Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
IEEE J Transl Eng Health Med ; 8: 1800311, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32617198

RESUMEN

BACKGROUND: Digital radiography devices are still the gold standard for diagnosis or therapy guidance in medicine. Despite the similarities between all direct digital x-ray systems, researchers and new companies face significant challenges during the development phase of innovative x-ray devices; each component is manufactured independently, guidance towards device integration from manufacturers is limited, global standards for device integration is lacking. METHOD: In scope of this study a plug-integrate-play (PIP) conceptual model for x-ray imaging system is introduced and implemented as an open hardware platform, SyncBox. The researchers are free to select each individual device component from different vendors based on their intended application and target performance are utilized in criteria. RESULT: As its first implementation, SyncBox and its platform a full body high resolution radiographic scanner that employs a novel TDI digital detector. CONCLUSION: We believe that SyncBox has a potential for introducing an open source hardware platform to x-ray equipment design.

2.
J Digit Imaging ; 33(3): 708-721, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-31845123

RESUMEN

A device-independent software package, named iBEX, is developed to accelerate the research and development efforts for X-ray imaging setups such as chest radiography, linear and multidirectional tomography, and dental and skeletal radiography. Its extension mechanism makes the software adaptable for a wide range of digital X-ray imaging hardware combinations and provides capabilities for researchers to develop image processing plug-ins. Independent of the X-ray sensor technology, iBEX could integrate with heterogeneous communication channels of digital detectors. iBEX is a freeware option for preclinical and early clinical testing of radiography devices. It provides tools to calibrate the device, integrate to health information infrastructure, acquire image, store studies on local storage, and send them to Picture Archiving and Communication System (PACS). iBEX is a unique open-source project bringing X-ray imaging devices' software into the scope of the open-source community to reduce the X-ray scanners' research effort, potentially increase the image quality, and cut down the production and testing costs of radiography devices.


Asunto(s)
Intensificación de Imagen Radiográfica , Sistemas de Información Radiológica , Humanos , Procesamiento de Imagen Asistido por Computador , Programas Informáticos , Tomografía Computarizada por Rayos X
3.
Transplant Proc ; 47(5): 1326-30, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-26093711

RESUMEN

BACKGROUND: Pre-transplant sensitization to human leukocyte antigens (HLA) is a risk factor for graft failure. The purpose of the current single-center study was to evaluate humoral immune response to HLA antigens and the possible relationship between anti-HLA antibody titer and autoimmune disorders in renal transplant candidates. METHODS: A total of 435 renal transplant candidates were analyzed; 50 sensitized patients were enrolled in this study. The HLA typing was performed by use of enzyme-linked immunoassay combined with Luminex technology. The patients were questioned for clinical evidence of hypothyroidism and systemic lupus erythematosus (SLE) and investigated for anti-nuclear antibody (ANA), anti-double-stranded DNA (anti-dsDNA), anti-thyroglobulin (anti-TG), anti-thyroid peroxidase (anti-TPO) antibodies, and thyroid function tests. RESULTS: Among 50 patients with positive panel reactive antibody, 24 (48%) were positive for class I and negative for class II, 12 (24%) were negative for class I and positive for class II, and 14 (28%) were positive for both classes I and II. The specificities of anti-HLA antibodies-A23, A68, A69, B27, B49, DR6, and DR8-were the most frequent. ANA and anti-dsDNA antibodies were not correlated with either clinical symptoms of SLE or anti-HLA antibody titer of renal transplant candidates. Similarly, anti-TG and anti-TPO antibodies were not correlated with clinical hypothyroidism or anti-HLA antibody titer. CONCLUSIONS: Our data have demonstrated the profile of anti-HLA antibodies in patients who were on the renal transplant waiting list in Turkey. The most frequent specificities of anti-HLA antibodies were A23, A68, A69, B27, B49, DR6, and DR8. There was no association between anti-HLA antibody titer and clinical and laboratory evidence of SLE and hypothyroidism.


Asunto(s)
Antígenos HLA/inmunología , Hipotiroidismo/inmunología , Inmunidad Humoral/fisiología , Fallo Renal Crónico/inmunología , Trasplante de Riñón , Lupus Eritematoso Sistémico/inmunología , Adulto , Anticuerpos Antinucleares/inmunología , Autoanticuerpos , Femenino , Antígenos de Histocompatibilidad Clase I/inmunología , Antígenos de Histocompatibilidad Clase II/inmunología , Humanos , Fallo Renal Crónico/cirugía , Masculino , Persona de Mediana Edad , Turquía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA