMEN

PURPOSE: Published stability and compatibility data on a growing array of solutions used for antimicrobial lock therapy (ALT) are reviewed. SUMMARY: ALT involves the instillation of a highly concentrated antimicrobial, often in combination with an anticoagulant, into a central venous catheter (CVC) lumen; this technique is often used for prophylaxis after CVC insertion or as an adjunctive treatment in cases of central line-associated bloodstream infection (CLABSI) if catheter removal is not feasible. Optimal selection of stable and compatible antimicrobials and additives can maximize catheter dwell times, streamline pharmacy compounding practices, and help ensure patient safety. Of 98 articles on ALT solutions identified in a literature search, 17 met the prespecified criteria for the use of validated stability and compatibility methodology. Antimicrobials active against common CLABSI pathogens that may be appropriate for ALT include cefazolin, cefotaxime, ceftazidime, ciprofloxacin, daptomycin, gentamicin, linezolid, telavancin, ticarcillin-clavulanic acid, and vancomycin; validated data demonstrate the stability of these agents in solution with heparin or nonheparin anticoagulants over 72-96 hours or longer. Other antifungal agents and antiinfectives (e.g., ethyl alcohol) have been used in specific patients and ALT situations. The prolonged stability of several antimicrobial-additive combinations may allow for extended dwell times and less frequent lock solution exchanges. CONCLUSION: Pharmacists' knowledge of diverse combinations of antimicrobial agents and additives in lock solutions, including several shown to be stable and compatible for extended periods, can help expand and optimize the use of ALT in both treatment and prophylactic modalities.


Asunto(s)
Antiinfecciosos/administración & dosificación , Infecciones Relacionadas con Catéteres/prevención & control , Cateterismo Venoso Central/métodos , Heparina/administración & dosificación , Antiinfecciosos/química , Anticoagulantes/administración & dosificación , Anticoagulantes/química , Cateterismo Venoso Central/efectos adversos , Composición de Medicamentos , Incompatibilidad de Medicamentos , Estabilidad de Medicamentos , Heparina/química , Humanos , Factores de Tiempo
3.
Magn Reson Imaging ; 31(10): 1690-4, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24094811

RESUMEN

PURPOSE: To assess the feasibility of measuring pulmonary artery (PA) pulse wave velocity (PWV) in children breathing ambient air and 12% oxygen. METHODS: Velocity-encoded phase-contrast MR images of the PA were acquired in 15 children, aged 9-12years, without evidence of cardiac or pulmonary diseases. PWV was derived as the ratio of flow to area changes during early systole. Each child was scanned twice, in air and after at least 20minutes into inspiratory hypoxic challenge. Intra-observer and inter-observer variability and repeatability were also compared. RESULTS: PA PWV, which was successfully measured in all subjects, increased from 1.31±0.32m/s in air to 1.61±0.58m/s under hypoxic challenge (p=0.03). Intra- and inter-observer coefficients of variations were 9.0% and 15.6% respectively. Good correlation within and between observers of r=0.92 and r=0.72 respectively was noted for PA PWV measurements. Mean (95% limit of agreement) intra- and inter-observer agreement on Bland-Altman analysis were -0.02m/s (-0.41-0.38m/s) and -0.28m/s (-1.06-0.49m/s). CONCLUSION: PA PWV measurement in children using velocity-encoded MRI is feasible, reproducible and sufficiently sensitive to detect differences in PA compliance between normoxia and hypoxia. This technique can be used to detect early changes of PA compliance and monitor PAH in children.


Asunto(s)
Hipoxia/fisiopatología , Interpretación de Imagen Asistida por Computador/métodos , Angiografía por Resonancia Magnética/métodos , Arteria Pulmonar/fisiopatología , Circulación Pulmonar , Flujo Pulsátil , Análisis de la Onda del Pulso/métodos , Velocidad del Flujo Sanguíneo , Niño , Estudios de Factibilidad , Femenino , Humanos , Hipoxia/diagnóstico , Masculino , Proyectos Piloto , Arteria Pulmonar/anatomía & histología , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Rigidez Vascular
4.
Eur J Echocardiogr ; 12(3): 247-54, 2011 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-21257626

RESUMEN

AIMS: Myocardial deformation imaging is now used to assess regional ventricular function in infants but their small size presents particular technical challenges. We therefore investigated the determinants of reproducibility of myocardial longitudinal strain (ε) in term and preterm infants, in order to determine optimal technical settings. METHODS AND RESULTS: Repeated longitudinal ε measurements of the mid-segments of the septum, and the left and right ventricular free walls, were performed using five different computation distances (CDs; also called strain length) in 20 infants. The coefficients of variation (CV) were calculated for each CD. Overall, ε measurements were most reproducible with a CD of 6 mm (CV 11.7%). In preterm infants (<34 weeks gestation; mean ± SD diastolic LV length, 20.3 ± 3.5 mm), ε measurements were most reproducible with CD of 6 mm (CV 7.2%); in term infants (>37 weeks gestation; mean ± SD diastolic LV length, 29.6 ± 3.0 mm), ε measurements were most reproducible with CD of 10 mm (CV 13.2%). The reproducibility of measuring ε increased with higher frame rates, from CV of 17.3% at frame rates <180 per s to 11.7% for frame rates >180 per s and 9.6% for rates >248 per s. CONCLUSION: In newborn infants, tissue Doppler loops should be acquired at frame rates above 180 per s. Myocardial deformation analysis of preterm infants should be performed using a CD of 6 mm, whereas a CD of 10 mm is more reproducible in term infants.


Asunto(s)
Ecocardiografía Doppler de Pulso , Ventrículos Cardíacos/diagnóstico por imagen , Interpretación de Imagen Asistida por Computador , Recien Nacido Prematuro , Análisis de Varianza , Estudios de Cohortes , Femenino , Ventrículos Cardíacos/fisiopatología , Humanos , Recién Nacido , Masculino , Contracción Miocárdica/fisiología , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Estadísticas no Paramétricas , Nacimiento a Término , Función Ventricular Izquierda/fisiología , Función Ventricular Derecha/fisiología
5.
Respir Med ; 104(8): 1171-8, 2010 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-20185285

RESUMEN

BACKGROUND: Cardiovascular manifestations in COPD include increased arterial stiffness, ischaemic heart disease, chronic heart failure and cor pulmonale. We hypothesised that sub-clinical right (RV) and left ventricular (LV) dysfunction occurs in patients with COPD, related to the severity of airflow obstruction, arterial stiffness and systemic inflammation. METHODS: Thirty six patients and 14 controls, all free of overt cardiovascular disease underwent tissue Doppler echocardiography, spirometry, measurement of aortic pulse wave velocity (PWV) and venous sampling for inflammatory markers. RESULTS: Mean LV myocardial strain and strain rate were less in patients than controls, p<0.05. LV isovolumic relaxation time (IVRT) was prolonged in patients (125+/-15.2ms) compared with controls (98.2+/-21.1ms), p<0.01, indicating LV diastolic dysfunction. The RV free wall strain and strain rate were less in patients than controls, both p<0.05, indicating RV systolic dysfunction. Patients had sub-clinical pulmonary arterial hypertension with a greater RV myocardial relaxation time and Tei index, both p<0.01. Patients with mild airways obstruction had LV and RV dysfunction and evidence of increased RV afterload compared with controls. In multivariate analyses aortic PWV predicted LV IVRT, p<0.01, while FEV(1) predicted RV Tei index and myocardial relaxation time, both p<0.01. CONCLUSIONS: Patients with COPD have sub-clinical left ventricular dysfunction related to arterial stiffness, and right ventricular dysfunction related to airways obstruction. Both right and left ventricular dysfunction are present in patients with mild airways obstruction suggesting that cardiac co-morbidities commence early in the development of COPD.


Asunto(s)
Velocidad del Flujo Sanguíneo/fisiología , Enfermedad Pulmonar Obstructiva Crónica/fisiopatología , Disfunción Ventricular Izquierda/fisiopatología , Disfunción Ventricular Derecha/fisiopatología , Anciano , Composición Corporal/fisiología , Estudios de Casos y Controles , Ecocardiografía Doppler , Femenino , Humanos , Masculino , Enfermedad Pulmonar Obstructiva Crónica/complicaciones , Enfermedad Pulmonar Obstructiva Crónica/diagnóstico por imagen , Medición de Riesgo , Encuestas y Cuestionarios , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Izquierda/etiología , Disfunción Ventricular Derecha/diagnóstico por imagen , Disfunción Ventricular Derecha/etiología
6.
Eur J Echocardiogr ; 11(1): 44-50, 2010 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-19889652

RESUMEN

AIMS: Myocardial velocity imaging has been validated in adults for assessment of ventricular function and indirect indices of pulmonary arterial pressure. To establish whether it could also be used in infants, we investigated the reproducibility of myocardial velocities and deformation indices in term and preterm neonates. METHODS AND RESULTS: Myocardial velocity loops acquired from 16 infants were analysed by four observers for inter-observer variability, and re-analysed after 6 months by one observer for intra-observer variability. For myocardial velocities, the coefficients of variation (CVs) for the left ventricle (LV) were 10-11 (intra-observer) and 14-20% (inter-observer) and for the right ventricle (RV) 15-19 and 18-24%, respectively. Reproducibility for annular displacements was <13% (intra-observer) and <18% (inter-observer). CVs for LV strain were 14-17 (intra-observer) and 36-43% (inter-observer) and for RV 19-24 and 25-37%. CVs for isovolumic acceleration were in general >40%. In comparison, the CVs for blood pool indices were 3-15%. CONCLUSION: Intra-observer reproducibility for myocardial velocity and deformation indices in neonates is adequate for these parameters to be used in clinical research. Inter-observer reproducibility is sub-optimal suggesting that these measurements should be used in clinical practice with caution. Myocardial acceleration, a marker of contractile function, was poorly reproducible.


Asunto(s)
Corazón/fisiología , Hemodinámica , Recién Nacido/fisiología , Recien Nacido Prematuro/fisiología , Contracción Miocárdica , Intervalos de Confianza , Ecocardiografía Doppler en Color , Indicadores de Salud , Tabiques Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Lactante , Reproducibilidad de los Resultados , Sístole , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/patología , Función Ventricular Izquierda/fisiología , Función Ventricular Derecha/fisiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA